A musculoskeletal simulation and 3D viewer of the human right hand, wrist and forearm, for non-commercial research and education.
Not a medical device. It is a generic model, not patient-specific, and it is not clinically validated. Outputs are model estimates. Read the limitations before using any result.
Recorded runs played back in the viewer. Rendered from the MoBL-ARMS-derived geometry, which is non-commercial and is not stored in this repository.
- Simulates the hand with MuJoCo (23 joints, 44 muscle actuators: 39 from MyoHand, 5 added from published cadaver data), the only physics in the project.
- Runs repeatable tasks from configuration files and records joint angles, activations, muscle forces, tendon lengths and contact forces, with units and provenance.
- Plays recorded runs in a Godot 4 viewer with selectable bones and muscles, activation bars, a joint plot, keyboard control and validity warnings. The viewer contains no physics.
- Reports what the model does not contain, in the documents and in the viewer.
MyoSim (pinned, not bundled) + BioHand patches (data/patches/)
|
MuJoCo model ---> Python: simulation/, biomechanics/, scripts/
| telemetry JSON/CSV (schemas/)
v
Blender (local GLB) --> Godot viewer (visualisation only)
See ARCHITECTURE.md and COORDINATE_SYSTEM.md.
Full steps, including the viewer: INSTALL_WINDOWS.md.
py -3.11 -m venv .venv.venv/Scripts/python.exe -m pip install -r requirements-lock.txt.venv/Scripts/python.exe -m pip install --no-deps -e .git clone https://github.com/MyoHub/myo_sim.git third_party/myo_simgit -C third_party/myo_sim checkout 93b0ca8f4ec90c9899ee7f05fee561e9911da91b.venv/Scripts/python.exe -m pytest -vUse the API:
from simulation.api import BioHandSession
session = BioHandSession()
session.reset({"mcp2_flexion_r": 0.5}) # radians, range-checked
session.set_controls({"FDP2_r": 0.4}) # excitation 0..1
session.step(250)
frame = session.frame() # valid against schemas/telemetry_frame.schema.jsonThe 3D viewer needs a local build, because its bone geometry is non-commercial and not in this repository. Follow INSTALL_WINDOWS.md, section 5.
Or the command line: scripts/biohand.py list-tasks | inventory | run-task <id>. Tasks and what they show: DEMO_SCENARIOS.md.
MyoHand from MyoSim, pinned to commit 93b0ca8f, plus five documented patches applied at build time. Upstream files are never edited.
| Patch | What it changes | Basis | Status |
|---|---|---|---|
wrist_rom_v1 |
Wrist flexion ±70°; deviation 25° ulnar / 10° radial | MoBL-ARMS source values | provisional |
muscle_fixes_v1 |
EDC5 force; RI2 path; lengthrange of 8 muscles |
Source value; consistency with sibling muscles; MuJoCo's definition | provisional |
limit_stiffness_v1 |
Joint-limit stiffness | Numerical setting (2 × timestep), not physiology | provisional |
thumb_intrinsics_v1 |
Adds APB, FPB (2 heads), ADP (2 heads) | One cadaver specimen (Mirakhorlo et al. 2016), mapped by rule; force = PCSA × specific tension | provisional |
passive_stiffness_v1 |
Joint springs | Measured for wrist, forearm, index MCP; assumed for the thumb; estimated for MCP 3–5 | provisional |
moment_arm_calibration_v1 is optional and off by default: it is tuned to the validation data, so it is not validation.
Results from the phase reports:
- Verified as software: forward kinematics matches an independent implementation; inverse dynamics matches forward dynamics; tasks repeat bit for bit; viewer poses match MuJoCo.
- Compared with published data (P8 report): wrist moment arms have the right sign for 12 of 12 measured values, but only 8 of 12 are within 2 SD, and most are overestimated. Index MCP values agree in 10 of 12 comparisons.
- Tasks: 8 of 8 pass their numerical criteria, with caveats. The
pinchtask reaches only about 0.8 N, is unsteady and is fragile against small parameter changes. Therest_neutraltask passes at 4 s and fails at the original 2 s. See the fixes report. - Not validated: forces, timing, EMG and motion trajectories. See the status below.
simulation/: model loading, patches, kinematics, muscles, tasks, API, extension point.biomechanics/: coordinate frames and rigid-body math.data/: glossary, patches, task configurations, validation references, provenance.schemas/: versioned telemetry format.scripts/: audits, evidence generation (reproduce_all.py) and the CLI.godot_app/: viewer.blender/: asset pipeline and visual-to-physics mapping.docs/: specifications and analysis.reports/: evidence per phase.tests/: test suite.third_party/,build/,godot_app/local_assets/(gitignored): upstream models and local builds, never committed.
Version 0.1.0 is a pre-release. CI runs the tests from a clean install on Windows and Linux. The 3D viewer is only tested on one Windows machine. Contributions: CONTRIBUTING.md.
- BioHand's own code is under the MIT licence.
- That licence does not cover the model data. MyoHand is derived from the MoBL-ARMS model, which is licensed for non-commercial use only. Commercial use needs a commercial licence from its owners. No MyoSim or SimTK file is included here. See the licence report and third-party notices.
- Publications using this software with the model must cite Saul et al. 2015 and McFarland et al. 2019 (MoBL-ARMS licence terms). See CITATION.cff and REFERENCES.md.