goldshell-config (MaVeTh fork)

Fork of BitcoinMechanic/goldshell-config for Goldshell Blake2b control-plane notes.

Upstream proved the SC Lite can be reclocked via the stock web API.
This fork documents what we verified in the MaVeTh TN4 / BIP-110 lab on a live Goldshell SC Lite (fw 2.2.0): fans, tempcontrol, auth, ports, and safety.

Not firmware. Not a shell exploit. Stock HTTP + BFGMiner API only.

How-to: connect + control fans

Start here: sc-lite/CONNECT_AND_FANS.md

Run & test the Python tools / temp manager: sc-lite/python/README.md

Covers ports, JWT login (browser or auto AES), powerplan fan kicks, how long fans stay up in auto mode, the interactive temp manager, and an abort-safe tempcontrol off test.

These helpers only talk to the miner over LAN — they are not tied to a BIP-110 checkout. A local working copy (e.g. O:\HSlite) is fine; keep this repo as the canonical source.

Models (siblings — different hardware)

Layout follows upstream: one directory per product. SC Lite / HS Box / SC Pro are not the same equipment.

Path What
sc-lite/ SC Lite — verified tools + fan/temp docs (fw 2.2.0)
hs-box/ HS Box — fans + float-V / optional-PV dialect confirmed (live — Hersh-23); helpers in hs-box/python/
sc5-pro/ SC Pro / SC5 Pro — placeholder (known harder; no helpers yet)

Findings so far (SC Lite fw 2.2.0)

Open / closed ports

Port State What it is / how we use it
80 Open Stock Yotta MC web UI. Main control plane: /mcb/*, /user/login, /dbg/*.
4028 Open Classic BFGMiner / intminer JSON API (no JWT). Great for quick summary / pools / devs / config reads.
22 Closed No SSH
23 Closed No telnet
2222 Closed No alt-SSH
443 Closed No HTTPS UI on our unit

There is no network shell. Writes go through HTTP PUT /mcb/setting (JWT). The box persists under /usr/config/… itself.

What we’re using today

Tool / surface Role
GET /user/login?…&cipher=true Auto JWT (AES-CBC, key !!!!!!!!!!!!!!!!, zero IV, ZeroPadding → hex)
GET/PUT /mcb/setting Clock / fan-bias powerplan, manual, tempcontrol, ledcontrol
GET /mcb/status Model / firmware (Goldshell-SCLITE, 2.2.0)
GET /mcb/pools Stratum URL / worker
GET /mcb/cgminer?cgminercmd=devs Per-board temp, fan RPM string, hashrate
GET /dbg/minerinfo Voltage / clock / fans (JWT)
GET /dbg/icinfo Per-chip / CPB board map
GET /dbg/fanctrllog Proves target_temp:85 + duty step-up/down
GET /dbg/minerhistory Algo/plan/pool change log (internal encoding)
GET /dbg/psinfo Process list (intminer, minerd, fanctrl, local /bin/login)
TCP :4028 Unauthenticated miner API reads; write cmds exist but Access: N
Upstream bash (miner-profile etc.) Reclock profiles (browser JWT)
sc-lite/python/* Auto-login helpers, abort-safe tempcontrol test, temp manager (kick fans when hot)
sc-lite/POOL_FAILBACK.md / python/sclite_pool_failback.py Sticky failover → kick preferred pool (PUT /mcb/pools + soft restart)
sc-lite/webui/ Fleet web UI — multi-miner fans/pools/failback/auto-fan (copy miners.example.json → miners.json)

Lab known fact: ~3s Stratum flap is NORMAL

Goldshell intminer often opens/closes DATUM Stratum about every ~3 seconds in logs. That is expected — not a DATUM failure. Judge health by DATUM client row (Subbed + username), then DiffA / hashrate, not by the flap lines.

Behavior findings

  1. Powerplan string shape:
    <MHz> MHz <mV> V <fanA> RPM <fanB> RPM PV <pv>
    Example stock: 625 MHz 9100 V 40 RPM 40 RPM PV 9400
  2. Internal encoding (from /dbg/minerhistory):
    intchains_qomo:vfff=<pv>:<MHz>:<fanA>:<fanB>:<mV> + algo=blake2b(SC)
    Driver name: intchains_qomo.
  3. Fan “RPM” fields are not literal RPM. Live fans run ~1000–1800. Those fields are a shared duty bias / kick for all fans together. No per-fan API.
  4. Fans do not stay pinned high with tempcontrol=true. fanctrl walks duty back toward holding the hot board near ~85°C. Peak blast ~10–20s; clearly elevated ~1–3 minutes.
  5. tempcontrol boolean is API-exposed. The target_temp value (85) is not editable via /mcb/setting (only visible in fanctrllog).
  6. tempcontrol=false + fan kick cooled boards in a timed test (peak ~83.4°C over 90s) but live RPM still drifted some — not a perfect hard lock. Always restore tempcontrol=true with an abort watchdog.
  7. Enabling manual=true can briefly bump reported chip voltage (we saw 9000 ↔ 9330 mV) even when the plan still said 9100 V. Re-check /dbg/minerinfo after PUTs.
  8. Hot board (often board 0 / CPB0 in icinfo) is the limiter; cooler boards can look fine while board 0 sits on the 85°C target.
  9. Runtime process picture: intminer -c /usr/config/bfgminer/bfgminer.json, plus minerd / xminerd, fanctrl, busybox ntpd. Debug dumps shell out to /backup/minerd/trash/… from the web backend — still not a remote shell for us.
  10. :4028 devdetails reported Target ~89°C / Cutoff ~95°C (informational). Do not treat cutoff as your abort line — abort earlier (we used ≥88°C).
  11. Hash method on :4028 coin showed blake2b while pointed at our DATUM stratum.
  12. Live algo setting is single-algo: blake2b(SC) only. Tutorial JSON still lists HNS pool links (shared UI leftover) — not proof this unit can switch algos.

Extra API surface (mapped, mostly unused by us)

Endpoint Notes
/mcb/algosetting {"algos":[{"name":"blake2b(SC)","id":0}],"algo_select":0}
/mcb/newpool, /mcb/delpool, /mcb/resultpool Pool add/remove/reorder API present
/mcb/ip DHCP (useDHCP/useAuto true on our unit)
/mcb/wifisetting exist:false — no WiFi hardware path here
/mcb/cmossetting Present but enable:false / no userkey
/mcb/rgbsetting Empty on this unit
/mcb/ledcontrol via setting Boolean LED toggle
/cpb/hshistory Hashrate history array for UI charts
/user/updatepd Password change
/mcb/restart Soft restart — dangerous if poked casually
/mcb/facrst Factory reset — dangerous
/mcb/uploadimage Firmware/image upload path

:4028 write-ish commands (addpool, setconfig, save, restart, privileged, pgaset, …) exist but returned Access: N. Use :80 + JWT for control; :4028 for monitoring.

Still unknown / not done

  • Editing target_temp without firmware / on-box file access
  • Privileged :4028 writes (Access: N so far)
  • Per-fan / per-board independent fan PWM
  • SC5 Pro (upstream: more annoying/sensitive)
  • Whether PV / vfff experiments are safe
  • Braiins-style per-chip voltage tooling — not in this stock API

Lab context (why we care)

We’re running BIP-110 / Blake2b work against DATUM on TN4. The SC Lite is pointed at local DATUM stratum and used as a real ASIC under test. Tuning fans/clocks from the LAN (without cracking open the box) helps thermal noise and flap while we iterate pool/coinbase paths.

Layout

sc-lite/
  CONNECT_AND_FANS.md # start here: connect + fan control writeup
  README.md           # detailed API map, dbg, safety
  miner-health        # upstream bash (needs browser JWT)
  miner-profile       # upstream bash reclock profiles
  miner-runtime       # upstream bash voltage/clock dump
  sclite-miner.conf   # env template
  python/             # MaVeTh helpers (auto-login)
  POOL_FAILBACK.md    # sticky failover kick helper

License

MIT — see LICENSE (Copyright (c) 2025-2026 MaVeTh).

Adapted ProductGuy recoverability / multi-board bits remain MIT as well; see sc-lite/webui/ATTRIBUTION.md and keep those notices if you redistribute those files. Commercial / product-line forks are fine under MIT so long as the notices travel with the code.

Credit

Original SC Lite tooling and reclock discovery: BitcoinMechanic.
Lab verification / fan + tempcontrol notes / pure SC Lite CLI helpers (sc-lite/python) / fleet webui: MaVeTh.
ProductGuy (MIT): multi-board / soft-watchdog adaptations — see webui ATTRIBUTION.md.

If you learn more on SC5 Pro or other Blake2b Goldshells, PRs welcome upstream and here.

About

No description, website, or topics provided.

Resources

Stars

2 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages