OpenHydronic — Home Assistant integration

Validate License: GPL v3 hacs_badge Home Assistant

Custom integration and Lovelace card for OpenHydronic, the open source ESP32 firmware that replaces the zone controller of an underfloor heating or radiator installation.

The firmware protects the hardware; this integration is the thermal brain on top of it. It binds each relay to any temperature sensor you already have, runs a thermostat per zone, manages the boiler or circulator, and watches the sensors for silence.

Note

The split between the two repositories is deliberate. Critical protections exist on both sides: if Home Assistant goes down the board keeps the installation safe on its own, and if the board goes down Home Assistant marks the zones unavailable and notifies you. Home Assistant is never the only guard.


What you get

  • Any relay, any sensor. A zone is one switchable entity plus one temperature sensor, so Zigbee, BLE, Wi-Fi or wired sensors all work, and the relay does not have to be an OpenHydronic board at all.
  • A thermostat per zone with configurable hysteresis (±0.3 °C by default) and Comfort, Eco and Away presets, exposed as standard climate entities.
  • mDNS discovery. Boards announce themselves as openhydronic-* and show up as a discovery card. Several boards in one instance are supported and coordinated together.
  • Flexible master manager, in three modes: disabled (100% actuators), a physical relay on a board, or any external Home Assistant entity such as switch.buffer_pump.
  • The firmware protections, mirrored. Thermal start delay, residual heat purge and minimum ON/OFF cycle guards run here as well, so an installation driving third-party relays is just as protected.
  • Bypass zone. Mark one zone as the bypass and it opens by itself whenever the circulator runs against a closed circuit.
  • Sensor watchdog. A sensor that stops updating for two hours switches its zone off and raises a persistent notification.
  • Routines run on the board. Air purge, anti-seize and emergency stop are handed to the firmware when the board exposes them, so a 30 minute purge survives a Home Assistant restart. Without an OpenHydronic board they run here instead.
  • Metrics per actuator: runtime hours and cycle counts, ready for the energy dashboard.
  • Bundled Lovelace card, registered automatically, no manual resource entry, no CDN, English and Portuguese.

Compatibility

Item Requirement
Home Assistant 2024.10 or newer
Board OpenHydronic firmware, or any switch-like entity
Sensors One temperature sensor per zone (sensor, number or input_number)
Relay domains switch, input_boolean, light, fan, valve
Installation HACS custom repository, or manual copy

Installation

1. Flash the board

Follow the OpenHydronic README. When it is done you should have an ESPHome device in Home Assistant with Zone 1 … Zone 8 switches.

The official ESPHome integration is the transport; this custom component is the decision layer on top of it.

2. Install the integration

Via HACS (recommended)

  1. HACS → Integrations → ⋮ → Custom repositories
  2. URL https://github.com/davdlic/OpenHydronic-HA, category Integration
  3. Install OpenHydronic and restart Home Assistant

Manual

Copy custom_components/openhydronic/ into <config>/custom_components/ and restart.

The Lovelace card is served and loaded by the integration itself from /openhydronic_frontend/openhydronic-card.js. Nothing to add under Settings → Dashboards → Resources.

3. Add the board

A board on the network shows up by itself under Settings → Devices & Services as a discovery. Otherwise use Add integration → OpenHydronic and type its IP.

4. Map the zones

Devices & Services → OpenHydronic → Configure:

Menu What it sets
Add zone Name, relay, temperature sensor, Comfort/Eco/Away setpoints, bypass flag
Master manager Disabled, physical relay, or external entity
Regulation and cycle timings Hysteresis, thermal delay, residual purge, min ON, min OFF
Protections and routines Sensor watchdog, air purge duration, anti-seize schedule

Every zone becomes a climate.<name> entity, with sensor.<name>_runtime and sensor.<name>_cycles alongside it.

5. Add the card

Edit the dashboard → Add card → search for OpenHydronic. With no configuration at all the card finds the zones by itself:

type: custom:openhydronic-card
title: Underfloor heating

Configuration

Everything is set in the UI. The defaults mirror the firmware:

Option Default Notes
Hysteresis 0.3 °C Zone calls below setpoint - h, releases above setpoint + h
Master start delay 180 s Time for the PTC heads to open before the pump starts
Residual heat purge 120 s Pump keeps running after the last zone closes
Minimum ON time 600 s Per relay
Minimum OFF time 600 s Per relay
Sensor watchdog 7200 s Stale sensor switches its zone off
Air purge duration 1800 s All valves open, pump running
Anti-seize Sunday 10:00, 300 s Weekly exercise of every actuator
Comfort / Eco / Away 21.0 / 18.5 / 16.0 °C Per zone

Entities

Entity Type Purpose
climate.<zone> climate Thermostat: setpoint, presets, HVAC action
sensor.<zone>_runtime sensor Actuator runtime, in hours
sensor.<zone>_cycles sensor Number of open cycles
sensor.<board>_master_state sensor disabled, off, waiting, on, purging
sensor.<board>_system_mode sensor normal, summer, holiday, air_purge, anti_seize
sensor.<board>_active_zones sensor Zones physically open
switch.<board>_summer_mode switch Heating off, anti-seize still runs
switch.<board>_holiday_mode switch Every zone clamps to its Away setpoint
switch.<board>_air_purge switch Manual air purge, auto-off on timeout

Each climate entity also publishes the attributes the card reads: valve_state, fault, locked_until, demand, runtime_hours, cycles, system_mode and master_state.


Lovelace card

type: custom:openhydronic-card
title: Underfloor heating
zones:                      # optional, empty = auto-detect
  - climate.living_room
  - climate.main_bedroom
  - climate.bypass
show_global: true           # Summer / Holiday / Air purge buttons
show_metrics: false         # runtime hours and cycles per zone

Valve states, matching what the coordinator decided:

Colour Meaning
Grey Closed
Pulsing orange Opening: PTC travel time, or waiting on the master thermal delay
Solid orange Open and flowing
Red Fault: the sensor watchdog tripped or the relay is unavailable

The card takes its language from Home Assistant, English or Portuguese.


Services and automations

Service Description
openhydronic.air_purge Opens every valve with the circulator running. Optional duration, default 1800 s.
openhydronic.stop_air_purge Cancels a running purge.
openhydronic.run_anti_seize Cycles every relay. Optional duration, default 300 s.
openhydronic.emergency_stop Closes everything now, ignoring the minimum cycle timers.
openhydronic.reset_metrics Clears runtime hours and cycle counters.

All of them take an optional entry_id; without it they apply to every board.

action: openhydronic.air_purge
data:
  duration: 1800

Turn the heating off while a window is open:

automation:
  - alias: Living room window open
    triggers:
      - trigger: state
        entity_id: binary_sensor.living_room_window
        to: "on"
        for: "00:02:00"
    actions:
      - action: climate.set_hvac_mode
        target:
          entity_id: climate.living_room
        data:
          hvac_mode: "off"

Stop everything when the water pressure drops:

automation:
  - alias: Low heating pressure
    triggers:
      - trigger: numeric_state
        entity_id: sensor.boiler_pressure
        below: 0.8
    actions:
      - action: openhydronic.emergency_stop

How the control loop works

sensors ──► hysteresis ──► cycle guards ──► zone relays
                 │
                 └──────► master state machine ──► bypass
  1. Hysteresis — a zone calls for heat below setpoint - 0.3 °C and releases above setpoint + 0.3 °C.
  2. Cycle guards — a relay that just turned on stays on for 10 minutes, one that just turned off stays off for 10 minutes. A sensor fault breaks the lock to turn a zone off, never to turn it on: safety always wins.
  3. Master — on the first request it waits 3 minutes, the time the PTC heads need to open, before starting the circulator. After the last one it keeps running for 2 minutes to dissipate residual heat.
  4. Bypass — if the circulator is running and no zone is open, the zone marked as bypass opens to give the pump somewhere to push.
  5. Watchdog — a sensor silent for more than 2 hours switches its zone off and notifies.

The loop re-derives every timer on each pass (15 s, plus state-change events), and the cycle timestamps are persisted, so restarting Home Assistant neither leaves the circuit in an undefined state nor locks the zones out.


Troubleshooting

Symptom Likely cause Fix
A zone never calls for heat The sensor is stale or unavailable Check the notification; the watchdog holds the zone off on purpose.
A zone will not turn on right away Minimum OFF lock Normal. locked_until on the climate entity counts it down.
The master never starts Master manager disabled, or no entity selected Options → Master manager.
The circulator runs with everything closed No bypass configured Mark a zone as the bypass loop, or fit a mechanical one.
The card does not appear Browser cache after an update Hard refresh, Ctrl+Shift+R.
The card shows no zones No zones mapped yet Options → Add zone.
The board was added twice Added manually and then discovered Remove one entry; newer versions merge them automatically.

Enable debug logging:

logger:
  logs:
    custom_components.openhydronic: debug

Known limitations

  • The integration mirrors the firmware protections but cannot enforce them on third-party relays beyond switching them: a relay driven by something else can still be toggled behind its back.
  • A custom air purge duration is pushed to the board's own Air Purge Duration number entity when it can be found. If it cannot, the board keeps its configured duration and only the Home Assistant side honours the custom value.
  • The anti-seize schedule runs on Home Assistant's clock. The board has its own weekly schedule as a backup, which needs a time source.
  • Zone metrics count what the relay actually did, so they reset if you rebuild a zone from scratch.

FAQ

Do I need the OpenHydronic firmware? No. Any switchable entity works as a zone relay. With the firmware you additionally get the hardware-side protections and routines that survive a Home Assistant outage.

Can I use it with radiators instead of underfloor heating? Yes. Shorten the master start delay if the valves are fast, and keep the minimum cycle guards.

Several boards? Add each one as its own entry. Zones from different boards can share a single master.

Does it need the internet? No. Everything is local, including the Lovelace card.


Contributing

Pull requests are welcome. Read CONTRIBUTING.md first, especially the rule that all decisions belong in coordinator.py.


Changelog

See CHANGELOG.md.


Acknowledgments

Built on ESPHome and the Home Assistant developer APIs. Thanks to everyone who documented the quirks of thermal actuators and boiler room-stat inputs so this did not have to be learned the expensive way.


License

GNU General Public License v3.0. See LICENSE.