Skip to content

fix(ex-gwf-maw-collector): give the caisson no connection - #365

Merged
jdhughes-dev merged 1 commit into
MODFLOW-ORG:developfrom
jdhughes-dev:ex-maw-collector-no-conn-status
Oct 28, 2026
Merged

jdhughes-dev merged 1 commit into
MODFLOW-ORG:developfrom
jdhughes-dev:ex-maw-collector-no-conn-status

Conversation

@jdhughes-dev

Copy link
Copy Markdown
Contributor

The unscreened caisson was an inactive first connection set with the MAW CONNECTION_STATUS setting, which MODFLOW-ORG/modflow6#3089 removes from 6.8.2. The caisson now has no connection, so the laterals are connections 1 to 48; the simulated heads are unchanged to within 3.2e-10 m. This needs to merge before MODFLOW-ORG/modflow6#3089, whose documentation build runs this example.

The unscreened caisson was an inactive first connection set with the MAW
CONNECTION_STATUS setting, which modflow6 removes from 6.8.2
(MODFLOW-ORG/modflow6#3089). The caisson now has no connection, so the
laterals are connections 1 to 48. An inactive connection exchanges no
water, so the simulated heads are unchanged to within 3.2e-10 m.
@jdhughes-dev
jdhughes-dev merged commit 0d0a8c0 into MODFLOW-ORG:develop Oct 28, 2026
7 checks passed
@jdhughes-dev
jdhughes-dev deleted the ex-maw-collector-no-conn-status branch October 28, 2026 14:45