Describe the bug
A freshly built production LogMonitor.exe captures logs successfully, but exits with access violation 0xC0000005 (signed process exit code -1073741819) when its monitored child finishes normally.
This was observed on unmodified main at 42247c6a23f65ae8e3c4f2d483812972cda1ec6f, with Event Log, File, Process, and ETW monitoring enabled together. The final run captured all four sources without LogMonitor error diagnostics before shutdown.
Shutdown was requested by creating a file that the child checks. The child printed demo generator stopped normally and returned from its main function. No Docker termination signal, Ctrl+C, forced process termination, or historical Event Log replay was involved in this run.
Configuration
- Tool: production Log Monitor executable, file version
2.1.1.0. - Source commit:
42247c6a23f65ae8e3c4f2d483812972cda1ec6f. - Build: clean native MSBuild solution build, x64 Release, checked-in C++14 defaults.
- Host: Windows 11 Enterprise N, version
10.0.26300, build26300, 64-bit; elevated execution. - Child: Python 3.12 generating local file writes, stdout/stderr, short-lived
cmd.exechildren, andlocalhostDNS lookups. - LogMonitor stdout/stderr were redirected to local files.
- Executable SHA256:
9204D54197D06A5C54D9A5FBAD19A3131726E8CA7DD0E8C2393474C8E8684BF8.
Observed reproduction
-
Build the production executable from the commit above.
-
Create an isolated directory without spaces, with
input,input\worker, andoutputsubdirectories. -
Configure all four source types as shown below. Set the File source's absolute directory to the local
inputdirectory. -
Launch LogMonitor with the Python child shown below, using an absolute
/Configpath and redirecting LogMonitor's stdout/stderr to files:LogMonitor.exe /Config C:\Temp\LogMonitorShutdownRepro\LogMonitorConfig.json python.exe -u C:\Temp\LogMonitorShutdownRepro\generate_activity.py -
Allow records from all four sources to arrive, then create
stop.requestbeside the Python script:New-Item 'C:\Temp\LogMonitorShutdownRepro\stop.request' -ItemType File -Force
-
Observe the child's normal-stop message, followed by LogMonitor exiting with
0xC0000005. Windows Application Error event 1000 also records the access violation.
The paths above are normalized examples. This describes the observed combined-source reproduction, not a minimized reproducer; the minimum failing source combination has not yet been isolated.
Final configuration (local path normalized)
{
"LogConfig": {
"logFormat": "JSON",
"sources": [
{
"type": "EventLog",
"startAtOldestRecord": false,
"eventFormatMultiLine": false,
"channels": [
{ "name": "Application", "level": "Warning" },
{ "name": "System", "level": "Warning" }
]
},
{
"type": "File",
"directory": "C:\\Temp\\LogMonitorShutdownRepro\\input",
"filter": "*.log",
"includeSubdirectories": true,
"includeFileNames": true,
"waitInSeconds": 0
},
{ "type": "Process" },
{
"type": "ETW",
"eventFormatMultiLine": false,
"providers": [
{
"providerName": "Microsoft-Windows-DNS-Client",
"providerGuid": "1c95126e-7eea-49a9-a3fe-a378b03ddb4d",
"level": "Verbose",
"keywords": "0x0"
}
]
}
]
}
}Child activity generator used in the final run
Save as generate_activity.py beside the configuration. The input and input\worker directories must already exist, and stop.request must not exist before starting. The script writes one clearly labeled Application WARNING event using the Windows EventCreate source.
import ctypes
from ctypes import wintypes
from datetime import datetime, timezone
import json
import os
from pathlib import Path
import socket
import subprocess
import sys
import time
ROOT = Path(__file__).resolve().parent
STOP = ROOT / "stop.request"
LOGS = (ROOT / "input" / "application.log", ROOT / "input" / "worker" / "worker.log")
def main():
sys.stdout.reconfigure(encoding="utf-8", line_buffering=True)
sys.stderr.reconfigure(encoding="utf-8", line_buffering=True)
kernel32 = ctypes.WinDLL("kernel32", use_last_error=True)
kernel32.OpenProcess.argtypes = (wintypes.DWORD, wintypes.BOOL, wintypes.DWORD)
kernel32.OpenProcess.restype = wintypes.HANDLE
kernel32.WaitForSingleObject.argtypes = (wintypes.HANDLE, wintypes.DWORD)
kernel32.WaitForSingleObject.restype = wintypes.DWORD
kernel32.CloseHandle.argtypes = (wintypes.HANDLE,)
kernel32.CloseHandle.restype = wintypes.BOOL
parent_pid = os.getppid()
parent = kernel32.OpenProcess(0x00100000, False, parent_pid)
if not parent:
raise ctypes.WinError(ctypes.get_last_error())
def parent_alive():
result = kernel32.WaitForSingleObject(parent, 0)
if result == 0xFFFFFFFF:
raise ctypes.WinError(ctypes.get_last_error())
return result == 0x102
def stopping():
return STOP.exists() or not parent_alive()
try:
(ROOT / "generator.json").write_text(
json.dumps(
{
"pid": os.getpid(),
"parent_pid": parent_pid,
"started_at": datetime.now(timezone.utc).isoformat(),
},
indent=2,
),
encoding="utf-8",
)
print(f"demo generator started run={ROOT.name} pid={os.getpid()}")
time.sleep(3)
if stopping():
return
subprocess.run(
[
str(Path(os.environ["SystemRoot"]) / "System32" / "eventcreate.exe"),
"/L", "APPLICATION",
"/SO", "EventCreate",
"/T", "WARNING",
"/ID", "777",
"/D", f"LogMonitor local demo startup probe run={ROOT.name}",
],
check=True,
)
iteration = 0
while not stopping():
iteration += 1
stamp = datetime.now(timezone.utc).isoformat()
for index, path in enumerate(LOGS, start=1):
with path.open("a", encoding="utf-8", newline="\n") as log:
log.write(
f"{stamp} demo file={index} iteration={iteration} run={ROOT.name}\n"
)
print(f"{stamp} demo stdout iteration={iteration}")
print(f"{stamp} demo stderr iteration={iteration}", file=sys.stderr)
addresses = socket.getaddrinfo(
"localhost", 80, socket.AF_INET, socket.SOCK_STREAM
)
print(f"demo localhost lookup iteration={iteration} results={len(addresses)}")
subprocess.run(
[
str(Path(os.environ["SystemRoot"]) / "System32" / "cmd.exe"),
"/d", "/c", f"echo demo child-process iteration={iteration}",
],
check=True,
)
for _ in range(10):
if stopping():
break
time.sleep(0.2)
if parent_alive():
print("demo generator stopped normally")
time.sleep(0.5)
finally:
if not kernel32.CloseHandle(parent):
raise ctypes.WinError(ctypes.get_last_error())
if __name__ == "__main__":
main()Actual results
The same access-violation exit code occurred in 4/4 observed combined-source runs on this host. Event Log, File, and Process sources remained enabled while the ETW provider selection changed:
| Run | ETW providers | LogMonitor exit code |
|---|---|---|
| 1 | Kernel-Process + DNS-Client | 0xC0000005 |
| 2 | PowerShell + DNS-Client | 0xC0000005 |
| 3 | User-Diagnostic + DNS-Client | 0xC0000005 |
| 4 | DNS-Client only | 0xC0000005 |
This does not establish that ETW is the cause or that any individual source is sufficient to trigger the crash.
The final run captured:
| Source | Records |
|---|---|
| Process | 428 |
| ETW | 1,831 |
| File | 212 |
| EventLog | 1 |
- No
[LOGMONITOR] ERROR:diagnostics appeared during the final capture. - The child's normal-stop message was present; no Python traceback was present.
- The final run used
startAtOldestRecord: false, so it did not replay the historical Event Log backlog. - The monitor, generator, and capture wrapper had all exited after shutdown; no
Log Monitor ETW Sessionremained active.
Sanitized Windows Application Error event 1000 from the final run:
Time (UTC): 2026-11-11T19:31:40.6117467Z
Faulting application: LogMonitor.exe
Application version: 2.1.1.0
Faulting module: LogMonitor.exe
Module version: 2.1.1.0
Exception code: c0000005
Faulting offset: 0000000000004331
Captured process exit: -1073741819
The first run also recorded offset 0x4331. A debugger stack/crash dump has not been collected for these reproductions; the faulting offset alone does not establish the root cause.
Expected behavior
After a monitored child finishes normally, LogMonitor should shut down its monitors safely and return the child's exit code rather than terminate with an access violation.
Additional context / related issues
- [BUG] Native test run crashes with 0xC0000005 after TestStartAtOldestRecord passes #238 tracks a native test-host crash after historical Event Log replay. This report concerns the production executable after normal child completion, with replay disabled, on a later
maincontaining the EventMonitor shutdown work. - [BUG] Access Violation (Exception code: 0xc0000005) when running LogMonitor.exe #199 reports a
2.1.0container/startup access violation. The matching exception code alone does not establish a common cause. - STDOUT propagation is broken after termination signal #169 tracks loss of child stdout after an external termination signal. No external termination signal was used in the final reproduction here.
- [BUG] After logs are retrieved by LogMonitor.exe it crashes without any error message #187 was closed after its reporter confirmed that moving to
2.1.1stopped the previously reported constant crashes.
No existing report reviewed clearly describes this current-main normal-child-exit scenario. These references are related reports, not a claim that their root causes match.
The local executable provenance, configurations, generator/capture scripts, exit metadata, and captured output have been retained. Raw host Event Log and DNS payloads are intentionally not included in this public report. No production source changes were made while collecting this evidence.
Activity
bobsira commentedon Nov 13, 2026
Resolution: fixed by #250
Merged into
mainas 8940d8a.The native debugger confirmed a shutdown-lifetime bug: the ETW worker was still using the function-local
c_DecodingSourceToStringtable inEtwMonitor::FormatMetadataafter CRT teardown had destroyed it. The main thread was stopping ETW from the global monitor's atexit destructor, which could deliver pending events to that worker.The fix explicitly destroys the ETW, file, and Event Log monitors before
wmainreturns, while their formatter tables are still alive. It preserves the existing monitor destruction order and the child's exit code.Validation included production-executable regressions that reproduce
0xC0000005on signed RC2, followed by 18/18 repeated passing cases across native x64, native x86, and CMake x64. Six four-source runs also passed with child exit codes 0 and 37, retaining output from all four sources without error diagnostics. The regression tests are included in #250.The follow-up investigation of #248 confirmed the same lifetime problem in Event Log replay; the EventLog cleanup in this fix addresses that case too.
Release status: this fix is on
mainfor the v2.2.2 release train. The publishedv2.2.2-rc.2executable predates the fix and remains affected; its tag and asset have not been replaced.