98 changes: 98 additions & 0 deletions data/input/equipment_data.JSON
Original file line number Diff line number Diff line change
Expand Up @@ -817,6 +817,31 @@
}
}
},
{
"eq_id": "bo05",
"eq_type": "backup_heating",
"eq_subtype": "hot_water",
"eq_calc_type": "specific",
"model": "GenericBoiler",
"fuel": "natural_gas",
"capacity_W": 190500,
"dimensions": {
"length": 1.06,
"width": 0.833,
"height": 2.01
},
"operating_weight_g": 305000,
"electrical": {
"mca": 10,
"voltage": 120,
"phase": 1
},
"performance": {
"heating": {
"efficiency": 0.6
}
}
},
{
"eq_id": "ch01",
"eq_type": "chiller",
Expand Down Expand Up @@ -1009,6 +1034,7 @@
"awhp_use_cooling": false,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1026,6 +1052,7 @@
"awhp_use_cooling": false,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1043,6 +1070,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1060,6 +1088,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1077,6 +1106,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1094,6 +1124,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1111,6 +1142,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1128,6 +1160,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1145,6 +1178,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1162,6 +1196,7 @@
"awhp_use_cooling": false,
"awhp_sizing_priority": "heating",
"backup_heating": "bo03",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1179,6 +1214,7 @@
"awhp_use_cooling": false,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1196,6 +1232,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1213,6 +1250,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1230,6 +1268,7 @@
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"fuel_switching": false,
"chiller": "ch02"
},
{
Expand All @@ -1248,6 +1287,60 @@
"awhp_sizing_priority": "heating",
"backup_heating": "res02",
"chiller": "ch02"
},
{
"eq_scen_id": "eq_scenario_16",
"eq_scen_name": "90% Eff. Gas Boiler+AC Chiller",
"hr_wwhp": null,
"hr_wwhp_performance_model": "interpolate_HHWST",
"hr_wwhp_h_supply_t": 48.9,
"awhp": null,
"awhp_performance_model": "interpolate_HHWST_fixed",
"awhp_sizing_mode": "integer_sizing_peak_load",
"awhp_sizing_value": 1,
"awhp_redundancy": 1,
"awhp_h_supply_t": 38,
"awhp_use_cooling": false,
"awhp_sizing_priority": "heating",
"backup_heating": "bo02",
"fuel_switching": false,
"chiller": "ch02"
},
{
"eq_scen_id": "eq_scenario_17",
"eq_scen_name": "50% AWHP (H+C)+Gas Backup",
"hr_wwhp": null,
"hr_wwhp_performance_model": "interpolate_HHWST",
"hr_wwhp_h_supply_t": 48.9,
"awhp": "hp01",
"awhp_performance_model": "interpolate_HHWST_fixed",
"awhp_sizing_mode": "integer_sizing_peak_load",
"awhp_sizing_value": 0.5,
"awhp_redundancy": 1,
"awhp_h_supply_t": 38,
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo02",
"fuel_switching": false,
"chiller": "ch02"
},
{
"eq_scen_id": "eq_scenario_18",
"eq_scen_name": "100% AWHP (H+C)+Fuel Switching",
"hr_wwhp": null,
"hr_wwhp_performance_model": "interpolate_HHWST",
"hr_wwhp_h_supply_t": 48.9,
"awhp": "hp01",
"awhp_performance_model": "interpolate_HHWST_fixed",
"awhp_sizing_mode": "integer_sizing_peak_load",
"awhp_sizing_value": 1,
"awhp_redundancy": 1,
"awhp_h_supply_t": 38,
"awhp_use_cooling": true,
"awhp_sizing_priority": "heating",
"backup_heating": "bo02",
"fuel_switching": true,
"chiller": "ch02"
}
],
"scenario_groups": [
Expand All @@ -1270,6 +1363,11 @@
"group_id": "hhw_supply_temps",
"group_name": "HHW Supply Temps",
"scenario_ids": ["eq_scenario_4", "eq_scenario_13", "eq_scenario_14", "eq_scenario_5", "eq_scenario_15"]
Comment thread
urwahah marked this conversation as resolved.
},
{
"group_id": "fuel_switching",
"group_name": "Dynamic Fuel Switching",
"scenario_ids": ["eq_scenario_16", "eq_scenario_17", "eq_scenario_4", "eq_scenario_18"]
}
]
}
10 changes: 8 additions & 2 deletions layout/input.py
Original file line number Diff line number Diff line change
Expand Up @@ -542,9 +542,10 @@ def build_equipment_table(
("awhp_sizing_mode", "AWHP Sizing Mode"),
("awhp_sizing_value", "AWHP Sizing Value"),
("awhp_redundancy", "AWHP Redundancy"),
("awhp_use_cooling", "AWHP Use Cooling"),
("awhp_use_cooling", "Use AWHP for Cooling"),
("awhp_sizing_priority", "AWHP Sizing Priority"),
("backup_heating", "Backup Heating"),
("fuel_switching", "Use Optimal Heating Fuel"),
("chiller", "Backup Cooling"),
]

Expand Down Expand Up @@ -998,7 +999,7 @@ def edit_equipment_modal():
[
dmc.Switch(
id="edit-awhp-use-cooling",
label="Use heat pump also for cooling",
label="Use AWHP for cooling",
mt="xs",
),
dmc.Select(
Expand Down Expand Up @@ -1050,6 +1051,11 @@ def edit_equipment_modal():
),
],
),
dmc.Switch(
id="edit-fuel-switching",
label="Use optimal heating fuel",
mt="xs",
),
dmc.Text(
id="edit-scenario-error",
size="xs",
Expand Down
3 changes: 2 additions & 1 deletion layout/output.py
Original file line number Diff line number Diff line change
Expand Up @@ -174,9 +174,10 @@ def get_value(self, path: str):
("awhp_sizing_mode", "AWHP Sizing Mode"),
("awhp_sizing_value", "AWHP Sizing Value"),
("awhp_redundancy", "AWHP Redundancy"),
("awhp_use_cooling", "AWHP Use Cooling"),
("awhp_use_cooling", "Use AWHP for Cooling"),
("awhp_sizing_priority", "AWHP Sizing Priority"),
("backup_heating", "Backup Heating"),
("fuel_switching", "Use Optimal Heating Fuel"),
("chiller", "Chiller"),
]

Expand Down
40 changes: 38 additions & 2 deletions pages/equipment_page.py
Original file line number Diff line number Diff line change
Expand Up @@ -684,6 +684,7 @@ def reset_equipment(n_clicks, initial_data):
Output("edit-awhp-sizing-priority", "value"),
Output("edit-backup-heating-select", "data"),
Output("edit-backup-heating-select", "value"),
Output("edit-fuel-switching", "checked"),
Output("edit-chiller-select", "data"),
Output("edit-chiller-select", "value"),
Output("edit-scenario-error", "children"),
Expand All @@ -698,7 +699,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
pre-filling all editable fields.
"""
if not any(edit_clicks or []):
return (no_update,) * 21
return (no_update,) * 22

if not equipment_data:
return (
Expand All @@ -720,6 +721,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
None,
[],
None,
False,
[],
None,
"No equipment data.",
Expand All @@ -730,7 +732,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):

triggered = callback_context.triggered
if not triggered:
return (no_update,) * 21
return (no_update,) * 22

prop_id = triggered[0]["prop_id"]
id_str = prop_id.split(".")[0]
Expand All @@ -757,6 +759,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
None,
[],
None,
False,
[],
None,
"Failed to parse button id.",
Expand Down Expand Up @@ -787,6 +790,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
None,
[],
None,
False,
[],
None,
f"Scenario {eq_scen_id!r} not found.",
Expand Down Expand Up @@ -849,6 +853,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
redundancy = scenario.get("awhp_redundancy", 1)
use_cooling = scenario.get("awhp_use_cooling", False)
sizing_priority = scenario.get("awhp_sizing_priority") or "heating"
fuel_switching = scenario.get("fuel_switching", False)

backup_heating_val = scenario.get("backup_heating")
chiller_val = scenario.get("chiller")
Expand All @@ -872,6 +877,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
sizing_priority,
backup_heating_options,
backup_heating_val,
fuel_switching,
chiller_options,
chiller_val,
"",
Expand All @@ -897,6 +903,7 @@ def open_edit_modal(edit_clicks, equipment_data, unit_mode):
State("edit-awhp-use-cooling", "checked"),
State("edit-awhp-sizing-priority", "value"),
State("edit-backup-heating-select", "value"),
State("edit-fuel-switching", "checked"),
State("edit-chiller-select", "value"),
State("equipment-store", "data"),
State("unit-toggle", "value"),
Expand All @@ -918,6 +925,7 @@ def save_edit_scenario(
use_cooling,
sizing_priority,
backup_heating_val,
fuel_switching,
chiller_val,
equipment_data,
unit_mode,
Expand Down Expand Up @@ -969,6 +977,7 @@ def save_edit_scenario(
redundancy = 1

use_cooling = bool(use_cooling)
fuel_switching = bool(fuel_switching)

scenarios = equipment_data["equipment_scenarios"]
updated = False
Expand All @@ -990,6 +999,7 @@ def save_edit_scenario(
new_scen["awhp_use_cooling"] = use_cooling
new_scen["awhp_sizing_priority"] = sizing_priority
new_scen["backup_heating"] = backup_heating_val
new_scen["fuel_switching"] = fuel_switching
new_scen["chiller"] = chiller_val
new_scenarios.append(new_scen)
updated = True
Expand Down Expand Up @@ -1177,6 +1187,32 @@ def update_sizing_priority(use_cooling, sizing_mode):
return disabled


@callback(
Output("edit-fuel-switching", "disabled"),
Output("edit-fuel-switching", "checked", allow_duplicate=True),
Input("edit-awhp-select", "value"),
Input("edit-backup-heating-select", "value"),
State("edit-fuel-switching", "checked"),
State("equipment-store", "data"),
prevent_initial_call=True,
)
def update_fuel_switching(awhp_id, backup_heating_id, fuel_switching, equipment_data):
"""Enable/disable fuel switching input and update value when AWHP or backup heating selection changes."""
# get backup heating fuel
equipment_list = equipment_data.get("equipment", []) if equipment_data else []
backup_heating = next((e for e in equipment_list if e.get("eq_id") == backup_heating_id), None)
backup_heating_fuel = backup_heating.get("fuel", "") if backup_heating else ""

# Disable input if AWHP is not selected, or if backup heating option is electric
awhp_selected = awhp_id and awhp_id != "None"
disabled = (not awhp_selected) or (backup_heating_fuel != "natural_gas")

# Set value to unchecked if disabled condition is met, otherwise preserve last value
checked = False if disabled else fuel_switching

return (disabled, checked)


# helper to build equipment options for Selects


Expand Down
Loading