Conformal prediction for motor-imagery brain-computer interfaces (BCIs): prediction sets with finite-sample coverage guarantees, abstention, and a bound on wrong feedback, for decoders used in stroke rehabilitation.
In motor-imagery neurofeedback for stroke rehabilitation, the decoder decides when
the patient is told "that attempt worked". The therapeutic premise is that feedback
contingent on the intended sensorimotor activity reinforces it, so feedback given
on a wrong decode is worse than no feedback. Standard decoders nevertheless return
a hard label on every trial, including when cross-subject accuracy on patients is
near chance. confbci wraps a decoder so that it returns a prediction set
({left}, {right}, or {left, right} = abstain). If calibration and test trials
are exchangeable, the true label is in the set with probability at least
1 - alpha, for any decoder and any data distribution. The toolkit also provides
the corrections needed when exchangeability fails across subjects and within a
session, and a benchmark that measures when it fails.
pip install -e .
pytest # 237 tests, synthetic data only, about a minuteAny scikit-learn-compatible classifier with predict_proba and classes_ works,
including any pyRiemann pipeline:
from sklearn.pipeline import make_pipeline
from sklearn.linear_model import LogisticRegression
from pyriemann.estimation import Covariances
from pyriemann.tangentspace import TangentSpace
from confbci import SplitCP
clf = make_pipeline(Covariances("oas"), TangentSpace(), LogisticRegression())
clf.fit(X_train, y_train) # epochs: (trials, channels, samples)
cp = SplitCP(clf, alpha=0.2).calibrate(X_cal, y_cal) # trials the decoder never saw
sets = cp.predict_set(X_new) # bool array (trials, classes)
give_feedback = sets.sum(axis=1) == 1 # commit only when one label remainscp.coverage(sets, y_new) returns the empirical coverage. The calibration trials
must not have been used to fit clf.
| Object | Purpose | Guarantee, and what it assumes |
|---|---|---|
ProbMDM |
Minimum distance to mean with probabilities softmax(-d_R^2 / tau); optional Riemannian re-centering per subject |
none (a decoder) |
LAC, RiemannianMargin |
Nonconformity scores: 1 - p(y) and d_R(C, M_y) - min_{k != y} d_R(C, M_k) |
none |
SplitCP |
Split conformal prediction | 1 - alpha <= P(Y in C(X)) <= 1 - alpha + 1/(n+1); exchangeable calibration and test trials |
WeightedCP + DomainClassifierDensityRatio |
Weighted conformal prediction for covariate shift | coverage >= 1 - alpha if the weights equal the true density ratio and P(y | x) is shared |
MondrianCP |
Per-subject threshold from a short labelled block | as SplitCP, within each subject |
AdaptiveCI |
Online update of the working level after each cue | long-run miscoverage within (max(alpha, 1-alpha) + gamma) / (gamma T) of alpha; no assumption on the data |
crc_feedback_threshold |
Confidence threshold for giving feedback | P(feedback given AND wrong) <= alpha; exchangeable trials |
screening_metrics |
Spearman rho and AUROC between block singleton rate and held-out accuracy | none (a statistic) |
LOSOConformalEvaluation holds out one subject at a time and evaluates three
regimes, which differ in what is known about the new patient.
R1, zero calibration. No labelled trial from the target. Source subjects are
split by subject into training subjects (fit the decoder) and calibration
subjects (fit the threshold). Methods: pooled (plain split CP), weighted
(density-ratio weights between calibration trials and the target's unlabeled
trials), recentered (every subject's Riemannian mean moved to the identity, the
target's from its own unlabeled trials, then split CP). Validity here rests on the
target being exchangeable with the calibration subjects after the correction.
R2, few-shot. The first k trials per class of the target, k in
{2, 4, 8, 16, 32}, form a labelled calibration block with a per-subject (Mondrian)
threshold; the remaining trials are the test set. Each configuration is run in
recorded order (chronological) and with a randomly drawn block (shuffled).
Shuffling makes calibration and test exchangeable by construction, so the gap
between the two orders measures within-session non-stationarity. With n = 2k
calibration trials the expected coverage is ceil((n+1)(1-alpha)) / (n+1), and
n >= 1/alpha - 1 is needed for a finite threshold.
R3, online. Trials are processed in recorded order; after each one the cue is
revealed and AdaptiveCI moves its working level
alpha_{t+1} = alpha_t + gamma (alpha - err_t). The predictor starts from the
calibration subjects' scores. Reported per session: rolling 20-trial coverage,
long-run coverage error, and the trajectory of alpha_t, for static (never
updated), aci, and aci_recentered.
from confbci import LOSOConformalEvaluation, RiemannianMargin, summarize
ev = LOSOConformalEvaluation(score=RiemannianMargin(), alpha=0.2)
records = ev.run_moabb("Liu2024", regimes=("R1", "R2", "R3"))
summary = summarize(records)python benchmarks/run_benchmark.py --dataset Liu2024 # writes results/*.csv
python benchmarks/make_figures.py --records results/Liu2024_records.csv
python benchmarks/make_figures.py --demo # synthetic subjects, no download- Coverage is marginal. It holds on average over trials, not for each trial or each class. At chance-level accuracy a valid predictor abstains on most trials; that is the correct output, not a failure.
- The online bound is a long-run average and is vacuous for short sessions. For
T = 40trials andgamma = 0.05it equals 0.43. It says nothing about any 20-trial window. - Risk control bounds a joint rate.
P(feedback AND wrong) <= alphais per trial attempted. The error rate among trials that receive feedback is larger by the factor1 / P(feedback). aci_recenteredandstatic_recenteredare not causal. They re-center a session with the mean of all its trials, including future ones, and are an offline upper bound (causal = Falsein the records).- Weighted CP needs overlapping domains. In the tangent space
(
c (c + 1) / 2dimensions) a domain classifier can separate two subjects perfectly. The weights then put nearly all mass at+inf(inf_mass_near 1) and the method returns the full label set: valid, and uninformative. - Re-centering and exchangeability. With
recenter=True, a subject's calibration and test trials must be re-centered with the same reference: score them in one call and use the*_from_scoresmethods. - The simulator draws a wrapped (log-normal) Gaussian on the SPD manifold, not the maximum-entropy Riemannian Gaussian.
A tool paper is in paper/confbci.tex. Until it has a DOI, cite the repository.
BSD-3-Clause.