HostTime: barPhase output incorrect for Bars/4 and Bars/8 divisions #919
When using the Bar Phase output from the Cardinal Host Time module with Bars/4 or Bars/8 selected, the voltage
does not sweep smoothly from 0 to 10V across the full bar division.
Instead, the phasor resets at different voltages each cycle. For example
with Bars/4 in 4/4 time:
Bar 1: 0 to ~2.5V
Bar 2: ~0.6 to ~3.1V
Bar 3: ~1.2 to ~3.7V
Bar 4: ~1.8 to ~4.3V
Bar 5: resets back to 0 to ~2.5V
The expected behavior shoul be a smooth 0 to 10V phasor across all 4 bars.
This is caused by the barPhase formula not normalizing beat position
into fractional bars before applying the modulo operation.