diff --git a/changelog.d/+strahlenschutz-ueberwachung.added.md b/changelog.d/+strahlenschutz-ueberwachung.added.md
new file mode 100644
index 000000000..d03836d52
--- /dev/null
+++ b/changelog.d/+strahlenschutz-ueberwachung.added.md
@@ -0,0 +1 @@
+A Trupp-Typ marked "Strahlenschutz" in the Stammdaten records the OSL-Dosimeter, Alarmdosimeter, Maske and PA numbers of every Einsatzkraft before IM EINSATZ and the Alarmdosimeter Ablesewert in mSv or µSv, which may follow late from the Dekon-Platz but must be entered, or the dosimeter confirmed as nicht vorhanden, before the Einsatz can be closed (#994).
diff --git a/changelog.d/+trupp-named-by-number.added.md b/changelog.d/+trupp-named-by-number.added.md
new file mode 100644
index 000000000..97e49f9d9
--- /dev/null
+++ b/changelog.d/+trupp-named-by-number.added.md
@@ -0,0 +1 @@
+A Trupp-Typ can be set to "Funkrufname aus Nummer" in the Stammdaten, so the Atemschutz form asks for a number instead of a Funkrufname and the Trupp is called "CSA-Trupp 1" rather than "1 · CSA-Trupp" (#995).
diff --git a/docs/master-data.example.json b/docs/master-data.example.json
index 69c96c8fe..99c8ffbf1 100644
--- a/docs/master-data.example.json
+++ b/docs/master-data.example.json
@@ -35,8 +35,8 @@
{ "name": "Angriffstrupp", "memberCount": 2, "maxDurationMinutes": 30 },
{ "name": "Wassertrupp", "memberCount": 2, "maxDurationMinutes": 30 },
{ "name": "Schlauchtrupp", "memberCount": 2, "maxDurationMinutes": 30 },
- { "name": "CSA-Trupp", "memberCount": 3, "maxDurationMinutes": 20 },
- { "name": "Strahlenschutztrupp", "memberCount": 3, "maxDurationMinutes": 30 },
+ { "name": "CSA-Trupp", "memberCount": 3, "maxDurationMinutes": 20, "namedByNumber": true },
+ { "name": "Strahlenschutztrupp", "memberCount": 3, "maxDurationMinutes": 30, "radiationMonitoring": true },
{ "name": "LPA-Trupp", "memberCount": 2, "maxDurationMinutes": 60 }
],
"checklists": [
diff --git a/docs/master-data.md b/docs/master-data.md
index f0d8caf48..c157491d2 100644
--- a/docs/master-data.md
+++ b/docs/master-data.md
@@ -17,6 +17,23 @@ A Trupp is never fewer than two people and never more than three: the
Atemschutzüberwachung has exactly three positions (Truppführer, Truppmann,
2. Truppmann) and nowhere to write a fourth name.
+Two switches on the row change how a Trupp of that type is handled, again by the
+row and never by its name:
+
+- **Nummer** (`namedByNumber`): the Trupp is called by a number rather than a
+ vehicle's Funkrufname. The form asks for the number and names the Trupp
+ "CSA-Trupp 1" (#995).
+- **Strahlenschutz** (`radiationMonitoring`): the Trupp is under
+ Strahlenschutzüberwachung (#994). Every Einsatzkraft gets OSL-Dosimeter,
+ Alarmdosimeter, Maske and PA numbers, and the Trupp cannot go under
+ Atemschutz before both dosimeters are numbered or confirmed as nicht
+ vorhanden. The Alarmdosimeter's Ablesewert may come in late from the
+ Dekon-Platz, but the Einsatz cannot be closed before it is entered or the
+ dosimeter is confirmed as nicht vorhanden.
+
+A Trupp copies both switches when it is registered, so a row edited later does
+not change a Trupp already in an Einsatz.
+
There is no separate list of brigades (Wachen) or radio call signs
(Funkrufnamen): both are derived from the **vehicles** — every vehicle's Wache
becomes a brigade suggestion, and every vehicle's call sign (plus every roster
diff --git a/docs/samples/uebung.lagebuch b/docs/samples/uebung.lagebuch
index 3ee60a5ab..43417d199 100644
Binary files a/docs/samples/uebung.lagebuch and b/docs/samples/uebung.lagebuch differ
diff --git a/src/LageBuch.App.Shared/Views/IncidentWorkspaceView.axaml b/src/LageBuch.App.Shared/Views/IncidentWorkspaceView.axaml
index 27eefc903..a3d7276f8 100644
--- a/src/LageBuch.App.Shared/Views/IncidentWorkspaceView.axaml
+++ b/src/LageBuch.App.Shared/Views/IncidentWorkspaceView.axaml
@@ -1104,5 +1104,9 @@
+
+
+
diff --git a/src/LageBuch.App.Shared/Views/MasterDataEditorView.axaml b/src/LageBuch.App.Shared/Views/MasterDataEditorView.axaml
index e62e06047..8fbd8d0cd 100644
--- a/src/LageBuch.App.Shared/Views/MasterDataEditorView.axaml
+++ b/src/LageBuch.App.Shared/Views/MasterDataEditorView.axaml
@@ -1400,18 +1400,22 @@
HorizontalAlignment="Left" Margin="0,12,0,0" Command="{Binding AddCommand}" />
-
+
+
+
-
+
+
+
+
-
diff --git a/src/LageBuch.AppLogic/LocalIncidentSession.cs b/src/LageBuch.AppLogic/LocalIncidentSession.cs
index 88fa8d14b..ce482ec66 100644
--- a/src/LageBuch.AppLogic/LocalIncidentSession.cs
+++ b/src/LageBuch.AppLogic/LocalIncidentSession.cs
@@ -317,7 +317,8 @@ public void AddScbaTrupp(
string? task = null,
int maxDurationMinutes = AtemschutzTrupp.DefaultMaxDurationMinutes,
int returnPressureBar = AtemschutzTrupp.DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes) =>
+ int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false) =>
Mutate(() => Incident.AddScbaTrupp(
_clock,
designation,
@@ -328,7 +329,8 @@ public void AddScbaTrupp(
task,
maxDurationMinutes,
returnPressureBar,
- pressureControlIntervalMinutes));
+ pressureControlIntervalMinutes,
+ radiationMonitoring));
public void StartScbaTrupp(Guid truppId) =>
Mutate(() => Incident.StartScbaTrupp(_clock, truppId));
@@ -348,6 +350,9 @@ public void SetScbaSafetyTrupp(Guid truppId, Guid? safetyTruppId) =>
public void ChangeScbaTruppType(Guid truppId, string designation, int maxDurationMinutes, int pressureControlIntervalMinutes) =>
Mutate(() => Incident.ChangeScbaTruppType(truppId, designation, maxDurationMinutes, pressureControlIntervalMinutes));
+ public void RecordScbaRadiation(Guid truppId, TruppRole role, RadiationRecord record) =>
+ Mutate(() => Incident.RecordScbaRadiation(truppId, role, record));
+
public void SetIncidentNumber(IncidentNumber? number) => Mutate(() => Incident.SetIncidentNumber(number));
public void SetKeyword(string? keyword) => Mutate(() => Incident.SetKeyword(keyword));
diff --git a/src/LageBuch.AppLogic/ViewModels/IncidentWorkspaceViewModel.cs b/src/LageBuch.AppLogic/ViewModels/IncidentWorkspaceViewModel.cs
index 0451b986d..ef2dc5675 100644
--- a/src/LageBuch.AppLogic/ViewModels/IncidentWorkspaceViewModel.cs
+++ b/src/LageBuch.AppLogic/ViewModels/IncidentWorkspaceViewModel.cs
@@ -333,6 +333,10 @@ private void MarkSynced()
[ObservableProperty]
private RoleAssignmentDialogViewModel? _pendingRoleAssignmentDialog;
+ /// The Strahlenschutz dialog of a Strahlenschutztrupp (#994), opened from its row.
+ [ObservableProperty]
+ private RadiationDialogViewModel? _pendingRadiationDialog;
+
// ===== Header: display projections of the incident's head data. None of these write back --
// the only write path is the Einsatzdaten dialog (EditIncidentData), which replaced the inline
// Einsatznummer editor of #69. They are seeded in the constructor and refreshed from the
@@ -446,6 +450,12 @@ private void OpenRoleAssignmentDialog(RoleAssignmentDialogViewModel dialog)
PendingRoleAssignmentDialog = dialog;
}
+ private void OpenRadiationDialog(RadiationDialogViewModel dialog)
+ {
+ dialog.Closed += (_, _) => PendingRadiationDialog = null;
+ PendingRadiationDialog = dialog;
+ }
+
private void RefreshIncidentData()
{
var incident = _session.Incident;
@@ -781,7 +791,8 @@ PendingPrompt is not null || PendingConfirm is not null || PendingTaskDialog is
|| PendingSpellingHelper is not null
|| PendingCommandNodeDialog is not null || PendingDispatchChannelDialog is not null
|| PendingLeadershipPersonDialog is not null
- || PendingRoleAssignmentDialog is not null;
+ || PendingRoleAssignmentDialog is not null
+ || PendingRadiationDialog is not null;
private bool StepRail(int step)
{
@@ -1146,7 +1157,7 @@ private void BuildChildren()
IssuedItems = new IssuedItemsViewModel(
_session, OnChanged, _masterData.Devices, RequestConfirm, ContactEntry.Roster(_masterData.Personnel, _masterData.Vehicles));
- Scba = new ScbaViewModel(_session, _masterData, _clock, _ticker, _alarm, OnChanged);
+ Scba = new ScbaViewModel(_session, _masterData, _clock, _ticker, _alarm, OnChanged, OpenRadiationDialog);
Scba.RevealRequested += OnScbaRevealRequested;
Scba.PropertyChanged += OnHeaderSourceChanged;
@@ -1741,6 +1752,21 @@ private void OfferReminderReset()
[RelayCommand(CanExecute = nameof(CanClose))]
private void CloseIncident()
{
+ // #994: refused, not merely warned about -- a closed Einsatz is read-only, so an Ablesewert
+ // still missing now could never be added. The way out leads to where it is entered.
+ if (_session.Incident.ScbaTruppsAwaitingDoseReading is { Count: > 0 } awaiting)
+ {
+ var missing = string.Join(", ", awaiting.Select(t => t.DisplayName));
+ var refusal = new ConfirmDialogViewModel(
+ "Einsatz noch nicht abschließbar",
+ $"Ablesewerte fehlen: {missing}. Erst die Alarmdosimeter ablesen lassen und eintragen oder als nicht vorhanden bestätigen.",
+ "ZUR ATEMSCHUTZÜBERWACHUNG",
+ () => ShowModule(Scba));
+ refusal.Closed += (_, _) => PendingConfirm = null;
+ PendingConfirm = refusal;
+ return;
+ }
+
var activeTrupps = _session.Incident.ScbaTrupps.Count(t => t.IsActive || t.IsWithdrawing);
var itemsOut = _session.Incident.ItemsOut;
var warnings = string.Concat(
diff --git a/src/LageBuch.AppLogic/ViewModels/RadiationDialogViewModel.cs b/src/LageBuch.AppLogic/ViewModels/RadiationDialogViewModel.cs
new file mode 100644
index 000000000..a674a12d1
--- /dev/null
+++ b/src/LageBuch.AppLogic/ViewModels/RadiationDialogViewModel.cs
@@ -0,0 +1,171 @@
+using CommunityToolkit.Mvvm.ComponentModel;
+using CommunityToolkit.Mvvm.Input;
+using LageBuch.Domain.Atemschutz;
+using LageBuch.Domain.Etb;
+using LageBuch.Sync;
+
+namespace LageBuch.AppLogic.ViewModels;
+
+///
+/// The Strahlenschutzüberwachung of one Strahlenschutztrupp (#994), opened from its row: per crew
+/// member the numbers of OSL-Dosimeter, Alarmdosimeter, Maske and PA, and the Alarmdosimeter's
+/// Ablesewert once the Dekon-Platz reports it. Buffered until SPEICHERN; fires
+/// on every outcome so the host clears the overlay.
+///
+/// A dosimeter that is not there is declared, never left blank: "nicht vorhanden" asks first,
+/// because it breaks the chain of documentation, and the ETB and the Bericht say so.
+///
+///
+public sealed partial class RadiationDialogViewModel : ObservableObject
+{
+ private readonly IIncidentSession _session;
+ private readonly Guid _truppId;
+ private readonly Action? _onChanged;
+
+ // The declaration waiting for its confirmation, while the warning is up.
+ private (RadiationMemberRow Row, DosimeterKind Kind)? _pendingMissing;
+
+ /// The Einsatz holding the Trupp; its current records seed the rows.
+ /// A Trupp under Strahlenschutzüberwachung.
+ /// Called after a save that went through, so the host can persist.
+ public RadiationDialogViewModel(IIncidentSession session, Guid truppId, Action? onChanged = null)
+ {
+ ArgumentNullException.ThrowIfNull(session);
+ _session = session;
+ _truppId = truppId;
+ _onChanged = onChanged;
+ var trupp = session.Incident.ScbaTrupps.First(t => t.Id == truppId);
+ Title = $"Strahlenschutz · {trupp.DisplayName}";
+ Members = trupp.Members.Select(m => new RadiationMemberRow(m, RequestMissing)).ToList();
+ }
+
+ public event EventHandler? Closed;
+
+ /// "Strahlenschutz · HLF 1 · Strahlenschutztrupp".
+ public string Title { get; }
+
+ /// One row per crew member, in position order.
+ public IReadOnlyList Members { get; }
+
+ /// Why the last save was refused, in German; null otherwise.
+ [ObservableProperty]
+ private string? _saveError;
+
+ /// The warning shown before a dosimeter is declared missing; null while none is pending.
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(IsMissingPending))]
+ private string? _missingWarning;
+
+ public bool IsMissingPending => MissingWarning is not null;
+
+ private bool CanSave => !_session.IsReadOnly;
+
+ private void RequestMissing(RadiationMemberRow row, DosimeterKind kind)
+ {
+ _pendingMissing = (row, kind);
+ MissingWarning =
+ $"{DosimeterName(kind)} von {row.Name} nicht vorhanden? Damit ist die Dokumentationskette unterbrochen. "
+ + "Das wird im ETB und im Bericht vermerkt.";
+ }
+
+ /// NICHT VORHANDEN, confirmed: the row takes the declaration.
+ [RelayCommand]
+ private void ConfirmMissing()
+ {
+ if (_pendingMissing is { } pending)
+ {
+ pending.Row.SetMissing(pending.Kind, true);
+ }
+
+ _pendingMissing = null;
+ MissingWarning = null;
+ }
+
+ [RelayCommand]
+ private void CancelMissing()
+ {
+ _pendingMissing = null;
+ MissingWarning = null;
+ }
+
+ [RelayCommand(CanExecute = nameof(CanSave))]
+ private void Save()
+ {
+ SaveError = null;
+ if (!Members.All(m => m.Validate()))
+ {
+ return;
+ }
+
+ // A Trupp is never taken out of an Einsatz, so the one this dialog was opened for is there.
+ var trupp = _session.Incident.ScbaTrupps.First(t => t.Id == _truppId);
+ try
+ {
+ var changes = Members
+ .Select(row => (Row: row, Before: trupp.Members.First(m => m.Role == row.Role).Radiation ?? RadiationRecord.Empty, After: row.ToRecord()))
+ .Where(change => change.After != change.Before)
+ .ToList();
+ if (changes.Count == 0)
+ {
+ Closed?.Invoke(this, EventArgs.Empty);
+ return;
+ }
+
+ foreach (var (row, before, after) in changes)
+ {
+ _session.RecordScbaRadiation(_truppId, row.Role, after);
+ foreach (var line in JournalLines(trupp.DisplayName, row.Name, before, after))
+ {
+ _session.AddJournalEntry(EtbDirection.System, line, from: trupp.CallSign, to: null);
+ }
+ }
+ }
+ catch (Exception ex) when (ex is InvalidOperationException or ArgumentException)
+ {
+ SaveError = DomainRefusal.Message(ex);
+ return;
+ }
+
+ _onChanged?.Invoke();
+ Closed?.Invoke(this, EventArgs.Empty);
+ }
+
+ [RelayCommand]
+ private void Cancel() => Closed?.Invoke(this, EventArgs.Empty);
+
+ ///
+ /// The ETB lines one crew member's change writes: the numbers when they changed, a declared
+ /// missing dosimeter as its own ACHTUNG line, and the Ablesewert once it is there. These are
+ /// persisted and read back off the Einsatzbericht, so the wording is a data format.
+ ///
+ public static IEnumerable JournalLines(string trupp, string name, RadiationRecord before, RadiationRecord after)
+ {
+ ArgumentNullException.ThrowIfNull(before);
+ ArgumentNullException.ThrowIfNull(after);
+ if (before.OslDosimeterNumber != after.OslDosimeterNumber
+ || before.AlarmDosimeterNumber != after.AlarmDosimeterNumber
+ || before.MaskNumber != after.MaskNumber
+ || before.PaNumber != after.PaNumber)
+ {
+ yield return $"{trupp}: Strahlenschutz {name} – {after.NumbersDisplay}";
+ }
+
+ if (after.OslDosimeterMissing && !before.OslDosimeterMissing)
+ {
+ yield return $"ACHTUNG {trupp}: OSL-Dosimeter von {name} nicht vorhanden – Dokumentationskette unterbrochen";
+ }
+
+ if (after.AlarmDosimeterMissing && !before.AlarmDosimeterMissing)
+ {
+ yield return $"ACHTUNG {trupp}: Alarmdosimeter von {name} nicht vorhanden – Dokumentationskette unterbrochen";
+ }
+
+ if (after.AlarmReading is { } reading && reading != before.AlarmReading)
+ {
+ yield return $"{trupp}: Ablesewert Alarmdosimeter {name}: {reading.Display}";
+ }
+ }
+
+ private static string DosimeterName(DosimeterKind kind) =>
+ kind == DosimeterKind.Osl ? "OSL-Dosimeter" : "Alarmdosimeter";
+}
diff --git a/src/LageBuch.AppLogic/ViewModels/RadiationMemberRow.cs b/src/LageBuch.AppLogic/ViewModels/RadiationMemberRow.cs
new file mode 100644
index 000000000..17581bbba
--- /dev/null
+++ b/src/LageBuch.AppLogic/ViewModels/RadiationMemberRow.cs
@@ -0,0 +1,177 @@
+using System.Globalization;
+using CommunityToolkit.Mvvm.ComponentModel;
+using CommunityToolkit.Mvvm.Input;
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+
+namespace LageBuch.AppLogic.ViewModels;
+
+/// Which of a crew member's two dosimeters a declaration is about (#994).
+public enum DosimeterKind
+{
+ Osl,
+ Alarm,
+}
+
+///
+/// One crew member in the Strahlenschutz dialog (#994): the four numbers, the two "nicht
+/// vorhanden" declarations and the Ablesewert as typed. Declaring a dosimeter missing goes through
+/// the dialog, which asks first; taking it back does not need to.
+///
+public sealed partial class RadiationMemberRow : ObservableObject
+{
+ private readonly Action _requestMissing;
+
+ public RadiationMemberRow(TruppMember member, Action requestMissing)
+ {
+ ArgumentNullException.ThrowIfNull(member);
+ _requestMissing = requestMissing;
+ Role = member.Role;
+ Name = member.Name;
+ RoleDisplay = member.RoleDisplay;
+ var record = member.Radiation ?? RadiationRecord.Empty;
+ _oslNumber = record.OslDosimeterNumber;
+ _alarmNumber = record.AlarmDosimeterNumber;
+ _maskNumber = record.MaskNumber;
+ _paNumber = record.PaNumber;
+ _oslMissing = record.OslDosimeterMissing;
+ _alarmMissing = record.AlarmDosimeterMissing;
+ _doseText = record.AlarmReading?.Value.ToString("0.###", Formatting.NumberFormat);
+
+ // mSv unless the record says otherwise: the larger unit is what an Einsatz reports.
+ _doseUnit = record.AlarmReading?.Unit ?? DoseUnit.MilliSievert;
+ }
+
+ /// The longest number the boxes take, for the view.
+ public static int MaxNumberLength => RadiationRecord.MaxNumberLength;
+
+ /// The units the picker offers, mSv first.
+ public static IReadOnlyList UnitOptions { get; } =
+ [DoseReading.UnitLabel(DoseUnit.MilliSievert), DoseReading.UnitLabel(DoseUnit.MicroSievert)];
+
+ public TruppRole Role { get; }
+
+ public string Name { get; }
+
+ public string RoleDisplay { get; }
+
+ [ObservableProperty]
+ private string? _oslNumber;
+
+ [ObservableProperty]
+ private string? _alarmNumber;
+
+ [ObservableProperty]
+ private string? _maskNumber;
+
+ [ObservableProperty]
+ private string? _paNumber;
+
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(OslPresent))]
+ private bool _oslMissing;
+
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(AlarmPresent))]
+ private bool _alarmMissing;
+
+ /// The Ablesewert as typed, "0,12" or "0.12"; blank while it is not reported yet.
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(DoseError))]
+ private string? _doseText;
+
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(DoseUnitLabel))]
+ private DoseUnit _doseUnit;
+
+ /// The picker's side of : "mSv" or "µSv".
+ public string? DoseUnitLabel
+ {
+ get => DoseReading.UnitLabel(DoseUnit);
+ set
+ {
+ if (value is not null)
+ {
+ DoseUnit = string.Equals(value, DoseReading.UnitLabel(DoseUnit.MicroSievert), StringComparison.Ordinal)
+ ? DoseUnit.MicroSievert
+ : DoseUnit.MilliSievert;
+ }
+ }
+ }
+
+ /// Why the typed Ablesewert cannot be taken, once SPEICHERN was pressed; null otherwise.
+ [ObservableProperty]
+ private string? _doseError;
+
+ public bool OslPresent => !OslMissing;
+
+ public bool AlarmPresent => !AlarmMissing;
+
+ [RelayCommand]
+ private void DeclareOslMissing() => _requestMissing(this, DosimeterKind.Osl);
+
+ [RelayCommand]
+ private void DeclareAlarmMissing() => _requestMissing(this, DosimeterKind.Alarm);
+
+ [RelayCommand]
+ private void UndoOslMissing() => OslMissing = false;
+
+ [RelayCommand]
+ private void UndoAlarmMissing() => AlarmMissing = false;
+
+ /// Takes a confirmed declaration; a missing Alarmdosimeter has no Ablesewert.
+ public void SetMissing(DosimeterKind kind, bool missing)
+ {
+ if (kind == DosimeterKind.Osl)
+ {
+ OslMissing = missing;
+ return;
+ }
+
+ AlarmMissing = missing;
+ if (missing)
+ {
+ DoseText = null;
+ }
+ }
+
+ /// Checks the typed Ablesewert and says why it cannot be taken.
+ public bool Validate()
+ {
+ DoseError = AlarmMissing || string.IsNullOrWhiteSpace(DoseText) || TryParseDose(DoseText, out _)
+ ? null
+ : "Ablesewert als Zahl eingeben, z. B. 0,12";
+ return DoseError is null;
+ }
+
+ /// The record these fields describe. Call first.
+ public RadiationRecord ToRecord() => new(
+ OslNumber,
+ OslMissing,
+ AlarmNumber,
+ AlarmMissing,
+ MaskNumber,
+ PaNumber,
+ !AlarmMissing && TryParseDose(DoseText, out var value) ? new DoseReading(value, DoseUnit) : null);
+
+ ///
+ /// A typed Ablesewert, with "," or "." as the decimal separator and no grouping: a display
+ /// shows "0.12", the form shows "0,12", and both mean the same. Out of range is not a number
+ /// either, so the field says what it wants rather than the save failing on it.
+ ///
+ public static bool TryParseDose(string? text, out decimal value)
+ {
+ value = 0;
+ if (string.IsNullOrWhiteSpace(text))
+ {
+ return false;
+ }
+
+ return decimal.TryParse(
+ text.Trim().Replace(',', '.'),
+ NumberStyles.AllowDecimalPoint,
+ CultureInfo.InvariantCulture,
+ out value)
+ && value <= DoseReading.MaxValue;
+ }
+}
diff --git a/src/LageBuch.AppLogic/ViewModels/ScbaViewModel.cs b/src/LageBuch.AppLogic/ViewModels/ScbaViewModel.cs
index 5facbbb90..4ad3272b0 100644
--- a/src/LageBuch.AppLogic/ViewModels/ScbaViewModel.cs
+++ b/src/LageBuch.AppLogic/ViewModels/ScbaViewModel.cs
@@ -31,6 +31,7 @@ public sealed partial class ScbaTruppRow : ObservableObject
private readonly Action _onWithdraw;
private readonly Action _onMarkRemoved;
private readonly Action _onAssignSafetyTrupp;
+ private readonly Action? _onOpenRadiation;
// Re-pointed by Update rather than replaced with a whole new row (#294) -- see Update's remarks.
private AtemschutzTrupp _trupp;
@@ -51,10 +52,12 @@ public ScbaTruppRow(
string? safetyTruppHint,
string? coveredTrupps,
IReadOnlyList truppTypeChoices,
- Action onAssignSafetyTrupp)
+ Action onAssignSafetyTrupp,
+ Action? onOpenRadiation = null)
{
ArgumentNullException.ThrowIfNull(trupp);
_trupp = trupp;
+ _onOpenRadiation = onOpenRadiation;
_clock = clock;
_isReadOnly = isReadOnly;
_onStart = onStart;
@@ -228,7 +231,26 @@ partial void OnPressureInputChanged(int? value)
// Only the error: a warning is about the Druck, and still stands whatever the Ort says.
partial void OnLocationInputChanged(string? value) => PressureError = null;
- private bool CanStart => !_isReadOnly && _trupp.IsWaiting;
+ // A Strahlenschutztrupp waits for its dosimeter numbers (#994); the row's hint says so.
+ private bool CanStart => !_isReadOnly && _trupp.IsWaiting && !_trupp.LacksDosimeterNumbers;
+
+ /// Whether this Trupp is under Strahlenschutzüberwachung (#994), which shows the
+ /// STRAHLENSCHUTZ button.
+ public bool IsRadiationMonitored => _trupp.RadiationMonitoring;
+
+ /// What the Strahlenschutzüberwachung still waits for (#994): the dosimeter numbers
+ /// before IM EINSATZ, the Ablesewerte before the Einsatz is closed. Null once nothing is owed.
+ public string? RadiationHint =>
+ _trupp.LacksDosimeterNumbers ? "Dosimeter-Nr. fehlen"
+ : _trupp.AwaitsDoseReading ? "Ablesewert offen"
+ : null;
+
+ public bool HasRadiationHint => RadiationHint is not null;
+
+ /// Opens the Strahlenschutz dialog. Also on a closed Einsatz, to read what was recorded;
+ /// the dialog itself refuses to save there.
+ [RelayCommand]
+ private void OpenRadiation() => _onOpenRadiation?.Invoke();
[RelayCommand(CanExecute = nameof(CanStart))]
private void Start() => _onStart();
@@ -340,6 +362,8 @@ public void Refresh()
OnPropertyChanged(nameof(StatusDisplay));
OnPropertyChanged(nameof(CanAssignSafetyTrupp));
OnPropertyChanged(nameof(CanChangeTruppType));
+ OnPropertyChanged(nameof(RadiationHint));
+ OnPropertyChanged(nameof(HasRadiationHint));
StartCommand.NotifyCanExecuteChanged();
RecordPressureCommand.NotifyCanExecuteChanged();
WithdrawCommand.NotifyCanExecuteChanged();
@@ -355,6 +379,7 @@ public sealed partial class ScbaViewModel : ObservableObject, INarrowAware, IEnt
private readonly IClock _clock;
private readonly IAlarmService _alarm;
private readonly Action _onChanged;
+ private readonly Action? _openRadiationDialog;
private readonly IDisposable? _subscription;
private readonly HashSet _alarmLogged = new();
@@ -385,14 +410,26 @@ public sealed partial class ScbaViewModel : ObservableObject, INarrowAware, IEnt
private bool _maxDurationUserEdited;
+ // A number typed for a numbered Trupp-Art (#995) survives a Trupp registered elsewhere; only
+ // the suggestion moves on.
+ private bool _typeNumberUserEdited;
+
// Same idea for the Abfrage-Intervall, which otherwise defaults to a third of the Einsatzzeit
// (#78) -- a hand-typed interval must survive a later Einsatzzeit change.
private bool _controlIntervalUserEdited;
private bool _applyingDefault;
- public ScbaViewModel(IIncidentSession session, MasterDataSet masterData, IClock clock, ITicker ticker, IAlarmService alarm, Action onChanged)
+ public ScbaViewModel(
+ IIncidentSession session,
+ MasterDataSet masterData,
+ IClock clock,
+ ITicker ticker,
+ IAlarmService alarm,
+ Action onChanged,
+ Action? openRadiationDialog = null)
{
+ _openRadiationDialog = openRadiationDialog;
ArgumentNullException.ThrowIfNull(session);
ArgumentNullException.ThrowIfNull(masterData);
ArgumentNullException.ThrowIfNull(ticker);
@@ -410,6 +447,7 @@ public ScbaViewModel(IIncidentSession session, MasterDataSet masterData, IClock
_newReturnPressureBar = _settings.ReturnPressureBar;
_newEntryPressure = 300;
_newTruppNumber = session.Incident.NextFreeScbaTruppNumber();
+ _newTypeNumber = 1;
IsReadOnly = session.IsReadOnly;
_truppTypes = masterData.TruppTypes;
TruppTypeOptions = masterData.TruppTypes.Select(t => t.Name).ToArray();
@@ -475,8 +513,48 @@ public ScbaViewModel(IIncidentSession session, MasterDataSet masterData, IClock
[NotifyPropertyChangedFor(nameof(NewZweiterTruppmannError))]
[NotifyPropertyChangedFor(nameof(ErrorSummary))]
[NotifyPropertyChangedFor(nameof(RequiresThirdMember))]
+ [NotifyPropertyChangedFor(nameof(IsNamedByNumber))]
+ [NotifyPropertyChangedFor(nameof(NewTypeNumberError))]
private string _newDesignation = string.Empty;
+ ///
+ /// Whether the selected Trupp-Typ is called by a number rather than a Funkrufname (#995), per
+ /// its Stammdaten row. The form then shows NUMMER in place of FUNKRUFNAME and the Trupp is
+ /// registered as "CSA-Trupp 1". An unlisted designation is named by Funkrufname, as ever.
+ ///
+ public bool IsNamedByNumber =>
+ StammdatenCatalogue.Find(NewDesignation, _truppTypes)?.NamedByNumber == true;
+
+ ///
+ /// The number a numbered Trupp-Typ's Trupp is called by: suggested as the next one free for
+ /// that Trupp-Art in this Einsatz, and the Lagebuchführer's to overwrite (#995). Unlike
+ /// this is user-edited, so a taken number is refused with a
+ /// message rather than ever reaching the domain.
+ ///
+ [ObservableProperty]
+ [NotifyPropertyChangedFor(nameof(NewTypeNumberError))]
+ [NotifyPropertyChangedFor(nameof(ErrorSummary))]
+ private int _newTypeNumber;
+
+ partial void OnNewTypeNumberChanged(int value)
+ {
+ if (!_applyingDefault)
+ {
+ _typeNumberUserEdited = true;
+ }
+ }
+
+ // Asked only for a numbered Trupp-Art: the TRUPP-ART ComboBox writes null into NewDesignation
+ // when its selection is cleared on reset, despite the property's type, and the query must
+ // never see that.
+ private void ApplyDefaultTypeNumber()
+ {
+ var previous = _applyingDefault;
+ _applyingDefault = true;
+ NewTypeNumber = IsNamedByNumber ? _session.Incident.NextFreeTypeNumber(NewDesignation) : 1;
+ _applyingDefault = previous;
+ }
+
///
/// Whether the selected Trupp-Typ is crewed by three, according to the Stammdaten. Drives the
/// visibility of the third name box and, through CanAddTrupp, whether the form may be
@@ -568,6 +646,11 @@ partial void OnNewDesignationChanged(string value)
{
ApplyDefaultMaxDuration();
}
+
+ // Another Trupp-Art counts its own numbers, so a number typed for the previous one means
+ // nothing for this one.
+ _typeNumberUserEdited = false;
+ ApplyDefaultTypeNumber();
}
private void ApplyDefaultMaxDuration()
@@ -785,11 +868,19 @@ private void UpdateAlarm(bool newAlarmTripped)
/// Whether the Trupp-Art is still missing, once the operator has asked (#412).
/// Everything this form is still waiting on, on one line beneath its fields (#412).
public string? ErrorSummary => ValidationMessages.Summarize(
- NewDesignationError, NewTruppfuehrerError, NewTruppmannError, NewZweiterTruppmannError, NewEntryPressureError);
+ NewDesignationError, NewTypeNumberError, NewTruppfuehrerError, NewTruppmannError, NewZweiterTruppmannError, NewEntryPressureError);
public string? NewDesignationError =>
_errorsShown && string.IsNullOrWhiteSpace(NewDesignation) ? ValidationMessages.Required : null;
+ /// A numbered Trupp-Art's number, missing or already given to another Trupp of that
+ /// Trupp-Art in this Einsatz (#995). Silent for every other Trupp-Art, which has no number box.
+ public string? NewTypeNumberError =>
+ !_errorsShown || !IsNamedByNumber ? null
+ : NewTypeNumber <= 0 ? ValidationMessages.Required
+ : _session.Incident.IsTypeNumberInUse(NewDesignation, NewTypeNumber) ? ValidationMessages.TypeNumberInUse
+ : null;
+
/// Whether the Truppführer is still missing, once asked (#412).
public string? NewTruppfuehrerError =>
_errorsShown && string.IsNullOrWhiteSpace(NewTruppfuehrer) ? ValidationMessages.Required : null;
@@ -855,6 +946,7 @@ private bool Validate()
{
ShowErrors(true);
return NewDesignationError is null
+ && NewTypeNumberError is null
&& NewTruppfuehrerError is null
&& NewTruppmannError is null
&& NewZweiterTruppmannError is null
@@ -867,6 +959,7 @@ private void ShowErrors(bool shown)
_errorsShown = shown;
OnPropertyChanged(nameof(NewDesignationError));
OnPropertyChanged(nameof(ErrorSummary));
+ OnPropertyChanged(nameof(NewTypeNumberError));
OnPropertyChanged(nameof(NewTruppfuehrerError));
OnPropertyChanged(nameof(ErrorSummary));
OnPropertyChanged(nameof(NewTruppmannError));
@@ -894,7 +987,10 @@ private void AddTrupp()
var crew = BuildCrew();
var membersDisplay = string.Join(" / ", crew.Select(m => m.Name));
var designation = NewDesignation;
- var callSign = NewCallSign;
+
+ // A numbered Trupp-Art is called "CSA-Trupp 1" (#995). The name is copied into the
+ // Trupp's own Funkrufname here, so the record keeps it whatever the Stammdaten say later.
+ var callSign = IsNamedByNumber ? AtemschutzTrupp.NumberedCallSign(NewDesignation, NewTypeNumber) : NewCallSign;
var truppNumber = NewTruppNumber;
var entryPressure = NewEntryPressure;
var displayName = AtemschutzTrupp.FormatDisplayName(callSign, designation);
@@ -907,7 +1003,8 @@ private void AddTrupp()
task: null,
maxDurationMinutes: NewMaxDurationMinutes,
returnPressureBar: NewReturnPressureBar,
- pressureControlIntervalMinutes: NewControlIntervalMinutes);
+ pressureControlIntervalMinutes: NewControlIntervalMinutes,
+ radiationMonitoring: StammdatenCatalogue.Find(designation, _truppTypes)?.RadiationMonitoring == true);
_session.AddJournalEntry(
EtbDirection.System,
$"{displayName} bereitgestellt: {membersDisplay}, Einstiegsdruck {entryPressure} bar",
@@ -916,6 +1013,8 @@ private void AddTrupp()
_maxDurationUserEdited = false;
_controlIntervalUserEdited = false;
+
+ // _typeNumberUserEdited needs no reset here: clearing NewDesignation below does it.
NewDesignation = string.Empty;
NewTruppfuehrer = string.Empty;
NewTruppmann = string.Empty;
@@ -949,7 +1048,8 @@ private ScbaTruppRow CreateRow(AtemschutzTrupp trupp) =>
SafetyTruppHintFor(trupp),
CoveredTruppsFor(trupp),
TruppTypeChoicesFor(trupp),
- safetyTruppId => AssignSafetyTrupp(trupp.Id, safetyTruppId));
+ safetyTruppId => AssignSafetyTrupp(trupp.Id, safetyTruppId),
+ () => _openRadiationDialog?.Invoke(new RadiationDialogViewModel(_session, trupp.Id, _onChanged)));
/// The Trupp-Art flyout entries for one row (#835): today's Trupp-Arten, plus the
/// Trupp's own when the Stammdaten no longer list it, so the record is shown, never lost.
@@ -1267,6 +1367,13 @@ private void RefreshTrupps()
// is never user-edited, so there is nothing to clobber).
NewTruppNumber = _session.Incident.NextFreeScbaTruppNumber();
+ // The same for a numbered Trupp-Art's number (#995) -- but that one is user-edited, so a
+ // number somebody typed stays, and the press tells them if it has been taken meanwhile.
+ if (!_typeNumberUserEdited)
+ {
+ ApplyDefaultTypeNumber();
+ }
+
// Replaced only when the list really differs: swapping an ItemsSource under an open
// dropdown is what froze the Atemschutz picker in #408.
var callSigns = CallSignsOfForces(_session.Incident);
diff --git a/src/LageBuch.AppLogic/ViewModels/TruppTypeRow.cs b/src/LageBuch.AppLogic/ViewModels/TruppTypeRow.cs
index a6f2e7302..fbb1b7f4f 100644
--- a/src/LageBuch.AppLogic/ViewModels/TruppTypeRow.cs
+++ b/src/LageBuch.AppLogic/ViewModels/TruppTypeRow.cs
@@ -12,12 +12,15 @@ public sealed partial class TruppTypeRow : ObservableObject
{
private readonly Action _onChanged;
- public TruppTypeRow(string name, int memberCount, int maxDurationMinutes, Action onChanged)
+ public TruppTypeRow(
+ string name, int memberCount, int maxDurationMinutes, Action onChanged, bool namedByNumber = false, bool radiationMonitoring = false)
{
_onChanged = onChanged;
_name = name;
_memberCount = memberCount;
_maxDurationMinutes = maxDurationMinutes;
+ _namedByNumber = namedByNumber;
+ _radiationMonitoring = radiationMonitoring;
}
/// Lowest crew the view's NumericUpDown offers -- a Trupp is never one person.
@@ -42,9 +45,23 @@ public TruppTypeRow(string name, int memberCount, int maxDurationMinutes, Action
[ObservableProperty]
private int _maxDurationMinutes;
+ /// "Funkrufname aus Nummer" (#995): the Atemschutz form asks for a number instead of a
+ /// Funkrufname and names the Trupp after its type, "CSA-Trupp 1".
+ [ObservableProperty]
+ private bool _namedByNumber;
+
+ /// Strahlenschutzüberwachung (#994): the Trupp's crew get dosimeter, Maske and PA
+ /// numbers and an Alarmdosimeter Ablesewert.
+ [ObservableProperty]
+ private bool _radiationMonitoring;
+
partial void OnNameChanged(string value) => _onChanged();
partial void OnMemberCountChanged(int value) => _onChanged();
partial void OnMaxDurationMinutesChanged(int value) => _onChanged();
+
+ partial void OnNamedByNumberChanged(bool value) => _onChanged();
+
+ partial void OnRadiationMonitoringChanged(bool value) => _onChanged();
}
diff --git a/src/LageBuch.AppLogic/ViewModels/TruppTypesSection.cs b/src/LageBuch.AppLogic/ViewModels/TruppTypesSection.cs
index ec083cfa9..c8eb2626d 100644
--- a/src/LageBuch.AppLogic/ViewModels/TruppTypesSection.cs
+++ b/src/LageBuch.AppLogic/ViewModels/TruppTypesSection.cs
@@ -20,13 +20,14 @@ public TruppTypesSection(string title, IEnumerable truppTypes, Action
{
_onChanged = onChanged;
Rows = new ObservableCollection(
- truppTypes.Select(t => NewRow(t.Name, t.MemberCount, t.MaxDurationMinutes)));
+ truppTypes.Select(t => NewRow(t.Name, t.MemberCount, t.MaxDurationMinutes, t.NamedByNumber, t.RadiationMonitoring)));
}
public ObservableCollection Rows { get; }
- private TruppTypeRow NewRow(string name, int memberCount, int maxDurationMinutes) =>
- new(name, memberCount, maxDurationMinutes, _onChanged);
+ private TruppTypeRow NewRow(
+ string name, int memberCount, int maxDurationMinutes, bool namedByNumber = false, bool radiationMonitoring = false) =>
+ new(name, memberCount, maxDurationMinutes, _onChanged, namedByNumber, radiationMonitoring);
[RelayCommand]
private void Add()
@@ -73,7 +74,9 @@ public IReadOnlyList ToValues()
result.Add(new TruppType(
name,
TruppType.ClampMemberCount(row.MemberCount),
- TruppType.ClampMaxDurationMinutes(row.MaxDurationMinutes)));
+ TruppType.ClampMaxDurationMinutes(row.MaxDurationMinutes),
+ row.NamedByNumber,
+ row.RadiationMonitoring));
}
}
diff --git a/src/LageBuch.AppLogic/ViewModels/ValidationMessages.cs b/src/LageBuch.AppLogic/ViewModels/ValidationMessages.cs
index 94b343939..31353f117 100644
--- a/src/LageBuch.AppLogic/ViewModels/ValidationMessages.cs
+++ b/src/LageBuch.AppLogic/ViewModels/ValidationMessages.cs
@@ -49,6 +49,10 @@ public static class ValidationMessages
/// An Ausgabe without the person it went to, which nobody could ask back for.
public const string IssuedToRequired = "Ausgegeben an: Name eingeben";
+ /// A numbered Trupp's number already names another Trupp of the same Trupp-Art in
+ /// this Einsatz (#995) -- two "CSA-Trupp 1" on the radio are one too many.
+ public const string TypeNumberInUse = "Nummer bereits vergeben";
+
/// The Wache a Kräfte row belongs to, without which the row reports nobody.
public const string BrigadeRequired = "Wache eingeben";
diff --git a/src/LageBuch.Documents/Sections/AtemschutzSection.cs b/src/LageBuch.Documents/Sections/AtemschutzSection.cs
index 8fa74f94e..73bbc2dde 100644
--- a/src/LageBuch.Documents/Sections/AtemschutzSection.cs
+++ b/src/LageBuch.Documents/Sections/AtemschutzSection.cs
@@ -84,6 +84,15 @@ public static void Compose(IContainer container, Incident incident, DateTimeOffs
}
cell.Item().Text(DetailLine(trupp, asOf)).FontSize(8).FontColor(Colors.Grey.Darken1);
+
+ // #994: one line per crew member of a Strahlenschutztrupp. A dosimeter
+ // declared missing breaks the documentation chain, so that line is not grey
+ // but dark red and bold: it is what the Bericht is read for afterwards.
+ foreach (var (text, gap) in RadiationLines(trupp))
+ {
+ var (color, weight) = RadiationLineStyle(gap);
+ cell.Item().DefaultTextStyle(style => style.FontSize(8).FontColor(color).Weight(weight)).Text(text);
+ }
});
}
});
@@ -109,6 +118,31 @@ public static string DetailLine(AtemschutzTrupp trupp, DateTimeOffset asOf)
return $"{status} · Messreihe: {series}";
}
+ ///
+ /// The Strahlenschutzüberwachung of a Strahlenschutztrupp (#994), one line per crew member:
+ /// "Strahlenschutz Müller (Truppführer): OSL-Dosimeter 4711, …, PA 3 · Ablesewert 0,12 mSv".
+ /// Gap marks a line with a dosimeter declared missing. Empty for any other Trupp.
+ ///
+ public static IReadOnlyList<(string Text, bool Gap)> RadiationLines(AtemschutzTrupp trupp)
+ {
+ ArgumentNullException.ThrowIfNull(trupp);
+ var lines = new List<(string Text, bool Gap)>();
+ foreach (var m in trupp.Members)
+ {
+ if (m.Radiation is { } r)
+ {
+ lines.Add(($"Strahlenschutz {m.Name} ({m.RoleDisplay}): {r.NumbersDisplay} · {r.ReadingDisplay}", r.HasGap));
+ }
+ }
+
+ return lines;
+ }
+
+ /// How a Strahlenschutz line prints (#994): grey like the other sub-lines, or dark red
+ /// and semi-bold when a dosimeter is declared missing.
+ public static (Color Color, FontWeight Weight) RadiationLineStyle(bool gap) =>
+ gap ? (Colors.Red.Darken3, FontWeight.SemiBold) : (Colors.Grey.Darken1, FontWeight.Normal);
+
private static string Reading(PressureReading r) =>
r.Location is null
? $"{Formatting.TimeOfDay(r.Time)} {r.Bar} bar"
diff --git a/src/LageBuch.Domain/Atemschutz/AtemschutzTrupp.cs b/src/LageBuch.Domain/Atemschutz/AtemschutzTrupp.cs
index 2e7eff9f5..a9b089e45 100644
--- a/src/LageBuch.Domain/Atemschutz/AtemschutzTrupp.cs
+++ b/src/LageBuch.Domain/Atemschutz/AtemschutzTrupp.cs
@@ -87,9 +87,40 @@ private AtemschutzTrupp()
public string DisplayName => FormatDisplayName(CallSign, Designation);
/// Same formatting as , usable before an instance exists —
- /// e.g. to compose the registration ETB line from form inputs, before the mutation commits.
- public static string FormatDisplayName(string? callSign, string designation) =>
- string.IsNullOrWhiteSpace(callSign) ? designation : $"{callSign.Trim()} · {designation}";
+ /// e.g. to compose the registration ETB line from form inputs, before the mutation commits.
+ ///
+ /// A Funkrufname that already names the Trupp-Art -- "CSA-Trupp 1" for a CSA-Trupp, the name
+ /// a Trupp-Typ numbered per gets (#995) -- stands alone: adding
+ /// the designation again would read "CSA-Trupp 1 · CSA-Trupp".
+ ///
+ ///
+ public static string FormatDisplayName(string? callSign, string designation)
+ {
+ ArgumentNullException.ThrowIfNull(designation);
+ if (string.IsNullOrWhiteSpace(callSign))
+ {
+ return designation;
+ }
+
+ var name = callSign.Trim();
+ return NamesTruppArt(name, designation.Trim()) ? name : $"{name} · {designation}";
+ }
+
+ ///
+ /// The Funkrufname of a Trupp named by its number rather than a vehicle (#995): "CSA-Trupp 1".
+ /// Which Trupp-Typen are named this way is Stammdaten; the name is composed here so the form,
+ /// the free-number query and the display rule above can never disagree about its shape.
+ ///
+ public static string NumberedCallSign(string designation, int number)
+ {
+ ArgumentNullException.ThrowIfNull(designation);
+ return $"{designation.Trim()} {number.ToString(System.Globalization.CultureInfo.InvariantCulture)}";
+ }
+
+ private static bool NamesTruppArt(string callSign, string designation) =>
+ designation.Length > 0
+ && (string.Equals(callSign, designation, StringComparison.Ordinal)
+ || callSign.StartsWith(designation + " ", StringComparison.Ordinal));
///
/// The crew, in position order: between and
@@ -133,6 +164,28 @@ public static string FormatDisplayName(string? callSign, string designation) =>
public int PressureControlIntervalMinutes { get; private set; }
+ ///
+ /// Whether this Trupp is under Strahlenschutzüberwachung (#994): every crew member then carries
+ /// a . Copied from the Trupp-Typ at , never
+ /// looked up again, so a Trupp-Typ edited in the Stammdaten later cannot take it away.
+ ///
+ public bool RadiationMonitoring { get; private init; }
+
+ ///
+ /// A Strahlenschutztrupp that may not go under Atemschutz yet: a crew member's OSL-Dosimeter or
+ /// Alarmdosimeter has neither a number nor "nicht vorhanden" (#994).
+ ///
+ public bool LacksDosimeterNumbers =>
+ RadiationMonitoring && _members.Any(m => m.Radiation?.HasDosimeterNumbers != true);
+
+ ///
+ /// A Strahlenschutztrupp that went under Atemschutz and still owes an Alarmdosimeter answer --
+ /// a reading or "nicht vorhanden" -- for a crew member (#994). The Einsatz cannot be closed while
+ /// one does. A Trupp that never started has no dose to report.
+ ///
+ public bool AwaitsDoseReading =>
+ RadiationMonitoring && HasStarted && _members.Any(m => m.Radiation?.HasAlarmAnswer != true);
+
/// When the Trupp began its Rückzug. Null before withdrawing, and while still waiting/active.
public DateTimeOffset? WithdrawTime { get; private set; }
@@ -151,7 +204,8 @@ public static AtemschutzTrupp Register(
string? task = null,
int maxDurationMinutes = DefaultMaxDurationMinutes,
int returnPressureBar = DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = DefaultPressureControlIntervalMinutes)
+ int pressureControlIntervalMinutes = DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false)
{
ArgumentNullException.ThrowIfNull(members);
if (string.IsNullOrWhiteSpace(designation))
@@ -183,8 +237,15 @@ public static AtemschutzTrupp Register(
MaxDurationMinutes = maxDurationMinutes,
ReturnPressureBar = returnPressureBar,
PressureControlIntervalMinutes = pressureControlIntervalMinutes,
+ RadiationMonitoring = radiationMonitoring,
};
- trupp._members.AddRange(crew);
+
+ // Every crew member of a Strahlenschutztrupp carries a record from the start, and nobody
+ // else does: "under Strahlenschutzüberwachung" is a property of the Trupp, not of a person.
+ trupp._members.AddRange(crew.Select(m => m with
+ {
+ Radiation = radiationMonitoring ? m.Radiation ?? RadiationRecord.Empty : null,
+ }));
return trupp;
}
@@ -237,7 +298,8 @@ public static AtemschutzTrupp Rehydrate(
int pressureControlIntervalMinutes,
DateTimeOffset? exitTime,
IEnumerable readings,
- Guid? safetyTruppId = null)
+ Guid? safetyTruppId = null,
+ bool radiationMonitoring = false)
{
var trupp = new AtemschutzTrupp
{
@@ -255,6 +317,7 @@ public static AtemschutzTrupp Rehydrate(
PressureControlIntervalMinutes = pressureControlIntervalMinutes,
ExitTime = exitTime,
SafetyTruppId = safetyTruppId,
+ RadiationMonitoring = radiationMonitoring,
};
// Rehydrate deliberately does not re-run ValidateCrew: a stored Trupp is history, and
@@ -325,9 +388,39 @@ public void Start(DateTimeOffset time)
throw new InvalidOperationException("Trupp ist bereits unter Atemschutz.");
}
+ // #994: the dose a Strahlenschutztrupp takes in has to be traceable to a dosimeter, so the
+ // numbers come before the Trupp goes under Atemschutz, not after.
+ if (LacksDosimeterNumbers)
+ {
+ throw new InvalidOperationException(
+ "Dosimeter-Nummern fehlen: erst eintragen oder als nicht vorhanden bestätigen.");
+ }
+
StartTime = time;
}
+ ///
+ /// Records the Strahlenschutzüberwachung of the crew member in (#994),
+ /// replacing what was there. Accepted in every state, abgenommen included: the Dekon-Platz often
+ /// reports the Ablesewert to the ELW well after the Trupp is out. The caller writes the ETB line.
+ ///
+ public void RecordRadiation(TruppRole role, RadiationRecord record)
+ {
+ ArgumentNullException.ThrowIfNull(record);
+ if (!RadiationMonitoring)
+ {
+ throw new InvalidOperationException("Dieser Trupp steht nicht unter Strahlenschutzüberwachung.");
+ }
+
+ var index = _members.FindIndex(m => m.Role == role);
+ if (index < 0)
+ {
+ throw new ArgumentException("Diese Truppfunktion ist nicht besetzt.", nameof(role));
+ }
+
+ _members[index] = _members[index] with { Radiation = record };
+ }
+
///
/// Records a Druckkontrolle and, optionally, where the Trupp was at the time. A blank
/// records none.
diff --git a/src/LageBuch.Domain/Atemschutz/DoseReading.cs b/src/LageBuch.Domain/Atemschutz/DoseReading.cs
new file mode 100644
index 000000000..9150ce20e
--- /dev/null
+++ b/src/LageBuch.Domain/Atemschutz/DoseReading.cs
@@ -0,0 +1,52 @@
+namespace LageBuch.Domain.Atemschutz;
+
+///
+/// The unit an Alarmdosimeter reading is written down in (#994). Both occur: a direct-reading
+/// dosimeter shows µSv for everyday doses and mSv once they climb. The ordinals are a storage
+/// contract, so they may be appended to but never renumbered.
+///
+public enum DoseUnit
+{
+ MilliSievert = 0,
+ MicroSievert = 1,
+}
+
+///
+/// The Ablesewert of an Alarmdosimeter, kept exactly as it was read off the display: value and unit
+/// together, never converted (#994). Converting would put a number in the record that nobody saw.
+///
+public sealed record DoseReading
+{
+ ///
+ /// The largest value accepted, in either unit. Far beyond anything an Einsatz reads; it only
+ /// stops a typo or a hostile file from carrying a number no display shows.
+ ///
+ public const decimal MaxValue = 100_000m;
+
+ public DoseReading(decimal value, DoseUnit unit)
+ {
+ if (value < 0 || value > MaxValue)
+ {
+ throw new ArgumentOutOfRangeException(nameof(value), "Der Ablesewert muss zwischen 0 und 100.000 liegen.");
+ }
+
+ if (!Enum.IsDefined(unit))
+ {
+ throw new ArgumentOutOfRangeException(nameof(unit), "Unbekannte Einheit.");
+ }
+
+ Value = value;
+ Unit = unit;
+ }
+
+ public decimal Value { get; }
+
+ public DoseUnit Unit { get; }
+
+ /// "mSv" or "µSv".
+ public static string UnitLabel(DoseUnit unit) => unit == DoseUnit.MicroSievert ? "µSv" : "mSv";
+
+ /// The reading as the display showed it: "0,12 mSv", "35 µSv". Up to three decimals,
+ /// since a small mSv reading is a fraction of one.
+ public string Display => $"{Value.ToString("0.###", Formatting.NumberFormat)} {UnitLabel(Unit)}";
+}
diff --git a/src/LageBuch.Domain/Atemschutz/RadiationRecord.cs b/src/LageBuch.Domain/Atemschutz/RadiationRecord.cs
new file mode 100644
index 000000000..45dbedc9c
--- /dev/null
+++ b/src/LageBuch.Domain/Atemschutz/RadiationRecord.cs
@@ -0,0 +1,138 @@
+namespace LageBuch.Domain.Atemschutz;
+
+///
+/// The Strahlenschutzüberwachung of one Einsatzkraft in a Strahlenschutztrupp (#994): the numbers
+/// of the two dosimeters, the Maske and the PA they carry, and the Alarmdosimeter's Ablesewert once
+/// it is reported.
+///
+/// A dosimeter that is not there is an explicit answer, or
+/// , never just an empty field: the record has to say whether
+/// the chain of documentation broke or merely has not been filled in yet. A number can stand
+/// beside "missing" -- a dosimeter lost under Atemschutz was still handed out under that number.
+///
+///
+public sealed record RadiationRecord
+{
+ /// The longest number kept for a dosimeter, Maske or PA.
+ public const int MaxNumberLength = 50;
+
+ public RadiationRecord(
+ string? oslDosimeterNumber = null,
+ bool oslDosimeterMissing = false,
+ string? alarmDosimeterNumber = null,
+ bool alarmDosimeterMissing = false,
+ string? maskNumber = null,
+ string? paNumber = null,
+ DoseReading? alarmReading = null)
+ {
+ OslDosimeterNumber = Number(oslDosimeterNumber, nameof(oslDosimeterNumber));
+ OslDosimeterMissing = oslDosimeterMissing;
+ AlarmDosimeterNumber = Number(alarmDosimeterNumber, nameof(alarmDosimeterNumber));
+ AlarmDosimeterMissing = alarmDosimeterMissing;
+ MaskNumber = Number(maskNumber, nameof(maskNumber));
+ PaNumber = Number(paNumber, nameof(paNumber));
+ if (alarmDosimeterMissing && alarmReading is not null)
+ {
+ throw new ArgumentException(
+ "Ein Alarmdosimeter, das nicht vorhanden ist, hat keinen Ablesewert.", nameof(alarmReading));
+ }
+
+ AlarmReading = alarmReading;
+ }
+
+ /// Nothing recorded yet: what a crew member of a Strahlenschutztrupp starts with.
+ public static RadiationRecord Empty { get; } = new();
+
+ public string? OslDosimeterNumber { get; }
+
+ public bool OslDosimeterMissing { get; }
+
+ public string? AlarmDosimeterNumber { get; }
+
+ public bool AlarmDosimeterMissing { get; }
+
+ public string? MaskNumber { get; }
+
+ public string? PaNumber { get; }
+
+ public DoseReading? AlarmReading { get; }
+
+ /// Both dosimeters are accounted for: each has a number or is declared missing. What
+ /// the Trupp needs before it goes under Atemschutz.
+ public bool HasDosimeterNumbers =>
+ (OslDosimeterMissing || OslDosimeterNumber is not null)
+ && (AlarmDosimeterMissing || AlarmDosimeterNumber is not null);
+
+ /// The Alarmdosimeter has its final answer: a reading, or "nicht vorhanden". What the
+ /// Einsatz needs before it is closed.
+ public bool HasAlarmAnswer => AlarmDosimeterMissing || AlarmReading is not null;
+
+ ///
+ /// A record from somewhere this app did not write it just now: a .lagebuch someone handed over,
+ /// or a host's snapshot. Built leniently, the way Rehydrate treats a Trupp: one implausible value
+ /// costs that value, never the whole Einsatz. A number over the cap is cut to it; a reading that
+ /// is out of range or names no known unit is dropped, and so is one beside an Alarmdosimeter
+ /// declared missing. A command a client sends goes through the checking constructor instead.
+ ///
+ public static RadiationRecord FromUntrusted(
+ string? oslDosimeterNumber,
+ bool oslDosimeterMissing,
+ string? alarmDosimeterNumber,
+ bool alarmDosimeterMissing,
+ string? maskNumber,
+ string? paNumber,
+ decimal? doseValue,
+ int? doseUnit) =>
+ new(
+ Capped(oslDosimeterNumber),
+ oslDosimeterMissing,
+ Capped(alarmDosimeterNumber),
+ alarmDosimeterMissing,
+ Capped(maskNumber),
+ Capped(paNumber),
+ alarmDosimeterMissing ? null : Dose(doseValue, doseUnit));
+
+ /// "OSL-Dosimeter 4711, Alarmdosimeter 0815, Maske 12, PA 3", with "—" for an empty
+ /// number and "(nicht vorhanden)" after a dosimeter declared missing. Shared by the ETB line and
+ /// the Bericht so both say it the same way.
+ public string NumbersDisplay =>
+ $"OSL-Dosimeter {Dosimeter(OslDosimeterNumber, OslDosimeterMissing)}, "
+ + $"Alarmdosimeter {Dosimeter(AlarmDosimeterNumber, AlarmDosimeterMissing)}, "
+ + $"Maske {MaskNumber ?? "—"}, PA {PaNumber ?? "—"}";
+
+ /// The Alarmdosimeter's answer for the Bericht: the reading, "nicht vorhanden", or
+ /// "offen" while it is still owed.
+ public string ReadingDisplay =>
+ AlarmDosimeterMissing ? "Ablesewert: nicht vorhanden"
+ : AlarmReading is { } reading ? $"Ablesewert {reading.Display}"
+ : "Ablesewert offen";
+
+ /// A dosimeter declared missing: the chain of documentation has a gap.
+ public bool HasGap => OslDosimeterMissing || AlarmDosimeterMissing;
+
+ /// This record with as the Ablesewert, checked like any other.
+ public RadiationRecord WithAlarmReading(DoseReading? reading) => new(
+ OslDosimeterNumber, OslDosimeterMissing, AlarmDosimeterNumber, AlarmDosimeterMissing, MaskNumber, PaNumber, reading);
+
+ private static string Dosimeter(string? number, bool missing) =>
+ missing ? $"{number ?? "—"} (nicht vorhanden)" : number ?? "—";
+
+ private static string? Capped(string? value) =>
+ value is { Length: > MaxNumberLength } ? value[..MaxNumberLength] : value;
+
+ private static DoseReading? Dose(decimal? value, int? unit) =>
+ value is { } v && unit is { } u && Enum.IsDefined((DoseUnit)u) && v >= 0 && v <= DoseReading.MaxValue
+ ? new DoseReading(v, (DoseUnit)u)
+ : null;
+
+ private static string? Number(string? value, string paramName)
+ {
+ var trimmed = string.IsNullOrWhiteSpace(value) ? null : value.Trim();
+ if (trimmed is { Length: > MaxNumberLength })
+ {
+ throw new ArgumentException($"Eine Nummer darf höchstens {MaxNumberLength} Zeichen lang sein.", paramName);
+ }
+
+ return trimmed;
+ }
+}
diff --git a/src/LageBuch.Domain/Atemschutz/TruppMember.cs b/src/LageBuch.Domain/Atemschutz/TruppMember.cs
index 39e162a44..00f9ee907 100644
--- a/src/LageBuch.Domain/Atemschutz/TruppMember.cs
+++ b/src/LageBuch.Domain/Atemschutz/TruppMember.cs
@@ -16,8 +16,11 @@ public enum TruppRole
ZweiterTruppmann = 2,
}
-/// One named person in a Trupp, addressable by their position.
-public sealed record TruppMember(TruppRole Role, string Name)
+///
+/// One named person in a Trupp, addressable by their position. is their
+/// Strahlenschutzüberwachung (#994) -- present exactly when the Trupp is under it, null otherwise.
+///
+public sealed record TruppMember(TruppRole Role, string Name, RadiationRecord? Radiation = null)
{
public static TruppMember Create(TruppRole role, string name)
{
diff --git a/src/LageBuch.Domain/Incident.cs b/src/LageBuch.Domain/Incident.cs
index 377d72670..9e0196a1d 100644
--- a/src/LageBuch.Domain/Incident.cs
+++ b/src/LageBuch.Domain/Incident.cs
@@ -375,6 +375,15 @@ public void Close(IClock clock, SessionOperator closedBy)
ArgumentNullException.ThrowIfNull(closedBy);
EnsureOpen();
+ // #994: a closed Einsatz is read-only, so an Ablesewert missing now could never be added.
+ // Refused here as well as in the view model, because a joined client's close reaches the
+ // host as a command.
+ if (ScbaTruppsAwaitingDoseReading is { Count: > 0 } awaiting)
+ {
+ throw new InvalidOperationException(
+ "Ablesewerte fehlen: " + string.Join(", ", awaiting.Select(t => t.DisplayName)) + ".");
+ }
+
// Must precede the state flip — a closed incident rejects journal writes.
AppendSystemEntry(clock, closedBy, "Einsatz abgeschlossen");
@@ -1694,6 +1703,21 @@ public void RemoveForceUnit(IClock clock, SessionOperator op, Guid unitId)
public int NextFreeScbaTruppNumber() =>
Enumerable.Range(1, _scbaTrupps.Count + 1).First(n => _scbaTrupps.All(t => t.TruppNumber != n));
+ /// The smallest positive number not yet in a Funkrufname of the shape
+ /// gives for ,
+ /// counted per Trupp-Art (#995): two Angriffstrupps before it leave the first CSA-Trupp "1".
+ /// An abgenommen Trupp keeps its number. Pure query, like .
+ public int NextFreeTypeNumber(string designation) =>
+ Enumerable.Range(1, _scbaTrupps.Count + 1).First(n => !IsTypeNumberInUse(designation, n));
+
+ /// Whether a Trupp of this incident, running or abgenommen, already carries the
+ /// Funkrufname composes from these two.
+ public bool IsTypeNumberInUse(string designation, int number)
+ {
+ var callSign = AtemschutzTrupp.NumberedCallSign(designation, number);
+ return _scbaTrupps.Any(t => string.Equals(t.CallSign, callSign, StringComparison.Ordinal));
+ }
+
///
/// The running assignment holding in , or null
/// when that slot is free. A pure query — it decides nothing and writes nothing, the same stance
@@ -1797,7 +1821,8 @@ public AtemschutzTrupp AddScbaTrupp(
string? task = null,
int maxDurationMinutes = AtemschutzTrupp.DefaultMaxDurationMinutes,
int returnPressureBar = AtemschutzTrupp.DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes)
+ int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false)
{
EnsureOpen();
ArgumentNullException.ThrowIfNull(clock);
@@ -1817,11 +1842,27 @@ public AtemschutzTrupp AddScbaTrupp(
task,
maxDurationMinutes,
returnPressureBar,
- pressureControlIntervalMinutes);
+ pressureControlIntervalMinutes,
+ radiationMonitoring);
_scbaTrupps.Add(trupp);
return trupp;
}
+ /// Records one crew member's Strahlenschutzüberwachung (#994); see
+ /// . The ETB line is written by the caller.
+ public AtemschutzTrupp RecordScbaRadiation(Guid truppId, TruppRole role, RadiationRecord record)
+ {
+ EnsureOpen();
+ var trupp = FindScbaTrupp(truppId);
+ trupp.RecordRadiation(role, record);
+ return trupp;
+ }
+
+ /// The Strahlenschutztrupps still owing an Alarmdosimeter answer (#994), in Trupp
+ /// order. While any does, the Einsatz cannot be closed.
+ public IReadOnlyList ScbaTruppsAwaitingDoseReading =>
+ _scbaTrupps.Where(t => t.AwaitsDoseReading).OrderBy(t => t.TruppNumber).ToList();
+
public AtemschutzTrupp StartScbaTrupp(IClock clock, Guid truppId)
{
EnsureOpen();
diff --git a/src/LageBuch.Persistence/IncidentRepository.cs b/src/LageBuch.Persistence/IncidentRepository.cs
index 975868a14..02a1517e8 100644
--- a/src/LageBuch.Persistence/IncidentRepository.cs
+++ b/src/LageBuch.Persistence/IncidentRepository.cs
@@ -252,7 +252,7 @@ private static void WriteScbaTrupps(InsertCommands inserts, Incident incident)
var t = incident.ScbaTrupps[i];
Run(
inserts,
- "INSERT INTO scba_trupps (id, ordinal, trupp_number, designation, call_sign, task, registered_at, start_time, entry_pressure, withdraw_time, max_duration_minutes, return_pressure_bar, pressure_control_interval_minutes, exit_time, safety_trupp_id) " + "VALUES ($id,$o,$num,$des,$cs,$task,$reg,$start,$ep,$wd,$max,$ret,$interval,$exit,$safety);",
+ "INSERT INTO scba_trupps (id, ordinal, trupp_number, designation, call_sign, task, registered_at, start_time, entry_pressure, withdraw_time, max_duration_minutes, return_pressure_bar, pressure_control_interval_minutes, exit_time, safety_trupp_id, radiation_monitoring) " + "VALUES ($id,$o,$num,$des,$cs,$task,$reg,$start,$ep,$wd,$max,$ret,$interval,$exit,$safety,$rad);",
p =>
{
p("$id", t.Id.ToString());
@@ -270,6 +270,7 @@ private static void WriteScbaTrupps(InsertCommands inserts, Incident incident)
p("$interval", t.PressureControlIntervalMinutes);
p("$exit", (object?)t.ExitTime?.ToString(Iso) ?? DBNull.Value);
p("$safety", (object?)t.SafetyTruppId?.ToString() ?? DBNull.Value);
+ p("$rad", t.RadiationMonitoring ? 1 : 0);
});
for (var j = 0; j < t.Members.Count; j++)
@@ -277,13 +278,23 @@ private static void WriteScbaTrupps(InsertCommands inserts, Incident incident)
var member = t.Members[j];
Run(
inserts,
- "INSERT INTO scba_trupp_members (trupp_id, ordinal, role, name) VALUES ($tid,$o,$role,$name);",
+ "INSERT INTO scba_trupp_members (trupp_id, ordinal, role, name, has_radiation, osl_number, osl_missing, alarm_number, alarm_missing, mask_number, pa_number, dose_value, dose_unit) VALUES ($tid,$o,$role,$name,$hasrad,$osl,$oslmiss,$alarm,$alarmmiss,$mask,$pa,$dose,$unit);",
p =>
{
+ var rad = member.Radiation;
p("$tid", t.Id.ToString());
p("$o", j);
p("$role", (int)member.Role);
p("$name", member.Name);
+ p("$hasrad", rad is null ? 0 : 1);
+ p("$osl", (object?)rad?.OslDosimeterNumber ?? DBNull.Value);
+ p("$oslmiss", rad?.OslDosimeterMissing == true ? 1 : 0);
+ p("$alarm", (object?)rad?.AlarmDosimeterNumber ?? DBNull.Value);
+ p("$alarmmiss", rad?.AlarmDosimeterMissing == true ? 1 : 0);
+ p("$mask", (object?)rad?.MaskNumber ?? DBNull.Value);
+ p("$pa", (object?)rad?.PaNumber ?? DBNull.Value);
+ p("$dose", (object?)rad?.AlarmReading?.Value.ToString(CultureInfo.InvariantCulture) ?? DBNull.Value);
+ p("$unit", (object?)(int?)rad?.AlarmReading?.Unit ?? DBNull.Value);
});
}
@@ -814,10 +825,10 @@ public static Incident Load(string path)
var membersByTrupp = ReadAll(
cn,
- "SELECT trupp_id, role, name FROM scba_trupp_members ORDER BY ordinal;",
+ "SELECT trupp_id, role, name, has_radiation, osl_number, osl_missing, alarm_number, alarm_missing, mask_number, pa_number, dose_value, dose_unit FROM scba_trupp_members ORDER BY ordinal;",
r => (TruppId: Guid.Parse(r.GetString(0)),
Member: new Domain.Atemschutz.TruppMember(
- (Domain.Atemschutz.TruppRole)r.GetInt32(1), r.GetString(2))))
+ (Domain.Atemschutz.TruppRole)r.GetInt32(1), r.GetString(2), ReadRadiation(r))))
.GroupBy(x => x.TruppId)
.ToDictionary(g => g.Key, g => g.Select(x => x.Member).ToList());
@@ -831,7 +842,7 @@ public static Incident Load(string path)
var scbaTrupps = ReadAll(
cn,
- "SELECT id, trupp_number, designation, call_sign, task, registered_at, start_time, withdraw_time, entry_pressure, max_duration_minutes, return_pressure_bar, pressure_control_interval_minutes, exit_time, safety_trupp_id FROM scba_trupps ORDER BY ordinal;",
+ "SELECT id, trupp_number, designation, call_sign, task, registered_at, start_time, withdraw_time, entry_pressure, max_duration_minutes, return_pressure_bar, pressure_control_interval_minutes, exit_time, safety_trupp_id, radiation_monitoring FROM scba_trupps ORDER BY ordinal;",
r =>
{
var id = Guid.Parse(r.GetString(0));
@@ -851,7 +862,8 @@ public static Incident Load(string path)
r.GetInt32(11),
NullableDate(r, 12),
readingsByTrupp.TryGetValue(id, out var rs) ? rs : Enumerable.Empty(),
- NullableGuid(r, 13));
+ NullableGuid(r, 13),
+ r.GetInt32(14) != 0);
});
var audit = ReadAll(
@@ -1125,6 +1137,23 @@ private static DateTimeOffset ParseDate(string s) =>
private static int? NullableInt(SqliteDataReader r, int i) => r.IsDBNull(i) ? null : r.GetInt32(i);
+ /// A crew member's Strahlenschutzüberwachung (#994) from columns 3..11 of the member
+ /// query, or null when the member carries none. A file is untrusted, so the record is built
+ /// through ; a dose that does not
+ /// even parse as a number is simply no reading.
+ private static Domain.Atemschutz.RadiationRecord? ReadRadiation(SqliteDataReader r) =>
+ r.GetInt32(3) == 0
+ ? null
+ : Domain.Atemschutz.RadiationRecord.FromUntrusted(
+ Str(r, 4),
+ r.GetInt32(5) != 0,
+ Str(r, 6),
+ r.GetInt32(7) != 0,
+ Str(r, 8),
+ Str(r, 9),
+ decimal.TryParse(Str(r, 10), NumberStyles.Number, CultureInfo.InvariantCulture, out var dose) ? dose : null,
+ NullableInt(r, 11));
+
// A coordinate is only taken as a number. A hostile file can store text in a REAL column, and a
// position that does not read costs the mark on the Lagekarte, not the Einsatz.
private static double? NullableDouble(SqliteDataReader r, int i) => Real(r.IsDBNull(i) ? null : r.GetValue(i));
diff --git a/src/LageBuch.Persistence/MasterData/MasterDataSet.cs b/src/LageBuch.Persistence/MasterData/MasterDataSet.cs
index eee862383..3954619e1 100644
--- a/src/LageBuch.Persistence/MasterData/MasterDataSet.cs
+++ b/src/LageBuch.Persistence/MasterData/MasterDataSet.cs
@@ -753,8 +753,20 @@ public sealed record Device(string Name, int Count)
/// an ArgumentException escaping it would leak an open sync connection. Every entrance clamps
/// instead; see and the Stammdaten editor.
///
+///
+/// says the Trupp is called by a number rather than a vehicle's
+/// Funkrufname (#995): the Atemschutz form asks for that number and names the Trupp
+/// "CSA-Trupp 1". It is a setting on the row, not a check on the name, for the same reason the
+/// crew size is.
+///
+///
+/// puts the Trupp under Strahlenschutzüberwachung (#994): every
+/// crew member then gets dosimeter, Maske and PA numbers and an Alarmdosimeter Ablesewert. The
+/// Trupp copies the flag when it is registered.
+///
///
-public sealed record TruppType(string Name, int MemberCount, int MaxDurationMinutes)
+public sealed record TruppType(
+ string Name, int MemberCount, int MaxDurationMinutes, bool NamedByNumber = false, bool RadiationMonitoring = false)
{
/// An ordinary two-person Trupp on the standard Einsatzzeit -- the shape every type
/// has until someone says otherwise. Keeps the many construction sites to just a name.
@@ -854,7 +866,10 @@ public static TruppType ToTruppType(string name, LegacyEinsatzzeiten einsatzzeit
var trimmed = name?.Trim() ?? string.Empty;
if (Matches(trimmed, ChemicalName))
{
- return new TruppType(trimmed, AtemschutzTrupp.MaxMemberCount, einsatzzeiten.Chemical);
+ // Numbered too (#995), as MasterDataStore's one-time flag migration numbers an
+ // existing CSA-Trupp, so both entrances still end up with identical rows.
+ return new TruppType(
+ trimmed, AtemschutzTrupp.MaxMemberCount, einsatzzeiten.Chemical, NamedByNumber: true);
}
return Matches(trimmed, LpaName)
@@ -862,6 +877,11 @@ public static TruppType ToTruppType(string name, LegacyEinsatzzeiten einsatzzeit
: new TruppType(trimmed, AtemschutzTrupp.StandardMemberCount, einsatzzeiten.Agt);
}
+ /// Whether is the CSA-Trupp the old rule recognised: trimmed,
+ /// ignoring case. Shared with the one-time #995 flag migration in ,
+ /// so that step compares the same way and adds no literal of its own.
+ public static bool IsChemical(string? name) => Matches(name?.Trim() ?? string.Empty, ChemicalName);
+
private static bool Matches(string trimmed, string legacyName) =>
string.Equals(trimmed, legacyName, StringComparison.OrdinalIgnoreCase);
}
@@ -1369,7 +1389,9 @@ private static IReadOnlyList ParseTruppTypes(JsonElement root)
RequiredName(x, "Trupp-Typ"),
TruppType.ClampMemberCount(Int(x, "memberCount", AtemschutzTrupp.StandardMemberCount)),
TruppType.ClampMaxDurationMinutes(
- Int(x, "maxDurationMinutes", AtemschutzTrupp.DefaultMaxDurationMinutes))));
+ Int(x, "maxDurationMinutes", AtemschutzTrupp.DefaultMaxDurationMinutes)),
+ x.TryGetProperty("namedByNumber", out var numbered) && numbered.ValueKind == JsonValueKind.True,
+ x.TryGetProperty("radiationMonitoring", out var radiation) && radiation.ValueKind == JsonValueKind.True));
}
return result;
@@ -1669,6 +1691,8 @@ public static string Serialize(MasterDataSet set)
name = t.Name,
memberCount = t.MemberCount,
maxDurationMinutes = t.MaxDurationMinutes,
+ namedByNumber = t.NamedByNumber,
+ radiationMonitoring = t.RadiationMonitoring,
}),
checklists = ChecklistsForExport(set),
navigation = NavigationForExport(set),
diff --git a/src/LageBuch.Persistence/MasterData/MasterDataStore.cs b/src/LageBuch.Persistence/MasterData/MasterDataStore.cs
index ae2b3b396..1d64655b0 100644
--- a/src/LageBuch.Persistence/MasterData/MasterDataStore.cs
+++ b/src/LageBuch.Persistence/MasterData/MasterDataStore.cs
@@ -23,6 +23,10 @@ public sealed class MasterDataStore
///
private const string TruppTypeDefaultsMigratedKey = "trupp_type_defaults_migrated";
+ /// Marks a store as having had its CSA-Trupp switched to "Funkrufname aus Nummer"
+ /// once (#995), so a brigade that switches it off again keeps it off.
+ private const string TruppTypeNamedByNumberMigratedKey = "trupp_type_named_by_number_migrated";
+
public static MasterDataSet GetOrCreate(string path)
{
using var cn = SqliteConnectionFactory.OpenReadWrite(path);
@@ -139,12 +143,14 @@ public static void Save(string path, MasterDataSet set)
Run(
cn,
tx,
- "INSERT INTO md_trupp_types (value, member_count, max_duration_minutes) VALUES ($v,$m,$d);",
+ "INSERT INTO md_trupp_types (value, member_count, max_duration_minutes, named_by_number, radiation_monitoring) VALUES ($v,$m,$d,$n,$r);",
p =>
{
p("$v", t.Name);
p("$m", t.MemberCount);
p("$d", t.MaxDurationMinutes);
+ p("$n", t.NamedByNumber ? 1 : 0);
+ p("$r", t.RadiationMonitoring ? 1 : 0);
});
}
@@ -419,7 +425,9 @@ is_visible INTEGER NOT NULL DEFAULT 1
CREATE TABLE IF NOT EXISTS md_trupp_types (
value TEXT NOT NULL,
member_count INTEGER NOT NULL DEFAULT 2,
- max_duration_minutes INTEGER NOT NULL DEFAULT 30
+ max_duration_minutes INTEGER NOT NULL DEFAULT 30,
+ named_by_number INTEGER NOT NULL DEFAULT 0,
+ radiation_monitoring INTEGER NOT NULL DEFAULT 0
);
CREATE TABLE IF NOT EXISTS md_personnel (
last_name TEXT NOT NULL,
@@ -536,6 +544,15 @@ apartment_labels TEXT NOT NULL DEFAULT '{}'
SchemaHelpers.AddColumnIfMissing(cn, null, "md_trupp_types", "max_duration_minutes", "INTEGER NOT NULL DEFAULT 30");
MigrateTruppTypeDefaults(cn);
+ // "Funkrufname aus Nummer" (#995). The DEFAULT leaves every row named by Funkrufname; the
+ // one-time step switches the CSA-Trupp over, since that is the type the request is about.
+ SchemaHelpers.AddColumnIfMissing(cn, null, "md_trupp_types", "named_by_number", "INTEGER NOT NULL DEFAULT 0");
+ MigrateTruppTypeNamedByNumber(cn);
+
+ // Strahlenschutzüberwachung (#994). No one-time step: no Trupp-Typ was under it before, and
+ // which one is, is the brigade's to tick.
+ SchemaHelpers.AddColumnIfMissing(cn, null, "md_trupp_types", "radiation_monitoring", "INTEGER NOT NULL DEFAULT 0");
+
// Widen a pre-#470 md_roles, where a Funktion was a bare name and nothing said how often it
// could be held. Unlike the Trupp-Typen above there is deliberately NO one-time marker: those
// rows needed MigrateTruppTypeDefaults because the old string rule gave two of them values
@@ -646,6 +663,45 @@ UPDATE md_trupp_types
}
}
+ ///
+ /// Switches an existing CSA-Trupp to "Funkrufname aus Nummer" once (#995), so a brigade sees
+ /// "CSA-Trupp 1" without having to find the setting. Gated on a marker like
+ /// , and marked on a fresh store too: a CSA-Trupp added
+ /// by hand later, or the flag switched off again, is the brigade's decision and stays.
+ ///
+ /// The name is compared in C# through , so this
+ /// step matches exactly what the #398 migration matched and adds no literal of its own.
+ ///
+ ///
+ private static void MigrateTruppTypeNamedByNumber(SqliteConnection cn)
+ {
+ if (ReadSetting(cn, TruppTypeNamedByNumberMigratedKey) is not null)
+ {
+ return;
+ }
+
+ var names = new List();
+ using (var select = cn.CreateCommand())
+ {
+ select.CommandText = "SELECT value FROM md_trupp_types;";
+ using var r = select.ExecuteReader();
+ while (r.Read())
+ {
+ names.Add(r.GetString(0));
+ }
+ }
+
+ foreach (var name in names.Where(LegacyTruppTypeDefaults.IsChemical))
+ {
+ using var update = cn.CreateCommand();
+ update.CommandText = "UPDATE md_trupp_types SET named_by_number = 1 WHERE value = $v;";
+ update.Parameters.AddWithValue("$v", name);
+ update.ExecuteNonQuery();
+ }
+
+ WriteSetting(cn, TruppTypeNamedByNumberMigratedKey, 1);
+ }
+
///
/// The three retired per-name Einsatzzeit settings as this store still holds them, falling back
/// per key to what IncidentSettings used to default to. Only the one-time Trupp-Typ
@@ -991,7 +1047,7 @@ private static List ReadDevices(SqliteConnection cn)
private static List ReadTruppTypes(SqliteConnection cn)
{
using var cmd = cn.CreateCommand();
- cmd.CommandText = "SELECT value, member_count, max_duration_minutes FROM md_trupp_types;";
+ cmd.CommandText = "SELECT value, member_count, max_duration_minutes, named_by_number, radiation_monitoring FROM md_trupp_types;";
using var r = cmd.ExecuteReader();
var list = new List();
while (r.Read())
@@ -1002,7 +1058,9 @@ private static List ReadTruppTypes(SqliteConnection cn)
list.Add(new TruppType(
r.GetString(0),
TruppType.ClampMemberCount(r.GetInt32(1)),
- TruppType.ClampMaxDurationMinutes(r.GetInt32(2))));
+ TruppType.ClampMaxDurationMinutes(r.GetInt32(2)),
+ r.GetInt32(3) != 0,
+ r.GetInt32(4) != 0));
}
return list;
diff --git a/src/LageBuch.Persistence/Sqlite/Migrations.cs b/src/LageBuch.Persistence/Sqlite/Migrations.cs
index b7e4000be..96b0bd62e 100644
--- a/src/LageBuch.Persistence/Sqlite/Migrations.cs
+++ b/src/LageBuch.Persistence/Sqlite/Migrations.cs
@@ -8,7 +8,7 @@ namespace LageBuch.Persistence.Sqlite;
public static class Migrations
{
- public const int CurrentVersion = 45;
+ public const int CurrentVersion = 46;
public static int GetVersion(SqliteConnection cn)
{
@@ -310,6 +310,11 @@ public static void Migrate(SqliteConnection cn)
ApplyV45(cn, tx);
}
+ if (version < 46)
+ {
+ ApplyV46(cn, tx);
+ }
+
// The version gate above is not proof that the steps it skipped ever ran: a build from a
// parallel branch numbers its own migrations too, so a file can carry a marker this lineage
// never put there and be missing a column no `version < N` will ever add back. Reconcile the
@@ -1364,6 +1369,27 @@ private static void ApplyV45(SqliteConnection cn, SqliteTransaction tx)
// Stryker restore all
}
+ // The Strahlenschutzüberwachung of a Strahlenschutztrupp (#994): a flag on the Trupp, and per
+ // crew member the dosimeter, Maske and PA numbers and the Alarmdosimeter's Ablesewert. Additive:
+ // an older file reads back with no Trupp under it. has_radiation marks a member who carries a
+ // record at all, so an empty record and none at all stay apart.
+ // Stryker disable all : SchemaGuard.Reconcile adds these same columns on every open (see V26).
+ private static void ApplyV46(SqliteConnection cn, SqliteTransaction tx)
+ {
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupps", "radiation_monitoring", "INTEGER NOT NULL DEFAULT 0");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "has_radiation", "INTEGER NOT NULL DEFAULT 0");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "osl_number", "TEXT");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "osl_missing", "INTEGER NOT NULL DEFAULT 0");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "alarm_number", "TEXT");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "alarm_missing", "INTEGER NOT NULL DEFAULT 0");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "mask_number", "TEXT");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "pa_number", "TEXT");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "dose_value", "TEXT");
+ SchemaHelpers.AddColumnIfMissing(cn, tx, "scba_trupp_members", "dose_unit", "INTEGER");
+
+ // Stryker restore all
+ }
+
[SuppressMessage(
"Security",
"CA2100",
diff --git a/src/LageBuch.Persistence/Sqlite/SchemaGuard.cs b/src/LageBuch.Persistence/Sqlite/SchemaGuard.cs
index d86164622..12938d90a 100644
--- a/src/LageBuch.Persistence/Sqlite/SchemaGuard.cs
+++ b/src/LageBuch.Persistence/Sqlite/SchemaGuard.cs
@@ -168,6 +168,16 @@ internal static class SchemaGuard
new("scba_trupps", "withdraw_time", "TEXT", false, null),
new("scba_trupps", "exit_time", "TEXT", false, null),
new("scba_trupps", "safety_trupp_id", "TEXT", false, null),
+ new("scba_trupps", "radiation_monitoring", "INTEGER", true, "0"),
+ new("scba_trupp_members", "has_radiation", "INTEGER", true, "0"),
+ new("scba_trupp_members", "osl_number", "TEXT", false, null),
+ new("scba_trupp_members", "osl_missing", "INTEGER", true, "0"),
+ new("scba_trupp_members", "alarm_number", "TEXT", false, null),
+ new("scba_trupp_members", "alarm_missing", "INTEGER", true, "0"),
+ new("scba_trupp_members", "mask_number", "TEXT", false, null),
+ new("scba_trupp_members", "pa_number", "TEXT", false, null),
+ new("scba_trupp_members", "dose_value", "TEXT", false, null),
+ new("scba_trupp_members", "dose_unit", "INTEGER", false, null),
new("situation_reports", "number", "INTEGER", false, null),
new("situation_reports", "reporter", "TEXT", false, null),
new("situation_reports", "location", "TEXT", false, null),
diff --git a/src/LageBuch.Sync/CommandApplier.cs b/src/LageBuch.Sync/CommandApplier.cs
index 017a19e38..82df68faf 100644
--- a/src/LageBuch.Sync/CommandApplier.cs
+++ b/src/LageBuch.Sync/CommandApplier.cs
@@ -181,14 +181,15 @@ public static class CommandApplier
incident.AddScbaTrupp(
clock,
c.Designation,
- c.Members.Select(m => new TruppMember(m.Role, m.Name)),
+ c.Members.Select(m => new TruppMember(m.Role, m.Name, m.Radiation?.ToRecord())),
c.EntryPressure,
c.TruppNumber,
c.CallSign,
c.Task,
c.MaxDurationMinutes,
c.ReturnPressureBar,
- c.PressureControlIntervalMinutes);
+ c.PressureControlIntervalMinutes,
+ c.RadiationMonitoring);
break;
case StartScbaTruppCommand c:
incident.StartScbaTrupp(clock, c.TruppId);
@@ -208,6 +209,9 @@ public static class CommandApplier
case ChangeScbaTruppTypeCommand c:
incident.ChangeScbaTruppType(c.TruppId, c.Designation, c.MaxDurationMinutes, c.PressureControlIntervalMinutes);
break;
+ case RecordScbaRadiationCommand c:
+ incident.RecordScbaRadiation(c.TruppId, c.Role, c.Record.ToRecord());
+ break;
case SetIncidentNumberCommand c:
incident.SetIncidentNumber(c.IncidentNumber is { } n ? new IncidentNumber(n) : null);
break;
diff --git a/src/LageBuch.Sync/IIncidentSession.cs b/src/LageBuch.Sync/IIncidentSession.cs
index 751c666f0..8e31a0bb3 100644
--- a/src/LageBuch.Sync/IIncidentSession.cs
+++ b/src/LageBuch.Sync/IIncidentSession.cs
@@ -258,7 +258,8 @@ void AddScbaTrupp(
string? task = null,
int maxDurationMinutes = AtemschutzTrupp.DefaultMaxDurationMinutes,
int returnPressureBar = AtemschutzTrupp.DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes);
+ int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false);
void StartScbaTrupp(Guid truppId);
@@ -276,6 +277,10 @@ void AddScbaTrupp(
/// apply only while the Trupp still waits.
void ChangeScbaTruppType(Guid truppId, string designation, int maxDurationMinutes, int pressureControlIntervalMinutes);
+ /// Records one crew member's Strahlenschutzüberwachung (#994): numbers, the
+ /// Alarmdosimeter's Ablesewert, or a dosimeter declared missing.
+ void RecordScbaRadiation(Guid truppId, TruppRole role, RadiationRecord record);
+
void SetIncidentNumber(IncidentNumber? number);
void SetKeyword(string? keyword);
diff --git a/src/LageBuch.Sync/IncidentSnapshot.cs b/src/LageBuch.Sync/IncidentSnapshot.cs
index 53cb41df5..b47cadcc4 100644
--- a/src/LageBuch.Sync/IncidentSnapshot.cs
+++ b/src/LageBuch.Sync/IncidentSnapshot.cs
@@ -177,7 +177,70 @@ public sealed record ForceUnitStrengthEditDto(
DateTimeOffset EditedAt,
int PreviousZugfuehrerCount = 0);
-public sealed record TruppMemberDto(TruppRole Role, string Name);
+/// A crew member. is their Strahlenschutzüberwachung (#994),
+/// absent for a Trupp not under it and for a peer that predates it.
+public sealed record TruppMemberDto(TruppRole Role, string Name, RadiationRecordDto? Radiation = null);
+
+///
+/// A crew member's Strahlenschutzüberwachung on the wire (#994). The Ablesewert travels as value
+/// and unit; both or neither. A host's snapshot is read leniently through
+/// ; a client's command goes through
+/// , which refuses what the domain refuses.
+///
+public sealed record RadiationRecordDto(
+ string? OslDosimeterNumber,
+ bool OslDosimeterMissing,
+ string? AlarmDosimeterNumber,
+ bool AlarmDosimeterMissing,
+ string? MaskNumber,
+ string? PaNumber,
+ decimal? DoseValue = null,
+ DoseUnit? DoseUnit = null)
+{
+ public static RadiationRecordDto From(RadiationRecord record)
+ {
+ ArgumentNullException.ThrowIfNull(record);
+ return new(
+ record.OslDosimeterNumber,
+ record.OslDosimeterMissing,
+ record.AlarmDosimeterNumber,
+ record.AlarmDosimeterMissing,
+ record.MaskNumber,
+ record.PaNumber,
+ record.AlarmReading?.Value,
+ record.AlarmReading?.Unit);
+ }
+
+ /// The checked record, for a command. Throws ArgumentException on anything the
+ /// domain refuses, or a value without a unit.
+ public RadiationRecord ToRecord()
+ {
+ if (DoseValue.HasValue != DoseUnit.HasValue)
+ {
+ throw new ArgumentException("Ein Ablesewert braucht Wert und Einheit.");
+ }
+
+ return new RadiationRecord(
+ OslDosimeterNumber,
+ OslDosimeterMissing,
+ AlarmDosimeterNumber,
+ AlarmDosimeterMissing,
+ MaskNumber,
+ PaNumber,
+ DoseValue is { } v && DoseUnit is { } u ? new DoseReading(v, u) : null);
+ }
+
+ /// The record from a host's snapshot, built leniently.
+ public RadiationRecord ToUntrustedRecord() => RadiationRecord.FromUntrusted(
+ OslDosimeterNumber,
+ OslDosimeterMissing,
+ AlarmDosimeterNumber,
+ AlarmDosimeterMissing,
+ MaskNumber,
+ PaNumber,
+ DoseValue,
+ (int?)DoseUnit);
+}
public sealed record PressureReadingDto(DateTimeOffset Time, int Bar, string? Location = null);
@@ -197,7 +260,8 @@ public sealed record ScbaTruppDto(
int PressureControlIntervalMinutes,
DateTimeOffset? ExitTime,
IReadOnlyList Readings,
- Guid? SafetyTruppId = null);
+ Guid? SafetyTruppId = null,
+ bool RadiationMonitoring = false);
public sealed record AuditEventDto(DateTimeOffset At, string Action, string By);
diff --git a/src/LageBuch.Sync/RemoteIncidentSession.cs b/src/LageBuch.Sync/RemoteIncidentSession.cs
index 77b278c2a..15e3e8119 100644
--- a/src/LageBuch.Sync/RemoteIncidentSession.cs
+++ b/src/LageBuch.Sync/RemoteIncidentSession.cs
@@ -645,17 +645,20 @@ public void AddScbaTrupp(
string? task = null,
int maxDurationMinutes = AtemschutzTrupp.DefaultMaxDurationMinutes,
int returnPressureBar = AtemschutzTrupp.DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes) =>
+ int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false) =>
Send(new AddScbaTruppCommand(
designation,
- members.Select(m => new TruppMemberDto(m.Role, m.Name)).ToList(),
+ members.Select(m => new TruppMemberDto(
+ m.Role, m.Name, m.Radiation is { } r ? RadiationRecordDto.From(r) : null)).ToList(),
callSign,
task,
maxDurationMinutes,
returnPressureBar,
pressureControlIntervalMinutes,
entryPressure,
- truppNumber));
+ truppNumber,
+ radiationMonitoring));
public void StartScbaTrupp(Guid truppId) => Send(new StartScbaTruppCommand(truppId));
@@ -672,6 +675,12 @@ public void SetScbaSafetyTrupp(Guid truppId, Guid? safetyTruppId) =>
public void ChangeScbaTruppType(Guid truppId, string designation, int maxDurationMinutes, int pressureControlIntervalMinutes) =>
Send(new ChangeScbaTruppTypeCommand(truppId, designation, maxDurationMinutes, pressureControlIntervalMinutes));
+ public void RecordScbaRadiation(Guid truppId, TruppRole role, RadiationRecord record)
+ {
+ ArgumentNullException.ThrowIfNull(record);
+ Send(new RecordScbaRadiationCommand(truppId, role, RadiationRecordDto.From(record)));
+ }
+
public void SetIncidentNumber(IncidentNumber? number) => Send(new SetIncidentNumberCommand(number?.Value));
public void SetKeyword(string? keyword) => Send(new SetKeywordCommand(keyword));
diff --git a/src/LageBuch.Sync/SnapshotMapper.cs b/src/LageBuch.Sync/SnapshotMapper.cs
index d8fc2506c..f936e895a 100644
--- a/src/LageBuch.Sync/SnapshotMapper.cs
+++ b/src/LageBuch.Sync/SnapshotMapper.cs
@@ -308,7 +308,8 @@ public static Incident FromSnapshot(IncidentSnapshot snapshot)
t.StartTime,
t.WithdrawTime,
t.Designation,
- t.Members.Select(m => new TruppMemberDto(m.Role, m.Name)).ToList(),
+ t.Members.Select(m => new TruppMemberDto(
+ m.Role, m.Name, m.Radiation is { } r ? RadiationRecordDto.From(r) : null)).ToList(),
t.CallSign,
t.Task,
t.EntryPressure,
@@ -317,7 +318,8 @@ public static Incident FromSnapshot(IncidentSnapshot snapshot)
t.PressureControlIntervalMinutes,
t.ExitTime,
t.PressureReadings.Select(p => new PressureReadingDto(p.Time, p.Bar, p.Location)).ToList(),
- t.SafetyTruppId);
+ t.SafetyTruppId,
+ t.RadiationMonitoring);
private static AtemschutzTrupp FromDto(ScbaTruppDto d) => AtemschutzTrupp.Rehydrate(
d.Id,
@@ -326,7 +328,7 @@ private static AtemschutzTrupp FromDto(ScbaTruppDto d) => AtemschutzTrupp.Rehydr
d.StartTime,
d.WithdrawTime,
d.Designation,
- d.Members.Select(m => new TruppMember(m.Role, m.Name)),
+ d.Members.Select(m => new TruppMember(m.Role, m.Name, m.Radiation?.ToUntrustedRecord())),
d.CallSign,
d.Task,
d.EntryPressure,
@@ -335,5 +337,6 @@ private static AtemschutzTrupp FromDto(ScbaTruppDto d) => AtemschutzTrupp.Rehydr
d.PressureControlIntervalMinutes,
d.ExitTime,
d.Readings.Select(p => new PressureReading(p.Time, p.Bar, p.Location)),
- d.SafetyTruppId);
+ d.SafetyTruppId,
+ d.RadiationMonitoring);
}
diff --git a/src/LageBuch.Sync/SyncCommand.cs b/src/LageBuch.Sync/SyncCommand.cs
index e03ff4cf8..ccbda92ac 100644
--- a/src/LageBuch.Sync/SyncCommand.cs
+++ b/src/LageBuch.Sync/SyncCommand.cs
@@ -1,4 +1,5 @@
using System.Text.Json.Serialization;
+using LageBuch.Domain.Atemschutz;
using LageBuch.Domain.CoMeasurement;
using LageBuch.Domain.Etb;
using LageBuch.Domain.Leadership;
@@ -51,6 +52,7 @@ namespace LageBuch.Sync;
[JsonDerivedType(typeof(MarkScbaRemovedCommand), "markScbaRemoved")]
[JsonDerivedType(typeof(SetScbaSafetyTruppCommand), "setScbaSafetyTrupp")]
[JsonDerivedType(typeof(ChangeScbaTruppTypeCommand), "changeScbaTruppType")]
+[JsonDerivedType(typeof(RecordScbaRadiationCommand), "recordScbaRadiation")]
[JsonDerivedType(typeof(SetIncidentNumberCommand), "setIncidentNumber")]
[JsonDerivedType(typeof(SetKeywordCommand), "setKeyword")]
[JsonDerivedType(typeof(SetAddressCommand), "setAddress")]
@@ -236,7 +238,7 @@ public sealed record RemoveForceUnitCommand(
public sealed record AddScbaTruppCommand(
string Designation, IReadOnlyList Members, string? CallSign, string? Task,
int MaxDurationMinutes, int ReturnPressureBar, int PressureControlIntervalMinutes,
- int EntryPressure, int? TruppNumber = null) : SyncCommand;
+ int EntryPressure, int? TruppNumber = null, bool RadiationMonitoring = false) : SyncCommand;
public sealed record StartScbaTruppCommand(Guid TruppId) : SyncCommand;
@@ -260,6 +262,11 @@ public sealed record SetScbaSafetyTruppCommand(Guid TruppId, Guid? SafetyTruppId
public sealed record ChangeScbaTruppTypeCommand(
Guid TruppId, string Designation, int MaxDurationMinutes, int PressureControlIntervalMinutes) : SyncCommand;
+/// Records one crew member's Strahlenschutzüberwachung (#994): numbers, Ablesewert or a
+/// dosimeter declared missing. Carries no operator: the ETB line is written by the sending device,
+/// like every other Atemschutz mutation.
+public sealed record RecordScbaRadiationCommand(Guid TruppId, TruppRole Role, RadiationRecordDto Record) : SyncCommand;
+
public sealed record SetIncidentNumberCommand(string? IncidentNumber) : SyncCommand;
public sealed record SetKeywordCommand(string? Keyword) : SyncCommand;
diff --git a/src/LageBuch.Sync/SyncProtocol.cs b/src/LageBuch.Sync/SyncProtocol.cs
index 5535bfb72..d9b1232e3 100644
--- a/src/LageBuch.Sync/SyncProtocol.cs
+++ b/src/LageBuch.Sync/SyncProtocol.cs
@@ -249,15 +249,29 @@ public static class SyncProtocol
/// Fahrzeugtyp is filled from. A peer at 42 drops the key and reads none, which only leaves its
/// new vehicles to be typed by hand, so the floor stays at 40.
///
+ ///
+ /// 44: a Trupp-Typ in /masterdata may carry namedByNumber (#995), which makes the
+ /// Atemschutz form ask for a number and name the Trupp "CSA-Trupp 1". The resulting name travels
+ /// in the Funkrufname a Trupp already had, so no command changes. A peer at 43 drops the key
+ /// and offers its free Funkrufname box instead, so the floor stays at 40.
+ ///
+ ///
+ /// 45: the Strahlenschutzüberwachung of a Strahlenschutztrupp (#994). A client may send
+ /// recordScbaRadiation, which a host at 44 does not know, and addScbaTrupp carries
+ /// radiationMonitoring, which a host at 44 would drop -- registering the Trupp outside
+ /// the Überwachung and letting the Einsatz close without its Ablesewerte. The snapshot's Trupps
+ /// and members carry the same, and a Trupp-Typ in /masterdata an optional
+ /// radiationMonitoring. The floor rises to 45.
+ ///
///
- public const int ProtocolVersion = 43;
+ public const int ProtocolVersion = 45;
///
/// The oldest contract this build still speaks. A peer below it is refused with a message naming
/// which end to update; a peer at or above it is served. See for
/// when to raise this.
///
- public const int MinimumProtocolVersion = 40;
+ public const int MinimumProtocolVersion = 45;
///
/// What an absent or zero protocol number on the wire means: the contract as it stood at v0.6.1,
diff --git a/tests/Fixtures/stammdaten-vollstaendig.json b/tests/Fixtures/stammdaten-vollstaendig.json
index 0230ca6e5..672def74b 100644
--- a/tests/Fixtures/stammdaten-vollstaendig.json
+++ b/tests/Fixtures/stammdaten-vollstaendig.json
@@ -80,17 +80,23 @@
{
"name": "Angriffstrupp",
"memberCount": 2,
- "maxDurationMinutes": 30
+ "maxDurationMinutes": 30,
+ "namedByNumber": false,
+ "radiationMonitoring": false
},
{
"name": "CSA-Trupp",
"memberCount": 3,
- "maxDurationMinutes": 20
+ "maxDurationMinutes": 20,
+ "namedByNumber": true,
+ "radiationMonitoring": false
},
{
"name": "Langzeit-Trupp",
"memberCount": 2,
- "maxDurationMinutes": 240
+ "maxDurationMinutes": 240,
+ "namedByNumber": false,
+ "radiationMonitoring": true
}
],
"checklists": [
diff --git a/tests/LageBuch.Acceptance.Tests/MasterDataEditorRenderTests.cs b/tests/LageBuch.Acceptance.Tests/MasterDataEditorRenderTests.cs
index c9cfc3256..53784cebe 100644
--- a/tests/LageBuch.Acceptance.Tests/MasterDataEditorRenderTests.cs
+++ b/tests/LageBuch.Acceptance.Tests/MasterDataEditorRenderTests.cs
@@ -54,11 +54,11 @@ public MasterDataSet Get() => MasterDataSet.Empty with
{
new TruppType("Angriffstrupp"),
new TruppType("Wassertrupp"),
- new TruppType("CSA-Trupp", 3, 20),
+ new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true),
// Three people like the CSA-Trupp but the full 30 minutes (#418) -- the pair no
// rule keyed off a designation could ever have expressed.
- new TruppType("Strahlenschutztrupp", 3, 30),
+ new TruppType("Strahlenschutztrupp", 3, 30, RadiationMonitoring: true),
},
// Wachen and Funkrufnamen derive from these rows (plus the roster's "Land 1").
@@ -382,6 +382,20 @@ public void Trupp_typen_section_renders_staerke_and_einsatzzeit_per_row()
Assert.Contains(numbers, n => n.Value == 20);
Assert.Contains(numbers, n => n.Value == 30);
+ // #995: one "Funkrufname aus Nummer" box per row, ticked for the CSA-Trupp alone.
+ var numbered = view.GetVisualDescendants().OfType()
+ .Where(c => AutomationProperties.GetName(c) == "Funkrufname aus Nummer")
+ .ToList();
+ Assert.Equal(4, numbered.Count);
+ Assert.Equal(1, numbered.Count(c => c.IsChecked == true));
+
+ // #994: one "Strahlenschutz" box per row, ticked for the Strahlenschutztrupp alone.
+ var radiation = view.GetVisualDescendants().OfType()
+ .Where(c => AutomationProperties.GetName(c) == "Strahlenschutz")
+ .ToList();
+ Assert.Equal(4, radiation.Count);
+ Assert.Equal(1, radiation.Count(c => c.IsChecked == true));
+
var dir = Path.Join(Path.GetTempPath(), "lagebuch-shots");
Directory.CreateDirectory(dir);
using var frame = window.CaptureRenderedFrame()!;
diff --git a/tests/LageBuch.Acceptance.Tests/OverlayContractTests.cs b/tests/LageBuch.Acceptance.Tests/OverlayContractTests.cs
index cee57af5e..fd510fc90 100644
--- a/tests/LageBuch.Acceptance.Tests/OverlayContractTests.cs
+++ b/tests/LageBuch.Acceptance.Tests/OverlayContractTests.cs
@@ -12,6 +12,7 @@
using LageBuch.AppLogic.Services;
using LageBuch.AppLogic.ViewModels;
using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
using LageBuch.Domain.CoMeasurement;
using LageBuch.Domain.Tasks;
using LageBuch.Persistence.MasterData;
@@ -58,6 +59,7 @@ public class OverlayContractTests
new("Workspace.DispatchChannelDialog", typeof(IncidentWorkspaceViewModel), typeof(DispatchChannelDialogViewModel), OpenWorkspaceDispatchChannelDialog),
new("Workspace.LeadershipPersonDialog", typeof(IncidentWorkspaceViewModel), typeof(LeadershipPersonDialogViewModel), OpenWorkspaceLeadershipPersonDialog),
new("Workspace.RoleAssignmentDialog", typeof(IncidentWorkspaceViewModel), typeof(RoleAssignmentDialogViewModel), OpenWorkspaceRoleAssignmentDialog),
+ new("Workspace.RadiationDialog", typeof(IncidentWorkspaceViewModel), typeof(RadiationDialogViewModel), OpenWorkspaceRadiationDialog),
new("Main.OperatorPrompt", typeof(MainWindowViewModel), typeof(OperatorPromptViewModel), OpenMainOperatorPrompt),
new("Main.About", typeof(MainWindowViewModel), typeof(AboutViewModel), OpenMainAbout),
new("Main.ShortcutOverview", typeof(MainWindowViewModel), typeof(ShortcutOverviewViewModel), OpenMainShortcutOverview),
@@ -377,6 +379,25 @@ private static Opened OpenWorkspaceRoleAssignmentDialog()
return new(window, opener, ViewOf(window), () => vm.PendingRoleAssignmentDialog is null, () => vm.PendingRoleAssignmentDialog?.CancelCommand.Execute(null));
}
+ // #994: a Strahlenschutztrupp's own STRAHLENSCHUTZ button. Cancel leaves its records as they were.
+ private static Opened OpenWorkspaceRadiationDialog()
+ {
+ var (window, vm) = ShowWorkspace(s => s.AddScbaTrupp(
+ "Strahlenschutztrupp",
+ TruppMember.Crew(AnonymizedExampleData.OperatorSurname, AnonymizedExampleData.OperatorSurnameAlt, AnonymizedExampleData.PersonLastName),
+ 300,
+ radiationMonitoring: true));
+ WorkspaceRenderHelper.SelectTab(window, "ATEMSCHUTZ");
+ var opener = RowButton(window, "TruppGrid", b => b.Name == "RadiationButton");
+ Activate(opener);
+ return new(
+ window,
+ opener,
+ ViewOf(window),
+ () => vm.PendingRadiationDialog is null && vm.Scba.Trupps[0].RadiationHint == "Dosimeter-Nr. fehlen",
+ () => vm.PendingRadiationDialog?.CancelCommand.Execute(null));
+ }
+
// A row's own button, the way a keyboard user reaches it: Tab into the grid, then to the row.
private static Button RowButton(Window window, string grid, Func match) =>
Named(window, grid).GetVisualDescendants().OfType()
diff --git a/tests/LageBuch.Acceptance.Tests/RadiationDialogRenderTests.cs b/tests/LageBuch.Acceptance.Tests/RadiationDialogRenderTests.cs
new file mode 100644
index 000000000..adf2fb16c
--- /dev/null
+++ b/tests/LageBuch.Acceptance.Tests/RadiationDialogRenderTests.cs
@@ -0,0 +1,98 @@
+using Avalonia.Automation;
+using Avalonia.Controls;
+using Avalonia.Headless;
+using Avalonia.Headless.XUnit;
+using Avalonia.Threading;
+using Avalonia.VisualTree;
+using LageBuch.App.Shared.Views;
+using LageBuch.AppLogic.ViewModels;
+using LageBuch.Persistence.MasterData;
+
+namespace LageBuch.Acceptance.Tests;
+
+// #994: a Strahlenschutztrupp's row offers STRAHLENSCHUTZ and says what is still owed; the dialog
+// it opens has one block of fields per crew member and asks before a dosimeter is declared missing.
+public class RadiationDialogRenderTests
+{
+ private static (IncidentWorkspaceViewModel Vm, Window Window) Workspace()
+ {
+ var vm = WorkspaceRenderHelper.BuildEditableWorkspaceWithAllBars();
+ vm.Scba.NewDesignation = "Strahlenschutztrupp";
+ vm.Scba.NewCallSign = "HLF 1";
+ vm.Scba.NewTruppfuehrer = AnonymizedExampleData.OperatorSurname;
+ vm.Scba.NewTruppmann = AnonymizedExampleData.OperatorSurnameAlt;
+ vm.Scba.NewZweiterTruppmann = AnonymizedExampleData.PersonLastName;
+ vm.Scba.AddTruppCommand.Execute(null);
+
+ var window = new Window
+ {
+ Content = new IncidentWorkspaceView { DataContext = vm },
+ Width = 1920,
+ Height = 1032,
+ };
+ window.Show();
+ Dispatcher.UIThread.RunJobs();
+ WorkspaceRenderHelper.SelectTab(window, "ATEMSCHUTZ");
+ Dispatcher.UIThread.RunJobs();
+ return (vm, window);
+ }
+
+ [AvaloniaFact]
+ public void A_strahlenschutztrupp_row_offers_the_dialog_and_holds_im_einsatz_back()
+ {
+ var (vm, window) = Workspace();
+ var row = vm.Scba.Trupps[^1];
+
+ Assert.True(row.IsRadiationMonitored);
+ Assert.Equal("Dosimeter-Nr. fehlen", row.RadiationHint);
+ Assert.False(row.StartCommand.CanExecute(null));
+
+ var truppColumn = window.GetVisualDescendants().OfType().Single()
+ .Columns.Single(c => (string?)c.Header == "TRUPP");
+ var cell = truppColumn.GetCellContent(row)!;
+ var button = Assert.Single(cell.GetVisualDescendants().OfType(), b => b.Name == "RadiationButton");
+ Assert.True(button.IsVisible);
+ Assert.Contains(cell.GetVisualDescendants().OfType(), t => t.Name == "RadiationHintText" && t.IsVisible);
+
+ // The Angriffstrupp the helper registered has neither.
+ var ordinary = truppColumn.GetCellContent(vm.Scba.Trupps[0])!;
+ Assert.DoesNotContain(ordinary.GetVisualDescendants().OfType(), b => b.Name == "RadiationButton" && b.IsVisible);
+ window.Close();
+ }
+
+ [AvaloniaFact]
+ public void The_dialog_has_a_block_per_crew_member_and_asks_before_nicht_vorhanden()
+ {
+ var (vm, window) = Workspace();
+ vm.Scba.Trupps[^1].OpenRadiationCommand.Execute(null);
+ Dispatcher.UIThread.RunJobs();
+
+ var view = Assert.Single(window.GetVisualDescendants().OfType());
+ var dialog = Assert.IsType(vm.PendingRadiationDialog);
+ Assert.Equal(3, dialog.Members.Count);
+ Assert.Equal(
+ 3, view.GetVisualDescendants().OfType().Count(t => AutomationProperties.GetName(t) == "OSL-Dosimeter Nummer"));
+ Assert.Equal(3, view.GetVisualDescendants().OfType().Count(c => AutomationProperties.GetName(c) == "Einheit"));
+ Assert.All(
+ view.GetVisualDescendants().OfType().Where(c => AutomationProperties.GetName(c) == "Einheit"),
+ c => Assert.Equal("mSv", c.SelectedItem));
+
+ var panel = view.GetVisualDescendants().OfType().Single(b => b.Name == "MissingWarningPanel");
+ Assert.False(panel.IsVisible);
+
+ dialog.Members[1].DeclareAlarmMissingCommand.Execute(null);
+ Dispatcher.UIThread.RunJobs();
+
+ Assert.True(panel.IsVisible);
+
+ var dir = Environment.GetEnvironmentVariable("RENDER_OUT");
+ if (!string.IsNullOrWhiteSpace(dir))
+ {
+ Directory.CreateDirectory(dir);
+ using var frame = window.CaptureRenderedFrame()!;
+ frame.SavePng(Path.Join(dir, "strahlenschutz-dialog.png"));
+ }
+
+ window.Close();
+ }
+}
diff --git a/tests/LageBuch.Acceptance.Tests/WorkspaceRenderHelper.cs b/tests/LageBuch.Acceptance.Tests/WorkspaceRenderHelper.cs
index e542350eb..a642b94d6 100644
--- a/tests/LageBuch.Acceptance.Tests/WorkspaceRenderHelper.cs
+++ b/tests/LageBuch.Acceptance.Tests/WorkspaceRenderHelper.cs
@@ -31,7 +31,7 @@ private static MasterDataSet Md() => MasterDataSet.Empty with
new ChecklistTemplateItem("Kopfdaten ETB ausgefüllt (Einsatzort, Bearbeiter)?", false),
},
new[] { new ChecklistTemplateItem("Fahrzeug abgerüstet und einsatzbereit?", true) }),
- TruppTypes = new[] { new TruppType("Angriffstrupp"), new TruppType("Sicherheitstrupp"), new TruppType("CSA-Trupp", 3, 20) },
+ TruppTypes = new[] { new TruppType("Angriffstrupp"), new TruppType("Sicherheitstrupp"), new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true), new TruppType("Strahlenschutztrupp", 3, 30, RadiationMonitoring: true) },
UnitStatus = new[] { "Alarmiert", "Auf Anfahrt", "Bereitstellungsraum", "Im Einsatz" },
// Wachen and Funkrufnamen suggestions derive from the vehicles (and the roster below).
diff --git a/tests/LageBuch.AppLogic.Tests/CoMessprotokollViewModelTests.cs b/tests/LageBuch.AppLogic.Tests/CoMessprotokollViewModelTests.cs
index d693ecdb5..8a20b1762 100644
--- a/tests/LageBuch.AppLogic.Tests/CoMessprotokollViewModelTests.cs
+++ b/tests/LageBuch.AppLogic.Tests/CoMessprotokollViewModelTests.cs
@@ -1429,7 +1429,8 @@ public void AddScbaTrupp(
string? task = null,
int maxDurationMinutes = AtemschutzTrupp.DefaultMaxDurationMinutes,
int returnPressureBar = AtemschutzTrupp.DefaultReturnPressureBar,
- int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes) =>
+ int pressureControlIntervalMinutes = AtemschutzTrupp.DefaultPressureControlIntervalMinutes,
+ bool radiationMonitoring = false) =>
_inner.AddScbaTrupp(
designation,
members,
@@ -1439,7 +1440,8 @@ public void AddScbaTrupp(
task,
maxDurationMinutes,
returnPressureBar,
- pressureControlIntervalMinutes);
+ pressureControlIntervalMinutes,
+ radiationMonitoring);
public void StartScbaTrupp(Guid truppId) => _inner.StartScbaTrupp(truppId);
@@ -1455,6 +1457,9 @@ public void SetScbaSafetyTrupp(Guid truppId, Guid? safetyTruppId) =>
public void ChangeScbaTruppType(Guid truppId, string designation, int maxDurationMinutes, int pressureControlIntervalMinutes) =>
_inner.ChangeScbaTruppType(truppId, designation, maxDurationMinutes, pressureControlIntervalMinutes);
+ public void RecordScbaRadiation(Guid truppId, TruppRole role, RadiationRecord record) =>
+ _inner.RecordScbaRadiation(truppId, role, record);
+
public void SetIncidentNumber(IncidentNumber? number) => _inner.SetIncidentNumber(number);
public void SetKeyword(string? keyword) => _inner.SetKeyword(keyword);
diff --git a/tests/LageBuch.AppLogic.Tests/IncidentWorkspaceRadiationTests.cs b/tests/LageBuch.AppLogic.Tests/IncidentWorkspaceRadiationTests.cs
new file mode 100644
index 000000000..556db10b8
--- /dev/null
+++ b/tests/LageBuch.AppLogic.Tests/IncidentWorkspaceRadiationTests.cs
@@ -0,0 +1,102 @@
+using LageBuch.AppLogic.Services;
+using LageBuch.AppLogic.ViewModels;
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+using LageBuch.Persistence.MasterData;
+
+namespace LageBuch.AppLogic.Tests;
+
+/// The workspace's side of the Strahlenschutzüberwachung (#994): the dialog overlay and the
+/// refused close.
+public sealed class IncidentWorkspaceRadiationTests
+{
+ private static readonly DateTimeOffset T0 = new(2026, 9, 19, 22, 17, 0, TimeSpan.FromHours(2));
+
+ private static IncidentWorkspaceViewModel Workspace(out LocalIncidentSession session)
+ {
+ var clock = new FixedClock(T0);
+ session = TestSession.StartNew(
+ new FakeStore(),
+ clock,
+ new SessionOperator("Müller"),
+ "/x.lagebuch",
+ Array.Empty<(string, bool)>(),
+ Array.Empty<(string, bool)>());
+ return new IncidentWorkspaceViewModel(
+ session,
+ clock,
+ new FakeTicker(),
+ MasterDataSet.Empty with { TruppTypes = new[] { new TruppType("Strahlenschutztrupp", 2, 30, RadiationMonitoring: true) } },
+ new FakeDialogs(),
+ new FakeAlarmService(),
+ new NoopIncidentHostController());
+ }
+
+ private static AtemschutzTrupp StartedStrahlenschutztrupp(LocalIncidentSession session)
+ {
+ session.AddScbaTrupp("Strahlenschutztrupp", TruppMember.Crew("Maier", "Wagner"), 300, callSign: "HLF 1", radiationMonitoring: true);
+ var trupp = session.Incident.ScbaTrupps[^1];
+ foreach (var m in trupp.Members.ToList())
+ {
+ session.RecordScbaRadiation(trupp.Id, m.Role, new RadiationRecord(oslDosimeterNumber: "1", alarmDosimeterNumber: "2"));
+ }
+
+ session.StartScbaTrupp(trupp.Id);
+ return trupp;
+ }
+
+ [Fact]
+ public void The_row_opens_the_strahlenschutz_dialog_as_an_overlay()
+ {
+ using var vm = Workspace(out var session);
+ StartedStrahlenschutztrupp(session);
+ var row = Assert.Single(vm.Scba.Trupps);
+
+ row.OpenRadiationCommand.Execute(null);
+
+ var dialog = Assert.IsType(vm.PendingRadiationDialog);
+ Assert.Equal("Strahlenschutz · HLF 1 · Strahlenschutztrupp", dialog.Title);
+
+ dialog.CancelCommand.Execute(null);
+ Assert.Null(vm.PendingRadiationDialog);
+ }
+
+ // Refused rather than warned about: a closed Einsatz is read-only, so the reading could never
+ // be added afterwards. The way out leads to where it is entered.
+ [Fact]
+ public void Closing_with_a_missing_reading_is_refused_and_leads_to_the_atemschutzueberwachung()
+ {
+ using var vm = Workspace(out var session);
+ StartedStrahlenschutztrupp(session);
+
+ vm.CloseIncidentCommand.Execute(null);
+
+ var refusal = vm.PendingConfirm;
+ Assert.NotNull(refusal);
+ Assert.Equal("Einsatz noch nicht abschließbar", refusal.Title);
+ Assert.StartsWith("Ablesewerte fehlen: HLF 1 · Strahlenschutztrupp.", refusal.Message, StringComparison.Ordinal);
+ Assert.Equal("ZUR ATEMSCHUTZÜBERWACHUNG", refusal.ConfirmLabel);
+
+ refusal.ConfirmCommand.Execute(null);
+
+ Assert.Equal(IncidentState.Open, session.Incident.State);
+ Assert.Same(vm.Scba, vm.SelectedNavItem?.Content);
+ Assert.Null(vm.PendingConfirm);
+ }
+
+ [Fact]
+ public void Once_every_reading_is_in_the_einsatz_closes_as_usual()
+ {
+ using var vm = Workspace(out var session);
+ var trupp = StartedStrahlenschutztrupp(session);
+ foreach (var m in trupp.Members.ToList())
+ {
+ session.RecordScbaRadiation(
+ trupp.Id, m.Role, new RadiationRecord("1", false, "2", false, alarmReading: new DoseReading(0.01m, DoseUnit.MilliSievert)));
+ }
+
+ vm.CloseIncidentCommand.Execute(null);
+
+ Assert.Equal("Einsatz abschließen?", vm.PendingConfirm?.Title);
+ }
+}
diff --git a/tests/LageBuch.AppLogic.Tests/MasterDataSectionTests.cs b/tests/LageBuch.AppLogic.Tests/MasterDataSectionTests.cs
index 1c68e35cd..bcaf535f2 100644
--- a/tests/LageBuch.AppLogic.Tests/MasterDataSectionTests.cs
+++ b/tests/LageBuch.AppLogic.Tests/MasterDataSectionTests.cs
@@ -462,6 +462,42 @@ public void TruppTypes_ToValues_clamps_an_einsatzzeit_no_countdown_can_run()
Assert.Equal(1, s.ToValues()[0].MaxDurationMinutes);
}
+ // #995: the "Funkrufname aus Nummer" box survives the editor in both directions.
+ [Fact]
+ public void TruppTypes_numbering_flag_round_trips_and_flags_a_change()
+ {
+ var changes = 0;
+ var s = new TruppTypesSection(
+ "Trupp-Typen",
+ new[] { new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true), new TruppType("Angriffstrupp") },
+ () => changes++);
+
+ Assert.True(s.Rows[0].NamedByNumber);
+ Assert.False(s.Rows[1].NamedByNumber);
+
+ s.Rows[1].NamedByNumber = true;
+
+ Assert.Equal(1, changes);
+ Assert.Equal(new[] { true, true }, s.ToValues().Select(t => t.NamedByNumber));
+ }
+
+ // #994: the "Strahlenschutz" box survives the editor in both directions.
+ [Fact]
+ public void TruppTypes_strahlenschutz_flag_round_trips_and_flags_a_change()
+ {
+ var changes = 0;
+ var s = new TruppTypesSection(
+ "Trupp-Typen",
+ new[] { new TruppType("Strahlenschutztrupp", 3, 30, RadiationMonitoring: true), new TruppType("Angriffstrupp") },
+ () => changes++);
+
+ Assert.True(s.Rows[0].RadiationMonitoring);
+ s.Rows[1].RadiationMonitoring = true;
+
+ Assert.Equal(1, changes);
+ Assert.Equal(new[] { true, true }, s.ToValues().Select(t => t.RadiationMonitoring));
+ }
+
[Fact]
public void TruppTypes_editing_a_row_flags_a_change()
{
diff --git a/tests/LageBuch.AppLogic.Tests/ScbaNumberedTruppTests.cs b/tests/LageBuch.AppLogic.Tests/ScbaNumberedTruppTests.cs
new file mode 100644
index 000000000..b10995066
--- /dev/null
+++ b/tests/LageBuch.AppLogic.Tests/ScbaNumberedTruppTests.cs
@@ -0,0 +1,262 @@
+using LageBuch.AppLogic.ViewModels;
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+using LageBuch.Persistence.MasterData;
+
+namespace LageBuch.AppLogic.Tests;
+
+///
+/// A Trupp-Typ marked "Funkrufname aus Nummer" (#995): the form asks for a number instead of a
+/// Funkrufname and the Trupp is called "CSA-Trupp 1" -- in the grid, the banners and the ETB.
+///
+public class ScbaNumberedTruppTests
+{
+ private const string CsaTrupp = "CSA-Trupp";
+
+ private static readonly DateTimeOffset T0 = new(2026, 6, 22, 9, 0, 0, TimeSpan.FromHours(2));
+
+ private static MasterDataSet Md() => MasterDataSet.Empty with
+ {
+ TruppTypes = new[] { new TruppType("Angriffstrupp"), new TruppType(CsaTrupp, 3, 20, NamedByNumber: true) },
+ };
+
+ private static LocalIncidentSession NewSession(FixedClock clock) =>
+ TestSession.StartNew(
+ new FakeStore(),
+ clock,
+ new SessionOperator("Müller", "FFB 12/1"),
+ "/x.lagebuch",
+ Array.Empty<(string, bool)>(),
+ Array.Empty<(string, bool)>());
+
+ private static ScbaViewModel Vm(FixedClock clock, LocalIncidentSession session) =>
+ new(session, Md(), clock, new FakeTicker(), new FakeAlarmService(), () => { });
+
+ private static void FillCrew(ScbaViewModel vm)
+ {
+ vm.NewTruppfuehrer = "Müller";
+ vm.NewTruppmann = "Schmidt";
+ vm.NewZweiterTruppmann = "Huber";
+ }
+
+ [Fact]
+ public void Numbered_trupp_art_hides_the_call_sign_and_suggests_number_one()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+
+ vm.NewDesignation = "Angriffstrupp";
+ Assert.False(vm.IsNamedByNumber);
+
+ vm.NewDesignation = CsaTrupp;
+ Assert.True(vm.IsNamedByNumber);
+ Assert.Equal(1, vm.NewTypeNumber);
+ }
+
+ [Fact]
+ public void Registered_numbered_trupp_is_called_csa_trupp_1_in_grid_and_etb()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ using var vm = Vm(clock, session);
+
+ vm.NewDesignation = CsaTrupp;
+ FillCrew(vm);
+
+ // A Funkrufname typed before the Trupp-Art was switched is not what the Trupp is called.
+ vm.NewCallSign = "HLF 1";
+ vm.AddTruppCommand.Execute(null);
+
+ var row = Assert.Single(vm.Trupps);
+ Assert.Equal("CSA-Trupp 1", row.DisplayName);
+ Assert.Equal("CSA-Trupp 1", row.CallSign);
+ var entry = Assert.Single(
+ session.Incident.Journal,
+ e => e.Text == "CSA-Trupp 1 bereitgestellt: Müller / Schmidt / Huber, Einstiegsdruck 300 bar");
+ Assert.Equal("CSA-Trupp 1", entry.From);
+ }
+
+ // Counted per Trupp-Art: the Angriffstrupp before it does not make this "CSA-Trupp 2".
+ [Fact]
+ public void Second_csa_trupp_is_suggested_number_two()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = "Angriffstrupp";
+ vm.NewTruppfuehrer = "Maier";
+ vm.NewTruppmann = "Wagner";
+ vm.AddTruppCommand.Execute(null);
+
+ vm.NewDesignation = CsaTrupp;
+ Assert.Equal(1, vm.NewTypeNumber);
+ FillCrew(vm);
+ vm.AddTruppCommand.Execute(null);
+
+ vm.NewDesignation = CsaTrupp;
+ Assert.Equal(2, vm.NewTypeNumber);
+ }
+
+ [Fact]
+ public void A_number_set_by_hand_names_the_trupp()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+
+ vm.NewDesignation = CsaTrupp;
+ vm.NewTypeNumber = 5;
+ FillCrew(vm);
+ vm.AddTruppCommand.Execute(null);
+
+ Assert.Equal("CSA-Trupp 5", Assert.Single(vm.Trupps).DisplayName);
+ }
+
+ [Fact]
+ public void Number_already_in_use_is_refused_with_a_message()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = CsaTrupp;
+ FillCrew(vm);
+ vm.AddTruppCommand.Execute(null);
+
+ vm.NewDesignation = CsaTrupp;
+ vm.NewTypeNumber = 1;
+ FillCrew(vm);
+ vm.AddTruppCommand.Execute(null);
+
+ Assert.Single(vm.Trupps);
+ Assert.Equal(ValidationMessages.TypeNumberInUse, vm.NewTypeNumberError);
+ Assert.Contains(ValidationMessages.TypeNumberInUse, vm.ErrorSummary, StringComparison.Ordinal);
+ }
+
+ [Fact]
+ public void Number_is_required()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = CsaTrupp;
+ vm.NewTypeNumber = 0;
+ FillCrew(vm);
+ vm.AddTruppCommand.Execute(null);
+
+ Assert.Empty(vm.Trupps);
+ Assert.Equal(ValidationMessages.Required, vm.NewTypeNumberError);
+ }
+
+ // A Trupp registered elsewhere -- a joined client, or the host while this form sits open --
+ // moves the suggestion on, as long as nobody typed a number of their own.
+ [Fact]
+ public void A_trupp_registered_meanwhile_moves_the_suggestion_on()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ using var vm = Vm(clock, session);
+ vm.NewDesignation = CsaTrupp;
+ Assert.Equal(1, vm.NewTypeNumber);
+
+ session.AddScbaTrupp(
+ CsaTrupp,
+ TruppMember.Crew("Maier", "Wagner", "Fischer"),
+ entryPressure: 300,
+ callSign: AtemschutzTrupp.NumberedCallSign(CsaTrupp, 1));
+
+ Assert.Equal(2, vm.NewTypeNumber);
+ }
+
+ // A number somebody typed is theirs: a Trupp registered elsewhere does not overwrite it. The
+ // press tells them if it was taken meanwhile.
+ [Fact]
+ public void A_number_typed_by_hand_survives_a_trupp_registered_meanwhile()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ using var vm = Vm(clock, session);
+ vm.NewDesignation = CsaTrupp;
+ vm.NewTypeNumber = 5;
+
+ RegisterElsewhere(session, 1);
+
+ Assert.Equal(5, vm.NewTypeNumber);
+ }
+
+ // The suggestion itself is not "typed by hand": once moved on, it keeps moving.
+ [Fact]
+ public void A_suggestion_that_moved_on_keeps_moving()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ RegisterElsewhere(session, 1);
+ using var vm = Vm(clock, session);
+ vm.NewDesignation = CsaTrupp;
+ Assert.Equal(2, vm.NewTypeNumber);
+
+ RegisterElsewhere(session, 2);
+
+ Assert.Equal(3, vm.NewTypeNumber);
+ }
+
+ // Another Trupp-Art counts its own numbers, so a number typed for one is forgotten on switching.
+ [Fact]
+ public void Switching_the_trupp_art_forgets_a_typed_number()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ using var vm = Vm(clock, session);
+ vm.NewDesignation = CsaTrupp;
+ vm.NewTypeNumber = 5;
+ vm.NewDesignation = "Angriffstrupp";
+ vm.NewDesignation = CsaTrupp;
+ Assert.Equal(1, vm.NewTypeNumber);
+
+ RegisterElsewhere(session, 1);
+
+ Assert.Equal(2, vm.NewTypeNumber);
+ }
+
+ [Fact]
+ public void Pressing_announces_the_number_error()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = CsaTrupp;
+ var raised = new List();
+ vm.PropertyChanged += (_, e) => raised.Add(e.PropertyName);
+
+ vm.AddTruppCommand.Execute(null);
+
+ Assert.Contains(nameof(ScbaViewModel.NewTypeNumberError), raised);
+ }
+
+ private static void RegisterElsewhere(LocalIncidentSession session, int number) =>
+ session.AddScbaTrupp(
+ CsaTrupp,
+ TruppMember.Crew("Maier", "Wagner", "Fischer"),
+ entryPressure: 300,
+ callSign: AtemschutzTrupp.NumberedCallSign(CsaTrupp, number));
+
+ // The TRUPP-ART ComboBox writes null through its binding when the form resets, whatever the
+ // property's declared type -- the number suggestion must not throw on it mid-Einsatz.
+ [Fact]
+ public void A_cleared_trupp_art_selection_does_not_throw()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = CsaTrupp;
+
+ typeof(ScbaViewModel).GetProperty(nameof(ScbaViewModel.NewDesignation))?.SetValue(vm, null);
+
+ Assert.False(vm.IsNamedByNumber);
+ }
+
+ [Fact]
+ public void An_ordinary_trupp_art_shows_no_number_error()
+ {
+ var clock = new FixedClock(T0);
+ using var vm = Vm(clock, NewSession(clock));
+ vm.NewDesignation = "Angriffstrupp";
+ vm.NewTypeNumber = 0;
+ vm.AddTruppCommand.Execute(null);
+
+ Assert.Null(vm.NewTypeNumberError);
+ }
+}
diff --git a/tests/LageBuch.AppLogic.Tests/ScbaRadiationTests.cs b/tests/LageBuch.AppLogic.Tests/ScbaRadiationTests.cs
new file mode 100644
index 000000000..71eef4981
--- /dev/null
+++ b/tests/LageBuch.AppLogic.Tests/ScbaRadiationTests.cs
@@ -0,0 +1,451 @@
+using LageBuch.AppLogic.ViewModels;
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+using LageBuch.Persistence.MasterData;
+
+namespace LageBuch.AppLogic.Tests;
+
+///
+/// The Strahlenschutzüberwachung of a Strahlenschutztrupp in the Atemschutz tab (#994): the row,
+/// the dialog, and the close refusal. The ETB wording is asserted literally: it is persisted and
+/// read back off the Einsatzbericht, so it is a data format.
+///
+public class ScbaRadiationTests
+{
+ private const string Strahlenschutztrupp = "Strahlenschutztrupp";
+
+ private static readonly DateTimeOffset T0 = new(2026, 6, 22, 9, 0, 0, TimeSpan.FromHours(2));
+
+ private static MasterDataSet Md() => MasterDataSet.Empty with
+ {
+ TruppTypes = new[] { new TruppType("Angriffstrupp"), new TruppType(Strahlenschutztrupp, 3, 30, RadiationMonitoring: true) },
+ };
+
+ private static LocalIncidentSession NewSession(FixedClock clock) =>
+ TestSession.StartNew(
+ new FakeStore(),
+ clock,
+ new SessionOperator("Müller", "FFB 12/1"),
+ "/x.lagebuch",
+ Array.Empty<(string, bool)>(),
+ Array.Empty<(string, bool)>());
+
+ private static ScbaViewModel Vm(FixedClock clock, LocalIncidentSession session, List? opened = null) =>
+ new(session, Md(), clock, new FakeTicker(), new FakeAlarmService(), () => { }, d => opened?.Add(d));
+
+ private static ScbaTruppRow Register(ScbaViewModel vm, string designation = Strahlenschutztrupp)
+ {
+ vm.NewDesignation = designation;
+ vm.NewCallSign = "HLF 1";
+ vm.NewTruppfuehrer = "Müller";
+ vm.NewTruppmann = "Schmidt";
+ vm.NewZweiterTruppmann = "Huber";
+ vm.AddTruppCommand.Execute(null);
+ return vm.Trupps[^1];
+ }
+
+ private static RadiationDialogViewModel Open(ScbaTruppRow row, List opened)
+ {
+ row.OpenRadiationCommand.Execute(null);
+ return opened[^1];
+ }
+
+ private static void Number(RadiationDialogViewModel dialog)
+ {
+ foreach (var (m, i) in dialog.Members.Select((m, i) => (m, i)))
+ {
+ m.OslNumber = $"OSL {i + 1}";
+ m.AlarmNumber = $"EPD {i + 1}";
+ }
+ }
+
+ [Fact]
+ public void A_strahlenschutztrupp_is_registered_under_the_ueberwachung_an_ordinary_one_is_not()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ using var vm = Vm(clock, session);
+
+ var row = Register(vm);
+ var ordinary = Register(vm, "Angriffstrupp");
+
+ Assert.True(session.Incident.ScbaTrupps[0].RadiationMonitoring);
+ Assert.True(row.IsRadiationMonitored);
+ Assert.False(ordinary.IsRadiationMonitored);
+ Assert.Null(ordinary.RadiationHint);
+ }
+
+ [Fact]
+ public void Im_einsatz_waits_for_the_dosimeter_numbers()
+ {
+ var clock = new FixedClock(T0);
+ var opened = new List();
+ using var vm = Vm(clock, NewSession(clock), opened);
+ var row = Register(vm);
+
+ Assert.Equal("Dosimeter-Nr. fehlen", row.RadiationHint);
+ Assert.False(row.StartCommand.CanExecute(null));
+
+ var dialog = Open(row, opened);
+ Number(dialog);
+ dialog.SaveCommand.Execute(null);
+
+ Assert.True(row.StartCommand.CanExecute(null));
+ Assert.Null(row.RadiationHint);
+ }
+
+ [Fact]
+ public void Saving_numbers_writes_one_etb_line_per_crew_member()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ var opened = new List();
+ using var vm = Vm(clock, session, opened);
+ var dialog = Open(Register(vm), opened);
+ var closed = false;
+ dialog.Closed += (_, _) => closed = true;
+
+ dialog.Members[0].OslNumber = "4711";
+ dialog.Members[0].AlarmNumber = "0815";
+ dialog.Members[0].MaskNumber = "12";
+ dialog.Members[0].PaNumber = "3";
+ dialog.SaveCommand.Execute(null);
+
+ Assert.True(closed);
+ var entry = Assert.Single(session.Incident.Journal, e => e.Text.Contains("Strahlenschutz Müller", StringComparison.Ordinal));
+ Assert.Equal(
+ "HLF 1 · Strahlenschutztrupp: Strahlenschutz Müller – OSL-Dosimeter 4711, Alarmdosimeter 0815, Maske 12, PA 3",
+ entry.Text);
+ Assert.Equal("HLF 1", entry.From);
+ Assert.DoesNotContain(session.Incident.Journal, e => e.Text.Contains("Strahlenschutz Schmidt", StringComparison.Ordinal));
+ }
+
+ // Declaring a dosimeter missing breaks the documentation chain, so it asks first.
+ [Fact]
+ public void Nicht_vorhanden_asks_first_and_cancelling_leaves_the_dosimeter_alone()
+ {
+ var clock = new FixedClock(T0);
+ var opened = new List();
+ using var vm = Vm(clock, NewSession(clock), opened);
+ var dialog = Open(Register(vm), opened);
+ var member = dialog.Members[1];
+
+ member.DeclareAlarmMissingCommand.Execute(null);
+
+ Assert.True(dialog.IsMissingPending);
+ Assert.Contains("Alarmdosimeter von Schmidt nicht vorhanden?", dialog.MissingWarning, StringComparison.Ordinal);
+ Assert.Contains("Dokumentationskette unterbrochen", dialog.MissingWarning, StringComparison.Ordinal);
+ Assert.False(member.AlarmMissing);
+
+ dialog.CancelMissingCommand.Execute(null);
+
+ Assert.False(dialog.IsMissingPending);
+ Assert.False(member.AlarmMissing);
+ }
+
+ [Fact]
+ public void A_confirmed_missing_dosimeter_is_recorded_with_an_achtung_line()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ var opened = new List();
+ using var vm = Vm(clock, session, opened);
+ var row = Register(vm);
+ var dialog = Open(row, opened);
+ Number(dialog);
+ dialog.Members[1].DoseText = "0,5";
+
+ dialog.Members[1].DeclareAlarmMissingCommand.Execute(null);
+ dialog.ConfirmMissingCommand.Execute(null);
+ dialog.SaveCommand.Execute(null);
+
+ var record = session.Incident.ScbaTrupps[0].Members[1].Radiation;
+ Assert.True(record?.AlarmDosimeterMissing);
+ Assert.Null(record?.AlarmReading); // a missing Alarmdosimeter has nothing to read off
+ Assert.Contains(
+ session.Incident.Journal,
+ e => e.Text == "ACHTUNG HLF 1 · Strahlenschutztrupp: Alarmdosimeter von Schmidt nicht vorhanden – Dokumentationskette unterbrochen");
+ }
+
+ [Theory]
+ [InlineData("0,12", DoseUnit.MilliSievert, "0,12 mSv")]
+ [InlineData("0.12", DoseUnit.MilliSievert, "0,12 mSv")]
+ [InlineData("35", DoseUnit.MicroSievert, "35 µSv")]
+ public void A_reading_is_kept_with_its_unit_and_logged(string typed, DoseUnit unit, string expected)
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ var opened = new List();
+ using var vm = Vm(clock, session, opened);
+ var dialog = Open(Register(vm), opened);
+ Number(dialog);
+
+ dialog.Members[0].DoseText = typed;
+ dialog.Members[0].DoseUnit = unit;
+ dialog.SaveCommand.Execute(null);
+
+ Assert.Equal(expected, session.Incident.ScbaTrupps[0].Members[0].Radiation?.AlarmReading?.Display);
+ Assert.Contains(
+ session.Incident.Journal,
+ e => e.Text == $"HLF 1 · Strahlenschutztrupp: Ablesewert Alarmdosimeter Müller: {expected}");
+ }
+
+ [Fact]
+ public void The_unit_defaults_to_msv()
+ {
+ var clock = new FixedClock(T0);
+ var opened = new List();
+ using var vm = Vm(clock, NewSession(clock), opened);
+ var dialog = Open(Register(vm), opened);
+
+ Assert.All(dialog.Members, m => Assert.Equal(DoseUnit.MilliSievert, m.DoseUnit));
+ Assert.Equal("mSv", dialog.Members[0].DoseUnitLabel);
+
+ dialog.Members[0].DoseUnitLabel = "µSv";
+ Assert.Equal(DoseUnit.MicroSievert, dialog.Members[0].DoseUnit);
+ }
+
+ [Theory]
+ [InlineData("abc")]
+ [InlineData("-1")]
+ [InlineData("1.000,5")]
+ [InlineData("999999")]
+ public void A_reading_that_is_no_number_stays_in_the_field_with_a_message(string typed)
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ var opened = new List();
+ using var vm = Vm(clock, session, opened);
+ var dialog = Open(Register(vm), opened);
+ var closed = false;
+ dialog.Closed += (_, _) => closed = true;
+
+ dialog.Members[0].DoseText = typed;
+ dialog.SaveCommand.Execute(null);
+
+ Assert.False(closed);
+ Assert.Equal("Ablesewert als Zahl eingeben, z. B. 0,12", dialog.Members[0].DoseError);
+ Assert.Equal(typed, dialog.Members[0].DoseText);
+ Assert.Equal(RadiationRecord.Empty, session.Incident.ScbaTrupps[0].Members[0].Radiation);
+ }
+
+ [Fact]
+ public void An_abgenommen_trupp_without_its_readings_says_so()
+ {
+ var clock = new FixedClock(T0);
+ var opened = new List();
+ using var vm = Vm(clock, NewSession(clock), opened);
+ var row = Register(vm);
+ var dialog = Open(row, opened);
+ Number(dialog);
+ dialog.SaveCommand.Execute(null);
+
+ row.StartCommand.Execute(null);
+ row.WithdrawCommand.Execute(null);
+ row.MarkRemovedCommand.Execute(null);
+
+ Assert.True(row.IsReturned);
+ Assert.Equal("Ablesewert offen", row.RadiationHint);
+ }
+
+ [Fact]
+ public void An_unchanged_dialog_writes_nothing()
+ {
+ var clock = new FixedClock(T0);
+ var session = NewSession(clock);
+ var opened = new List();
+ using var vm = Vm(clock, session, opened);
+ var dialog = Open(Register(vm), opened);
+ var before = session.Incident.Journal.Count;
+
+ dialog.SaveCommand.Execute(null);
+
+ Assert.Equal(before, session.Incident.Journal.Count);
+ }
+
+ private static readonly RadiationRecord Numbered = new("4711", false, "0815", false, "12", "3");
+
+ private static (LocalIncidentSession Session, Guid TruppId) SessionWithStrahlenschutztrupp()
+ {
+ var session = NewSession(new FixedClock(T0));
+ session.AddScbaTrupp(Strahlenschutztrupp, TruppMember.Crew("Müller", "Schmidt"), 300, callSign: "HLF 1", radiationMonitoring: true);
+ return (session, session.Incident.ScbaTrupps[0].Id);
+ }
+
+ [Theory]
+ [InlineData("4799", "0815", "12", "3")]
+ [InlineData("4711", "0899", "12", "3")]
+ [InlineData("4711", "0815", "99", "3")]
+ [InlineData("4711", "0815", "12", "99")]
+ public void Any_changed_number_writes_the_numbers_line(string osl, string alarm, string mask, string pa)
+ {
+ var after = new RadiationRecord(osl, false, alarm, false, mask, pa);
+
+ var line = Assert.Single(RadiationDialogViewModel.JournalLines("T", "Müller", Numbered, after));
+
+ Assert.Equal($"T: Strahlenschutz Müller – {after.NumbersDisplay}", line);
+ }
+
+ [Fact]
+ public void Unchanged_numbers_and_an_unchanged_reading_write_nothing()
+ {
+ var withReading = Numbered.WithAlarmReading(new DoseReading(1m, DoseUnit.MilliSievert));
+
+ Assert.Empty(RadiationDialogViewModel.JournalLines("T", "Müller", withReading, withReading));
+ }
+
+ [Fact]
+ public void A_missing_osl_dosimeter_writes_its_achtung_line_once()
+ {
+ var missing = new RadiationRecord("4711", true, "0815", false, "12", "3");
+
+ Assert.Equal(
+ new[] { "ACHTUNG T: OSL-Dosimeter von Müller nicht vorhanden – Dokumentationskette unterbrochen" },
+ RadiationDialogViewModel.JournalLines("T", "Müller", Numbered, missing));
+ Assert.Empty(RadiationDialogViewModel.JournalLines("T", "Müller", missing, missing));
+ Assert.Empty(RadiationDialogViewModel.JournalLines("T", "Müller", missing, Numbered));
+ }
+
+ [Fact]
+ public void A_missing_alarmdosimeter_already_declared_is_not_logged_again()
+ {
+ var missing = new RadiationRecord("4711", false, "0815", true, "12", "3");
+
+ Assert.Empty(RadiationDialogViewModel.JournalLines("T", "Müller", missing, missing));
+ }
+
+ [Fact]
+ public void A_confirmed_osl_declaration_lands_on_the_osl_dosimeter()
+ {
+ var (session, truppId) = SessionWithStrahlenschutztrupp();
+ var dialog = new RadiationDialogViewModel(session, truppId);
+
+ dialog.Members[0].DeclareOslMissingCommand.Execute(null);
+ Assert.StartsWith("OSL-Dosimeter von Müller nicht vorhanden?", dialog.MissingWarning, StringComparison.Ordinal);
+ dialog.ConfirmMissingCommand.Execute(null);
+
+ Assert.True(dialog.Members[0].OslMissing);
+ Assert.False(dialog.Members[0].OslPresent);
+ Assert.True(dialog.Members[0].AlarmPresent);
+ Assert.False(dialog.IsMissingPending);
+ }
+
+ [Fact]
+ public void A_saved_change_is_reported_and_an_unchanged_reopen_is_not()
+ {
+ var (session, truppId) = SessionWithStrahlenschutztrupp();
+ var changes = 0;
+ var dialog = new RadiationDialogViewModel(session, truppId, () => changes++);
+ dialog.Members[0].OslNumber = "4711";
+ dialog.Members[0].AlarmNumber = "0815";
+ dialog.SaveCommand.Execute(null);
+ Assert.Equal(1, changes);
+ var journal = session.Incident.Journal.Count;
+
+ var reopened = new RadiationDialogViewModel(session, truppId, () => changes++);
+ var closed = false;
+ reopened.Closed += (_, _) => closed = true;
+ reopened.SaveCommand.Execute(null);
+
+ Assert.True(closed);
+ Assert.Equal(1, changes);
+ Assert.Equal(journal, session.Incident.Journal.Count);
+ }
+
+ [Fact]
+ public void A_refused_save_keeps_the_dialog_open_with_the_reason()
+ {
+ var (session, truppId) = SessionWithStrahlenschutztrupp();
+ var dialog = new RadiationDialogViewModel(session, truppId);
+ var closed = false;
+ dialog.Closed += (_, _) => closed = true;
+
+ dialog.Members[0].OslNumber = new string('9', RadiationRecord.MaxNumberLength + 1);
+ dialog.SaveCommand.Execute(null);
+
+ Assert.False(closed);
+ Assert.Equal("Nicht möglich: Eine Nummer darf höchstens 50 Zeichen lang sein.", dialog.SaveError);
+ }
+
+ [Fact]
+ public void A_closed_einsatz_opens_the_dialog_to_read_but_not_to_save()
+ {
+ var (session, truppId) = SessionWithStrahlenschutztrupp();
+ session.Close();
+
+ var dialog = new RadiationDialogViewModel(session, truppId);
+
+ Assert.False(dialog.SaveCommand.CanExecute(null));
+ }
+
+ [Fact]
+ public void A_row_shows_what_is_recorded()
+ {
+ var member = new TruppMember(
+ TruppRole.Truppmann, "Schmidt", Numbered.WithAlarmReading(new DoseReading(0.125m, DoseUnit.MicroSievert)));
+
+ var row = new RadiationMemberRow(member, (_, _) => { });
+
+ Assert.Equal(("4711", "0815", "12", "3"), (row.OslNumber, row.AlarmNumber, row.MaskNumber, row.PaNumber));
+ Assert.Equal("0,125", row.DoseText);
+ Assert.Equal(DoseUnit.MicroSievert, row.DoseUnit);
+ Assert.Equal("Truppmann", row.RoleDisplay);
+
+ row.DoseUnitLabel = "mSv";
+ Assert.Equal(DoseUnit.MilliSievert, row.DoseUnit);
+ row.DoseUnitLabel = null;
+ Assert.Equal(DoseUnit.MilliSievert, row.DoseUnit);
+ }
+
+ [Fact]
+ public void Undo_and_un_declaring_restore_a_dosimeter_and_keep_the_reading()
+ {
+ var row = new RadiationMemberRow(new TruppMember(TruppRole.Truppfuehrer, "Müller", Numbered), (_, _) => { });
+ row.DoseText = "0,5";
+
+ row.SetMissing(DosimeterKind.Osl, true);
+ row.SetMissing(DosimeterKind.Alarm, true);
+ Assert.True(row.OslMissing);
+ Assert.False(row.AlarmPresent);
+ Assert.Null(row.DoseText);
+
+ row.UndoOslMissingCommand.Execute(null);
+ row.UndoAlarmMissingCommand.Execute(null);
+ Assert.True(row.OslPresent);
+ Assert.True(row.AlarmPresent);
+
+ row.DoseText = "0,5";
+ row.SetMissing(DosimeterKind.Alarm, false);
+ Assert.Equal("0,5", row.DoseText);
+ }
+
+ [Theory]
+ [InlineData("100000", true)]
+ [InlineData("100000.001", false)]
+ [InlineData(" ", false)]
+ [InlineData(null, false)]
+ public void The_reading_limit_itself_is_a_number(string? text, bool expected)
+ {
+ Assert.Equal(expected, RadiationMemberRow.TryParseDose(text, out _));
+ }
+
+ [Fact]
+ public void The_row_hint_updates_when_the_numbers_come_in()
+ {
+ var clock = new FixedClock(T0);
+ var opened = new List();
+ using var vm = Vm(clock, NewSession(clock), opened);
+ var row = Register(vm);
+ Assert.True(row.HasRadiationHint);
+ var raised = new List();
+ row.PropertyChanged += (_, e) => raised.Add(e.PropertyName);
+
+ var dialog = Open(row, opened);
+ Number(dialog);
+ dialog.SaveCommand.Execute(null);
+
+ Assert.Contains(nameof(ScbaTruppRow.RadiationHint), raised);
+ Assert.Contains(nameof(ScbaTruppRow.HasRadiationHint), raised);
+ Assert.False(row.HasRadiationHint);
+ }
+}
diff --git a/tests/LageBuch.Documents.Tests/AtemschutzSectionTests.cs b/tests/LageBuch.Documents.Tests/AtemschutzSectionTests.cs
index 724502e12..4cc4cccf2 100644
--- a/tests/LageBuch.Documents.Tests/AtemschutzSectionTests.cs
+++ b/tests/LageBuch.Documents.Tests/AtemschutzSectionTests.cs
@@ -169,4 +169,61 @@ private sealed class FixedClock(DateTimeOffset now) : IClock
{
public DateTimeOffset Now { get; set; } = now;
}
+
+ // #994: a Strahlenschutztrupp's crew, one line each, with the gap a missing dosimeter leaves.
+ [Fact]
+ public void Radiation_lines_list_numbers_and_readings_and_mark_a_gap()
+ {
+ var clock = new FixedClock(Started);
+ var incident = Incident.Start(clock, new SessionOperator("Huber", "FFB 12/1"));
+ var trupp = incident.AddScbaTrupp(
+ clock, "Strahlenschutztrupp", TruppMember.Crew("Müller", "Schmidt"), entryPressure: 300, radiationMonitoring: true);
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.Truppfuehrer, new RadiationRecord("4711", false, "0815", false, "12", "3", new DoseReading(0.12m, DoseUnit.MilliSievert)));
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.Truppmann, new RadiationRecord("4712", false, "0816", alarmDosimeterMissing: true));
+
+ Assert.Equal(
+ new[]
+ {
+ ("Strahlenschutz Müller (Truppführer): OSL-Dosimeter 4711, Alarmdosimeter 0815, Maske 12, PA 3 · Ablesewert 0,12 mSv", false),
+ ("Strahlenschutz Schmidt (Truppmann): OSL-Dosimeter 4712, Alarmdosimeter 0816 (nicht vorhanden), Maske —, PA — · Ablesewert: nicht vorhanden", true),
+ },
+ AtemschutzSection.RadiationLines(trupp));
+ }
+
+ [Fact]
+ public void An_ordinary_trupp_has_no_radiation_lines()
+ {
+ var (_, trupp, _) = UnderAir();
+
+ Assert.Empty(AtemschutzSection.RadiationLines(trupp));
+ }
+
+ [Fact]
+ public void Pdf_prints_the_strahlenschutz_lines()
+ {
+ var clock = new FixedClock(Started);
+ var incident = Incident.Start(clock, new SessionOperator("Huber", "FFB 12/1"));
+ var trupp = incident.AddScbaTrupp(
+ clock, "Strahlenschutztrupp", TruppMember.Crew("Müller", "Schmidt"), entryPressure: 300, radiationMonitoring: true);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, new RadiationRecord("4711", false, "0815", false));
+
+ var text = PdfText.Of(incident, Started, IncidentPdfSections.Atemschutz);
+
+ Assert.Contains("Strahlenschutz Müller (Truppführer)", text, StringComparison.Ordinal);
+ Assert.Contains("Ablesewert offen", text, StringComparison.Ordinal);
+ }
+
+ [Fact]
+ public void A_gap_prints_dark_red_and_semibold_everything_else_grey()
+ {
+ var (gapColor, gapWeight) = AtemschutzSection.RadiationLineStyle(gap: true);
+ var (plainColor, plainWeight) = AtemschutzSection.RadiationLineStyle(gap: false);
+
+ Assert.Equal(QuestPDF.Helpers.Colors.Red.Darken3, gapColor);
+ Assert.Equal(QuestPDF.Infrastructure.FontWeight.SemiBold, gapWeight);
+ Assert.Equal(QuestPDF.Helpers.Colors.Grey.Darken1, plainColor);
+ Assert.Equal(QuestPDF.Infrastructure.FontWeight.Normal, plainWeight);
+ }
}
diff --git a/tests/LageBuch.Domain.Tests/AtemschutzTests.cs b/tests/LageBuch.Domain.Tests/AtemschutzTests.cs
index 27c24ebc5..7c613ee66 100644
--- a/tests/LageBuch.Domain.Tests/AtemschutzTests.cs
+++ b/tests/LageBuch.Domain.Tests/AtemschutzTests.cs
@@ -681,6 +681,67 @@ public void DisplayName_is_the_designation_alone_without_a_funkrufname(string? c
Assert.Equal("Wassertrupp", AtemschutzTrupp.FormatDisplayName(callSign, "Wassertrupp"));
}
+ // #995: a CSA-Trupp is called by its number. Its Funkrufname already names the Trupp-Art, so
+ // repeating it ("CSA-Trupp 1 · CSA-Trupp") -- or prefixing the bare number ("1 · CSA-Trupp")
+ // -- is what made the row unreadable.
+ [Theory]
+ [InlineData("CSA-Trupp 1", "CSA-Trupp 1")]
+ [InlineData("CSA-Trupp", "CSA-Trupp")]
+ [InlineData(" CSA-Trupp 12 ", "CSA-Trupp 12")]
+ public void Display_name_is_the_call_sign_alone_when_it_already_names_the_trupp_art(string callSign, string expected)
+ {
+ Assert.Equal(expected, AtemschutzTrupp.FormatDisplayName(callSign, "CSA-Trupp"));
+ }
+
+ [Theory]
+ [InlineData("HLF 1", "Angriffstrupp", "HLF 1 · Angriffstrupp")]
+ [InlineData("CSA-Truppführer", "CSA-Trupp", "CSA-Truppführer · CSA-Trupp")]
+ [InlineData("CSA-Trupp 1", "Angriffstrupp", "CSA-Trupp 1 · Angriffstrupp")]
+ public void Display_name_keeps_call_sign_and_trupp_art_otherwise(string callSign, string designation, string expected)
+ {
+ Assert.Equal(expected, AtemschutzTrupp.FormatDisplayName(callSign, designation));
+ }
+
+ [Fact]
+ public void Numbered_call_sign_is_the_trupp_art_and_the_number()
+ {
+ Assert.Equal("CSA-Trupp 3", AtemschutzTrupp.NumberedCallSign(" CSA-Trupp ", 3));
+ }
+
+ // Numbered per Trupp-Art: two Angriffstrupps before it do not make the first CSA-Trupp "3".
+ [Fact]
+ public void Next_free_type_number_counts_per_trupp_art()
+ {
+ var incident = NewIncident(out var clock);
+ incident.AddScbaTrupp(clock, "Angriffstrupp", TruppMember.Crew("Müller", "Schmidt"), entryPressure: 300, callSign: "HLF 1");
+ incident.AddScbaTrupp(clock, "Angriffstrupp", TruppMember.Crew("Huber", "Bauer"), entryPressure: 300, callSign: "HLF 2");
+
+ Assert.Equal(1, incident.NextFreeTypeNumber("CSA-Trupp"));
+
+ incident.AddScbaTrupp(
+ clock, "CSA-Trupp", TruppMember.Crew("Maier", "Wagner", "Fischer"), entryPressure: 300, callSign: "CSA-Trupp 1");
+
+ Assert.Equal(2, incident.NextFreeTypeNumber("CSA-Trupp"));
+ Assert.True(incident.IsTypeNumberInUse("CSA-Trupp", 1));
+ Assert.False(incident.IsTypeNumberInUse("CSA-Trupp", 2));
+ Assert.Equal(1, incident.NextFreeTypeNumber("Angriffstrupp"));
+ }
+
+ // A number stays taken after Abnehmen: the radio name of a Trupp that has come out must not
+ // be handed to the next one, or the ETB can no longer tell the two apart.
+ [Fact]
+ public void Type_number_of_an_abgenommen_trupp_stays_taken()
+ {
+ var incident = NewIncident(out var clock);
+ var first = incident.AddScbaTrupp(
+ clock, "CSA-Trupp", TruppMember.Crew("Maier", "Wagner", "Fischer"), entryPressure: 300, callSign: "CSA-Trupp 1");
+ first.Start(T0);
+ first.Withdraw(T0.AddMinutes(18));
+ first.MarkRemoved(T0.AddMinutes(20));
+
+ Assert.Equal(2, incident.NextFreeTypeNumber("CSA-Trupp"));
+ }
+
[Fact]
public void FormatDisplayName_matches_the_instance_property()
{
diff --git a/tests/LageBuch.Domain.Tests/StrahlenschutzTests.cs b/tests/LageBuch.Domain.Tests/StrahlenschutzTests.cs
new file mode 100644
index 000000000..9241d9619
--- /dev/null
+++ b/tests/LageBuch.Domain.Tests/StrahlenschutzTests.cs
@@ -0,0 +1,347 @@
+using LageBuch.Domain.Atemschutz;
+
+namespace LageBuch.Domain.Tests;
+
+/// Strahlenschutzüberwachung of a Strahlenschutztrupp (#994).
+public class StrahlenschutzTests
+{
+ private static readonly DateTimeOffset T0 = new(2026, 6, 22, 9, 0, 0, TimeSpan.FromHours(2));
+
+ private static readonly RadiationRecord Numbered = new(oslDosimeterNumber: "OSL 1", alarmDosimeterNumber: "EPD 7");
+
+ private static Incident NewIncident(out FixedClock clock)
+ {
+ clock = new FixedClock(T0);
+ return Incident.Start(clock, new SessionOperator("Müller", "FFB 12/1"));
+ }
+
+ private static AtemschutzTrupp AddStrahlenschutztrupp(Incident incident, FixedClock clock) =>
+ incident.AddScbaTrupp(
+ clock,
+ "Strahlenschutztrupp",
+ TruppMember.Crew("Müller", "Schmidt", "Huber"),
+ entryPressure: 300,
+ callSign: "HLF 1",
+ radiationMonitoring: true);
+
+ private static void NumberEveryone(Incident incident, AtemschutzTrupp trupp)
+ {
+ foreach (var m in trupp.Members.ToList())
+ {
+ incident.RecordScbaRadiation(trupp.Id, m.Role, Numbered);
+ }
+ }
+
+ [Fact]
+ public void Every_crew_member_of_a_strahlenschutztrupp_starts_with_an_empty_record()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+
+ Assert.True(trupp.RadiationMonitoring);
+ Assert.All(trupp.Members, m => Assert.Equal(RadiationRecord.Empty, m.Radiation));
+ }
+
+ [Fact]
+ public void An_ordinary_trupp_carries_no_record_even_if_handed_one()
+ {
+ var incident = NewIncident(out var clock);
+ var crew = TruppMember.Crew("Müller", "Schmidt").Select(m => m with { Radiation = Numbered });
+ var trupp = incident.AddScbaTrupp(clock, "Angriffstrupp", crew, entryPressure: 300);
+
+ Assert.False(trupp.RadiationMonitoring);
+ Assert.All(trupp.Members, m => Assert.Null(m.Radiation));
+ Assert.Throws(
+ () => incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, Numbered));
+ }
+
+ [Fact]
+ public void A_strahlenschutztrupp_without_dosimeter_numbers_cannot_go_under_atemschutz()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, Numbered);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppmann, Numbered);
+
+ Assert.True(trupp.LacksDosimeterNumbers);
+ var ex = Assert.Throws(() => incident.StartScbaTrupp(clock, trupp.Id));
+ Assert.Contains("Dosimeter-Nummern fehlen", ex.Message, StringComparison.Ordinal);
+ Assert.False(trupp.HasStarted);
+ }
+
+ // Maske and PA are optional; a dosimeter declared missing counts as accounted for.
+ [Fact]
+ public void Numbers_or_a_declared_missing_dosimeter_let_the_trupp_start()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, Numbered);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppmann, Numbered);
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.ZweiterTruppmann, new RadiationRecord(oslDosimeterMissing: true, alarmDosimeterNumber: "EPD 9"));
+
+ incident.StartScbaTrupp(clock, trupp.Id);
+
+ Assert.True(trupp.HasStarted);
+ }
+
+ [Fact]
+ public void An_osl_number_alone_is_not_enough()
+ {
+ Assert.False(new RadiationRecord(oslDosimeterNumber: "OSL 1").HasDosimeterNumbers);
+ Assert.False(new RadiationRecord(alarmDosimeterNumber: "EPD 1").HasDosimeterNumbers);
+ Assert.True(new RadiationRecord(oslDosimeterMissing: true, alarmDosimeterMissing: true).HasDosimeterNumbers);
+ }
+
+ [Fact]
+ public void A_started_strahlenschutztrupp_awaits_a_reading_until_every_alarmdosimeter_is_answered()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ NumberEveryone(incident, trupp);
+ Assert.False(trupp.AwaitsDoseReading); // not under Atemschutz yet: no dose to report
+
+ incident.StartScbaTrupp(clock, trupp.Id);
+ Assert.True(trupp.AwaitsDoseReading);
+
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.Truppfuehrer, Numbered.WithAlarmReading(new DoseReading(0.12m, DoseUnit.MilliSievert)));
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.Truppmann, Numbered.WithAlarmReading(new DoseReading(35m, DoseUnit.MicroSievert)));
+ Assert.True(trupp.AwaitsDoseReading);
+
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.ZweiterTruppmann, new RadiationRecord("OSL 3", false, "EPD 3", alarmDosimeterMissing: true));
+ Assert.False(trupp.AwaitsDoseReading);
+ }
+
+ // The Dekon-Platz reports late, so the reading must still be recordable after Abnehmen.
+ [Fact]
+ public void A_reading_can_be_recorded_after_abnehmen()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ NumberEveryone(incident, trupp);
+ incident.StartScbaTrupp(clock, trupp.Id);
+ incident.WithdrawScbaTrupp(clock, trupp.Id);
+ incident.MarkScbaRemoved(clock, trupp.Id);
+
+ incident.RecordScbaRadiation(
+ trupp.Id, TruppRole.Truppfuehrer, Numbered.WithAlarmReading(new DoseReading(0.5m, DoseUnit.MilliSievert)));
+
+ Assert.Equal(new DoseReading(0.5m, DoseUnit.MilliSievert), trupp.Members[0].Radiation?.AlarmReading);
+ }
+
+ [Fact]
+ public void The_einsatz_cannot_be_closed_while_a_reading_is_missing()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ NumberEveryone(incident, trupp);
+ incident.StartScbaTrupp(clock, trupp.Id);
+
+ var ex = Assert.Throws(
+ () => incident.Close(clock, new SessionOperator("Müller", "FFB 12/1")));
+ Assert.Equal("Ablesewerte fehlen: HLF 1 · Strahlenschutztrupp.", ex.Message);
+ Assert.Equal(IncidentState.Open, incident.State);
+ Assert.Equal(new[] { trupp }, incident.ScbaTruppsAwaitingDoseReading);
+
+ foreach (var m in trupp.Members.ToList())
+ {
+ incident.RecordScbaRadiation(
+ trupp.Id, m.Role, Numbered.WithAlarmReading(new DoseReading(0m, DoseUnit.MicroSievert)));
+ }
+
+ incident.Close(clock, new SessionOperator("Müller", "FFB 12/1"));
+ Assert.Equal(IncidentState.Closed, incident.State);
+ }
+
+ [Fact]
+ public void A_missing_alarmdosimeter_has_no_reading()
+ {
+ Assert.Throws(
+ () => new RadiationRecord(alarmDosimeterMissing: true, alarmReading: new DoseReading(1m, DoseUnit.MilliSievert)));
+ }
+
+ [Fact]
+ public void Numbers_are_trimmed_and_capped()
+ {
+ var record = new RadiationRecord(oslDosimeterNumber: " OSL 1 ", maskNumber: " ");
+
+ Assert.Equal("OSL 1", record.OslDosimeterNumber);
+ Assert.Null(record.MaskNumber);
+ Assert.Throws(
+ () => new RadiationRecord(paNumber: new string('9', RadiationRecord.MaxNumberLength + 1)));
+ }
+
+ [Theory]
+ [InlineData(0.12, DoseUnit.MilliSievert, "0,12 mSv")]
+ [InlineData(35, DoseUnit.MicroSievert, "35 µSv")]
+ [InlineData(0.003, DoseUnit.MilliSievert, "0,003 mSv")]
+ public void A_reading_reads_the_way_the_display_showed_it(double value, DoseUnit unit, string expected)
+ {
+ Assert.Equal(expected, new DoseReading((decimal)value, unit).Display);
+ }
+
+ [Fact]
+ public void A_negative_or_absurd_reading_is_refused()
+ {
+ Assert.Throws(() => new DoseReading(-0.1m, DoseUnit.MilliSievert));
+ Assert.Throws(() => new DoseReading(DoseReading.MaxValue + 1, DoseUnit.MilliSievert));
+ Assert.Throws(() => new DoseReading(1m, (DoseUnit)7));
+ }
+
+ // Every Trupp still owing a reading is named, in Trupp order, so the refusal says where to look.
+ [Fact]
+ public void The_refusal_names_every_trupp_still_owing_a_reading_in_trupp_order()
+ {
+ var incident = NewIncident(out var clock);
+ var second = incident.AddScbaTrupp(
+ clock, "Strahlenschutztrupp", TruppMember.Crew("Maier", "Wagner"), entryPressure: 300, truppNumber: 2, callSign: "B", radiationMonitoring: true);
+ var first = incident.AddScbaTrupp(
+ clock, "Strahlenschutztrupp", TruppMember.Crew("Bauer", "Klein"), entryPressure: 300, truppNumber: 1, callSign: "A", radiationMonitoring: true);
+ foreach (var trupp in new[] { second, first })
+ {
+ NumberEveryone(incident, trupp);
+ incident.StartScbaTrupp(clock, trupp.Id);
+ }
+
+ Assert.Equal(new[] { first, second }, incident.ScbaTruppsAwaitingDoseReading);
+ var ex = Assert.Throws(
+ () => incident.Close(clock, new SessionOperator("Müller", "FFB 12/1")));
+ Assert.Equal("Ablesewerte fehlen: A · Strahlenschutztrupp, B · Strahlenschutztrupp.", ex.Message);
+ }
+
+ [Fact]
+ public void A_closed_einsatz_takes_no_more_records()
+ {
+ var incident = NewIncident(out var clock);
+ var trupp = AddStrahlenschutztrupp(incident, clock);
+ incident.Close(clock, new SessionOperator("Müller", "FFB 12/1"));
+
+ Assert.Throws(
+ () => incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, Numbered));
+ Assert.Equal(RadiationRecord.Empty, trupp.Members[0].Radiation);
+ }
+
+ // A record handed in at registration is kept, not overwritten by the empty one.
+ [Fact]
+ public void A_record_handed_in_at_registration_is_kept()
+ {
+ var incident = NewIncident(out var clock);
+ var crew = TruppMember.Crew("Müller", "Schmidt").Select(m => m with { Radiation = Numbered });
+
+ var trupp = incident.AddScbaTrupp(clock, "Strahlenschutztrupp", crew, entryPressure: 300, radiationMonitoring: true);
+
+ Assert.All(trupp.Members, m => Assert.Equal(Numbered, m.Radiation));
+ }
+
+ [Fact]
+ public void Refusals_say_why_in_german()
+ {
+ var incident = NewIncident(out var clock);
+ var ordinary = incident.AddScbaTrupp(clock, "Angriffstrupp", TruppMember.Crew("Müller", "Schmidt"), entryPressure: 300);
+ var twoPerson = incident.AddScbaTrupp(
+ clock, "Strahlenschutztrupp", TruppMember.Crew("Bauer", "Klein"), entryPressure: 300, radiationMonitoring: true);
+
+ Assert.Equal(
+ "Dieser Trupp steht nicht unter Strahlenschutzüberwachung.",
+ Assert.Throws(() => ordinary.RecordRadiation(TruppRole.Truppfuehrer, Numbered)).Message);
+ Assert.StartsWith(
+ "Diese Truppfunktion ist nicht besetzt.",
+ Assert.Throws(() => twoPerson.RecordRadiation(TruppRole.ZweiterTruppmann, Numbered)).Message,
+ StringComparison.Ordinal);
+ Assert.StartsWith(
+ "Der Ablesewert muss zwischen 0 und 100.000 liegen.",
+ Assert.Throws(() => new DoseReading(-1m, DoseUnit.MilliSievert)).Message,
+ StringComparison.Ordinal);
+ Assert.StartsWith(
+ "Unbekannte Einheit.",
+ Assert.Throws(() => new DoseReading(1m, (DoseUnit)7)).Message,
+ StringComparison.Ordinal);
+ var reading = new DoseReading(1m, DoseUnit.MilliSievert);
+ var readingBesideMissing = Assert.Throws(
+ () => new RadiationRecord(alarmDosimeterMissing: true, alarmReading: reading));
+ Assert.StartsWith(
+ "Ein Alarmdosimeter, das nicht vorhanden ist, hat keinen Ablesewert.", readingBesideMissing.Message, StringComparison.Ordinal);
+ Assert.StartsWith(
+ "Eine Nummer darf höchstens 50 Zeichen lang sein.",
+ Assert.Throws(() => new RadiationRecord(maskNumber: new string('9', 51))).Message,
+ StringComparison.Ordinal);
+ }
+
+ [Fact]
+ public void The_limits_themselves_are_accepted()
+ {
+ Assert.Equal(DoseReading.MaxValue, new DoseReading(DoseReading.MaxValue, DoseUnit.MicroSievert).Value);
+ Assert.Equal(0m, new DoseReading(0m, DoseUnit.MicroSievert).Value);
+ var longest = new string('9', RadiationRecord.MaxNumberLength);
+ Assert.Equal(longest, new RadiationRecord(paNumber: longest).PaNumber);
+ }
+
+ [Theory]
+ [InlineData(DoseUnit.MilliSievert, "mSv")]
+ [InlineData(DoseUnit.MicroSievert, "µSv")]
+ public void Unit_labels(DoseUnit unit, string label) => Assert.Equal(label, DoseReading.UnitLabel(unit));
+
+ [Fact]
+ public void The_numbers_read_with_dashes_and_missing_marks()
+ {
+ Assert.Equal(
+ "OSL-Dosimeter 4711, Alarmdosimeter 0815, Maske 12, PA 3",
+ new RadiationRecord("4711", false, "0815", false, "12", "3").NumbersDisplay);
+ Assert.Equal(
+ "OSL-Dosimeter — (nicht vorhanden), Alarmdosimeter 0815 (nicht vorhanden), Maske —, PA —",
+ new RadiationRecord(oslDosimeterMissing: true, alarmDosimeterNumber: "0815", alarmDosimeterMissing: true).NumbersDisplay);
+ }
+
+ [Fact]
+ public void The_reading_line_says_value_missing_or_open()
+ {
+ Assert.Equal("Ablesewert 0,12 mSv", Numbered.WithAlarmReading(new DoseReading(0.12m, DoseUnit.MilliSievert)).ReadingDisplay);
+ Assert.Equal("Ablesewert: nicht vorhanden", new RadiationRecord(alarmDosimeterMissing: true).ReadingDisplay);
+ Assert.Equal("Ablesewert offen", Numbered.ReadingDisplay);
+ }
+
+ [Fact]
+ public void Either_missing_dosimeter_is_a_gap()
+ {
+ Assert.False(Numbered.HasGap);
+ Assert.True(new RadiationRecord(oslDosimeterMissing: true).HasGap);
+ Assert.True(new RadiationRecord(alarmDosimeterMissing: true).HasGap);
+ }
+
+ // FromUntrusted is how a handed-over file and a host's snapshot are read: it cuts and drops
+ // where the checking constructor would throw.
+ [Fact]
+ public void An_untrusted_record_is_cut_and_cleaned_never_refused()
+ {
+ var longest = new string('9', RadiationRecord.MaxNumberLength);
+ var record = RadiationRecord.FromUntrusted(longest + "99", false, longest, false, "12", "3", 0.5m, (int)DoseUnit.MicroSievert);
+
+ Assert.Equal(new RadiationRecord(longest, false, longest, false, "12", "3", new DoseReading(0.5m, DoseUnit.MicroSievert)), record);
+ }
+
+ [Theory]
+ [InlineData(-0.001, 0)]
+ [InlineData(100000.001, 0)]
+ [InlineData(1.0, 7)]
+ public void An_untrusted_reading_out_of_range_or_unit_is_dropped(double value, int unit)
+ {
+ Assert.Null(RadiationRecord.FromUntrusted(null, false, null, false, null, null, (decimal)value, unit).AlarmReading);
+ }
+
+ [Fact]
+ public void An_untrusted_reading_at_the_limits_or_beside_a_missing_dosimeter()
+ {
+ Assert.Equal(
+ new DoseReading(0m, DoseUnit.MilliSievert),
+ RadiationRecord.FromUntrusted(null, false, null, false, null, null, 0m, 0).AlarmReading);
+ Assert.Equal(
+ new DoseReading(DoseReading.MaxValue, DoseUnit.MilliSievert),
+ RadiationRecord.FromUntrusted(null, false, null, false, null, null, DoseReading.MaxValue, 0).AlarmReading);
+ Assert.Null(RadiationRecord.FromUntrusted(null, false, null, true, null, null, 1m, 0).AlarmReading);
+ Assert.Null(RadiationRecord.FromUntrusted(null, false, null, false, null, null, null, 0).AlarmReading);
+ Assert.Null(RadiationRecord.FromUntrusted(null, false, null, false, null, null, 1m, null).AlarmReading);
+ }
+}
diff --git a/tests/LageBuch.Persistence.Tests/MasterDataJsonTests.cs b/tests/LageBuch.Persistence.Tests/MasterDataJsonTests.cs
index c878f01ba..6427e250a 100644
--- a/tests/LageBuch.Persistence.Tests/MasterDataJsonTests.cs
+++ b/tests/LageBuch.Persistence.Tests/MasterDataJsonTests.cs
@@ -49,6 +49,40 @@ public void Parse_reads_every_category_from_a_full_file()
Assert.Equal("Land 1", max.CallSign);
}
+ // #995: optional, so every export written before it reads as "named by Funkrufname".
+ [Fact]
+ public void Trupp_typ_numbering_flag_is_read_written_and_defaults_to_off()
+ {
+ var set = Parse("""
+ {
+ "truppTypes": [
+ { "name": "CSA-Trupp", "memberCount": 3, "maxDurationMinutes": 20, "namedByNumber": true },
+ { "name": "Angriffstrupp", "memberCount": 2, "maxDurationMinutes": 30 }
+ ]
+ }
+ """);
+
+ Assert.Equal(new[] { true, false }, set.TruppTypes.Select(t => t.NamedByNumber));
+ Assert.Equal(set.TruppTypes, Parse(MasterDataJson.Serialize(set)).TruppTypes);
+ }
+
+ // #994: optional, so every export written before it reads as "not under Strahlenschutz".
+ [Fact]
+ public void Trupp_typ_strahlenschutz_flag_is_read_written_and_defaults_to_off()
+ {
+ var set = Parse("""
+ {
+ "truppTypes": [
+ { "name": "Strahlenschutztrupp", "memberCount": 3, "maxDurationMinutes": 30, "radiationMonitoring": true },
+ { "name": "Angriffstrupp", "memberCount": 2, "maxDurationMinutes": 30 }
+ ]
+ }
+ """);
+
+ Assert.Equal(new[] { true, false }, set.TruppTypes.Select(t => t.RadiationMonitoring));
+ Assert.Equal(set.TruppTypes, Parse(MasterDataJson.Serialize(set)).TruppTypes);
+ }
+
[Fact]
public void Parse_maps_the_legacy_flat_checklistTemplate_array_to_optional_aufbau_items()
{
@@ -620,11 +654,11 @@ public void Parse_maps_a_legacy_bare_string_trupp_type_the_way_the_store_migrati
new[]
{
new TruppType("Angriffstrupp", 2, 30),
- new TruppType("CSA-Trupp", 3, 20),
+ new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true),
new TruppType("LPA-Trupp", 2, 60),
// Trimmed and case-insensitive, matching what the old runtime rule accepted.
- new TruppType("csa-trupp", 3, 20),
+ new TruppType("csa-trupp", 3, 20, NamedByNumber: true),
},
set.TruppTypes);
}
@@ -652,7 +686,7 @@ public void A_legacy_file_keeps_the_einsatzzeiten_it_had_configured()
new[]
{
new TruppType("Angriffstrupp", 2, 25),
- new TruppType("CSA-Trupp", 3, 15),
+ new TruppType("CSA-Trupp", 3, 15, NamedByNumber: true),
new TruppType("LPA-Trupp", 2, 45),
},
set.TruppTypes);
diff --git a/tests/LageBuch.Persistence.Tests/MasterDataStoreTests.cs b/tests/LageBuch.Persistence.Tests/MasterDataStoreTests.cs
index 3884ec5ca..6d03311e9 100644
--- a/tests/LageBuch.Persistence.Tests/MasterDataStoreTests.cs
+++ b/tests/LageBuch.Persistence.Tests/MasterDataStoreTests.cs
@@ -665,9 +665,9 @@ public void A_pre_trupp_type_rules_database_widens_and_restores_what_the_old_rul
new[]
{
new TruppType("Angriffstrupp", 2, 30),
- new TruppType("CSA-Trupp", 3, 20),
+ new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true),
new TruppType("LPA-Trupp", 2, 60),
- new TruppType(" csa-trupp ", 3, 20),
+ new TruppType(" csa-trupp ", 3, 20, NamedByNumber: true),
},
set.TruppTypes);
}
@@ -680,7 +680,7 @@ public void The_trupp_type_migration_runs_once_and_never_overwrites_a_later_edit
// across every subsequent launch.
WriteLegacyTruppTypes("CSA-Trupp");
var migrated = MasterDataStore.GetOrCreate(_path);
- Assert.Equal(new TruppType("CSA-Trupp", 3, 20), Assert.Single(migrated.TruppTypes));
+ Assert.Equal(new TruppType("CSA-Trupp", 3, 20, NamedByNumber: true), Assert.Single(migrated.TruppTypes));
MasterDataStore.Save(_path, migrated with { TruppTypes = new[] { new TruppType("CSA-Trupp", 2, 45) } });
@@ -793,7 +793,7 @@ INSERT INTO md_settings (key, value) VALUES
new[]
{
new TruppType("Angriffstrupp", 2, 25),
- new TruppType("CSA-Trupp", 3, 15),
+ new TruppType("CSA-Trupp", 3, 15, NamedByNumber: true),
new TruppType("LPA-Trupp", 2, 45),
},
set.TruppTypes);
@@ -873,6 +873,72 @@ public void A_funkgruppe_stored_before_favourites_reads_back_as_no_favourite()
Assert.Equal(new TalkGroup("FW_MUSTER", "1000", TalkGroupKind.Tmo), Assert.Single(MasterDataStore.GetOrCreate(_path).TalkGroups));
}
+ // #995: a store from before the "Funkrufname aus Nummer" flag gets it on its CSA-Trupp once,
+ // so the brigade sees "CSA-Trupp 1" without touching the Stammdaten. Once only: a brigade that
+ // then switches it off keeps it off.
+ [Fact]
+ public void A_csa_trupp_from_before_the_numbering_flag_is_named_by_number_once()
+ {
+ using (var cn = new SqliteConnection($"Data Source={_path}"))
+ {
+ cn.Open();
+ using var cmd = cn.CreateCommand();
+ cmd.CommandText = """
+ CREATE TABLE md_trupp_types (
+ value TEXT NOT NULL,
+ member_count INTEGER NOT NULL DEFAULT 2,
+ max_duration_minutes INTEGER NOT NULL DEFAULT 30);
+ INSERT INTO md_trupp_types (value, member_count, max_duration_minutes) VALUES
+ ('Angriffstrupp', 2, 30),
+ (' csa-trupp ', 3, 20);
+ CREATE TABLE md_settings (key TEXT PRIMARY KEY, value INTEGER NOT NULL);
+ INSERT INTO md_settings (key, value) VALUES ('trupp_type_defaults_migrated', 1);
+ """;
+ cmd.ExecuteNonQuery();
+ }
+
+ SqliteConnection.ClearAllPools();
+
+ var set = MasterDataStore.GetOrCreate(_path);
+ Assert.Equal(new[] { false, true }, set.TruppTypes.Select(t => t.NamedByNumber));
+
+ MasterDataStore.Save(_path, set with
+ {
+ TruppTypes = set.TruppTypes.Select(t => t with { NamedByNumber = false }).ToArray(),
+ });
+ SqliteConnection.ClearAllPools();
+
+ Assert.All(MasterDataStore.GetOrCreate(_path).TruppTypes, t => Assert.False(t.NamedByNumber));
+ }
+
+ [Fact]
+ public void The_numbering_flag_survives_a_save_and_a_reload()
+ {
+ var set = MasterDataStore.GetOrCreate(_path) with
+ {
+ TruppTypes = new[] { new TruppType("Dekon-Trupp", 2, 30, NamedByNumber: true), new TruppType("Angriffstrupp") },
+ };
+
+ MasterDataStore.Save(_path, set);
+ SqliteConnection.ClearAllPools();
+
+ Assert.Equal(set.TruppTypes, MasterDataStore.GetOrCreate(_path).TruppTypes);
+ }
+
+ [Fact]
+ public void The_strahlenschutz_flag_survives_a_save_and_a_reload()
+ {
+ var set = MasterDataStore.GetOrCreate(_path) with
+ {
+ TruppTypes = new[] { new TruppType("Strahlenschutztrupp", 3, 30, RadiationMonitoring: true), new TruppType("Angriffstrupp") },
+ };
+
+ MasterDataStore.Save(_path, set);
+ SqliteConnection.ClearAllPools();
+
+ Assert.Equal(set.TruppTypes, MasterDataStore.GetOrCreate(_path).TruppTypes);
+ }
+
/// Writes a md_trupp_types in its pre-#398 shape: names only, no rules.
private void WriteLegacyTruppTypes(params string[] names)
{
diff --git a/tests/LageBuch.Persistence.Tests/StrahlenschutzPersistenceTests.cs b/tests/LageBuch.Persistence.Tests/StrahlenschutzPersistenceTests.cs
new file mode 100644
index 000000000..da9698adb
--- /dev/null
+++ b/tests/LageBuch.Persistence.Tests/StrahlenschutzPersistenceTests.cs
@@ -0,0 +1,139 @@
+using System.Diagnostics.CodeAnalysis;
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+using LageBuch.Domain.Time;
+using Microsoft.Data.Sqlite;
+
+namespace LageBuch.Persistence.Tests;
+
+/// The Strahlenschutzüberwachung of a Strahlenschutztrupp in the .lagebuch file (#994).
+public class StrahlenschutzPersistenceTests : IDisposable
+{
+ private readonly string _path = Path.Join(Path.GetTempPath(), $"rad-{Guid.NewGuid():N}.lagebuch");
+
+ private sealed class Clock : IClock
+ {
+ public DateTimeOffset Now { get; set; } = new(2026, 6, 22, 9, 0, 0, TimeSpan.FromHours(2));
+ }
+
+ public void Dispose()
+ {
+ SqliteConnection.ClearAllPools();
+ if (File.Exists(_path))
+ {
+ File.Delete(_path);
+ }
+ }
+
+ private static Incident IncidentWithStrahlenschutztrupp(out AtemschutzTrupp trupp)
+ {
+ var clock = new Clock();
+ var incident = Incident.Start(clock, new SessionOperator("Müller", "FFB 12/1"));
+ trupp = incident.AddScbaTrupp(
+ clock,
+ "Strahlenschutztrupp",
+ TruppMember.Crew("Müller", "Schmidt", "Huber"),
+ entryPressure: 300,
+ radiationMonitoring: true);
+ incident.AddScbaTrupp(clock, "Angriffstrupp", TruppMember.Crew("Bauer", "Klein"), entryPressure: 300);
+ return incident;
+ }
+
+ [Fact]
+ public void Numbers_readings_and_missing_dosimeters_round_trip()
+ {
+ var incident = IncidentWithStrahlenschutztrupp(out var trupp);
+ var full = new RadiationRecord("OSL 1", false, "EPD 7", false, "M 12", "PA 3", new DoseReading(0.125m, DoseUnit.MilliSievert));
+ var micro = new RadiationRecord("OSL 2", false, "EPD 8", false, alarmReading: new DoseReading(35m, DoseUnit.MicroSievert));
+ var missing = new RadiationRecord(oslDosimeterMissing: true, alarmDosimeterNumber: "EPD 9", alarmDosimeterMissing: true);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, full);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppmann, micro);
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.ZweiterTruppmann, missing);
+
+ IncidentRepository.Save(_path, incident);
+ var loaded = IncidentRepository.Load(_path);
+
+ var loadedTrupp = loaded.ScbaTrupps[0];
+ Assert.True(loadedTrupp.RadiationMonitoring);
+ Assert.Equal(new[] { full, micro, missing }, loadedTrupp.Members.Select(m => m.Radiation));
+
+ // An ordinary Trupp stays outside it: no flag, no records.
+ var ordinary = loaded.ScbaTrupps[1];
+ Assert.False(ordinary.RadiationMonitoring);
+ Assert.All(ordinary.Members, m => Assert.Null(m.Radiation));
+ }
+
+ // Registered but nothing entered yet: the empty record is not the same as no record.
+ [Fact]
+ public void An_empty_record_stays_an_empty_record()
+ {
+ var incident = IncidentWithStrahlenschutztrupp(out _);
+
+ IncidentRepository.Save(_path, incident);
+
+ Assert.All(IncidentRepository.Load(_path).ScbaTrupps[0].Members, m => Assert.Equal(RadiationRecord.Empty, m.Radiation));
+ }
+
+ // A .lagebuch is a file someone handed over: an implausible value costs that value, never the
+ // whole Einsatz.
+ [Theory]
+ [InlineData("'abc'", 0)]
+ [InlineData("'-1'", 0)]
+ [InlineData("'1e9'", 0)]
+ [InlineData("'1.5'", 9)]
+ public void An_unreadable_reading_in_a_handed_over_file_is_dropped_not_fatal(string doseSql, int unit)
+ {
+ var incident = IncidentWithStrahlenschutztrupp(out _);
+ IncidentRepository.Save(_path, incident);
+ Exec($"UPDATE scba_trupp_members SET dose_value = {doseSql}, dose_unit = {unit}, osl_number = '{new string('9', 80)}' WHERE has_radiation = 1;");
+
+ var member = IncidentRepository.Load(_path).ScbaTrupps[0].Members[0];
+
+ Assert.Null(member.Radiation?.AlarmReading);
+ Assert.Equal(RadiationRecord.MaxNumberLength, member.Radiation?.OslDosimeterNumber?.Length);
+ }
+
+ [Fact]
+ public void A_reading_beside_a_missing_alarmdosimeter_is_dropped_not_fatal()
+ {
+ var incident = IncidentWithStrahlenschutztrupp(out _);
+ IncidentRepository.Save(_path, incident);
+ Exec("UPDATE scba_trupp_members SET alarm_missing = 1, dose_value = '0.5', dose_unit = 0 WHERE has_radiation = 1;");
+
+ var record = IncidentRepository.Load(_path).ScbaTrupps[0].Members[0].Radiation;
+
+ Assert.True(record?.AlarmDosimeterMissing);
+ Assert.Null(record?.AlarmReading);
+ }
+
+ // A file from before #994 reads back with no Trupp under Strahlenschutzüberwachung.
+ [Fact]
+ public void A_v45_file_gains_the_columns_and_still_loads()
+ {
+ var incident = IncidentWithStrahlenschutztrupp(out _);
+ IncidentRepository.Save(_path, incident);
+ Exec("UPDATE schema_version SET version = 45; "
+ + "ALTER TABLE scba_trupps DROP COLUMN radiation_monitoring; "
+ + "ALTER TABLE scba_trupp_members DROP COLUMN has_radiation; "
+ + "ALTER TABLE scba_trupp_members DROP COLUMN dose_value;");
+
+ var loaded = IncidentRepository.Load(_path);
+
+ Assert.False(loaded.ScbaTrupps[0].RadiationMonitoring);
+ Assert.All(loaded.ScbaTrupps[0].Members, m => Assert.Null(m.Radiation));
+ }
+
+ [SuppressMessage("Security", "CA2100", Justification = "Test-only: the statement is built from this test's own constants to play a hostile or older file.")]
+ private void Exec(string sql)
+ {
+ using (var cn = new SqliteConnection($"Data Source={_path}"))
+ {
+ cn.Open();
+ using var cmd = cn.CreateCommand();
+ cmd.CommandText = sql;
+ cmd.ExecuteNonQuery();
+ }
+
+ SqliteConnection.ClearAllPools();
+ }
+}
diff --git a/tests/LageBuch.Sync.Tests/CommandSerializationTests.cs b/tests/LageBuch.Sync.Tests/CommandSerializationTests.cs
index 425e32dba..8bff7d46b 100644
--- a/tests/LageBuch.Sync.Tests/CommandSerializationTests.cs
+++ b/tests/LageBuch.Sync.Tests/CommandSerializationTests.cs
@@ -77,6 +77,24 @@ public class CommandSerializationTests
new SetScbaSafetyTruppCommand(Guid.NewGuid(), Guid.NewGuid()),
new SetScbaSafetyTruppCommand(Guid.NewGuid(), null),
new ChangeScbaTruppTypeCommand(Guid.NewGuid(), "Angriffstrupp", 30, 10),
+ new AddScbaTruppCommand(
+ "Strahlenschutztrupp",
+ new[]
+ {
+ new TruppMemberDto(TruppRole.Truppfuehrer, "Müller", new RadiationRecordDto("OSL 1", false, "EPD 7", false, "M 2", "PA 3")),
+ new TruppMemberDto(TruppRole.Truppmann, "Schmidt", new RadiationRecordDto(null, true, "EPD 8", false, null, null)),
+ },
+ "HLF 1",
+ null,
+ 30,
+ 60,
+ 10,
+ EntryPressure: 300,
+ RadiationMonitoring: true),
+ new RecordScbaRadiationCommand(
+ Guid.NewGuid(), TruppRole.Truppmann, new RadiationRecordDto("OSL 1", false, "EPD 7", false, null, null, 0.125m, DoseUnit.MilliSievert)),
+ new RecordScbaRadiationCommand(
+ Guid.NewGuid(), TruppRole.ZweiterTruppmann, new RadiationRecordDto("OSL 1", false, "EPD 7", true, null, null)),
new SetIncidentNumberCommand("B 1.2 260812 001"),
new SetKeywordCommand("Brand 2"),
new SetAddressCommand("Hauptstraße 1", "Bezirk 2"),
diff --git a/tests/LageBuch.Sync.Tests/StrahlenschutzSyncTests.cs b/tests/LageBuch.Sync.Tests/StrahlenschutzSyncTests.cs
new file mode 100644
index 000000000..310ab205c
--- /dev/null
+++ b/tests/LageBuch.Sync.Tests/StrahlenschutzSyncTests.cs
@@ -0,0 +1,116 @@
+using LageBuch.Domain;
+using LageBuch.Domain.Atemschutz;
+
+namespace LageBuch.Sync.Tests;
+
+/// The Strahlenschutzüberwachung of a Strahlenschutztrupp across the wire (#994).
+public class StrahlenschutzSyncTests
+{
+ private static Incident NewIncident(FixedClock clock) =>
+ Incident.Start(clock, new SessionOperator("Host", "FFB 1"), keyword: null, incidentNumber: null);
+
+ private static void ApplyOverWire(SyncCommand command, Incident incident, FixedClock clock) =>
+ CommandApplier.Apply(SyncJson.Deserialize(SyncJson.Serialize(command)), incident, clock);
+
+ private static AtemschutzTrupp AddOverWire(Incident incident, FixedClock clock)
+ {
+ ApplyOverWire(
+ new AddScbaTruppCommand(
+ "Strahlenschutztrupp",
+ new[] { new TruppMemberDto(TruppRole.Truppfuehrer, "Müller"), new TruppMemberDto(TruppRole.Truppmann, "Schmidt") },
+ "HLF 1",
+ null,
+ 30,
+ 60,
+ 10,
+ EntryPressure: 300,
+ RadiationMonitoring: true),
+ incident,
+ clock);
+ return incident.ScbaTrupps[^1];
+ }
+
+ [Fact]
+ public void A_client_registers_a_strahlenschutztrupp_on_the_host()
+ {
+ var clock = new FixedClock();
+ var incident = NewIncident(clock);
+
+ var trupp = AddOverWire(incident, clock);
+
+ Assert.True(trupp.RadiationMonitoring);
+ Assert.All(trupp.Members, m => Assert.Equal(RadiationRecord.Empty, m.Radiation));
+ }
+
+ [Fact]
+ public void A_client_records_a_reading_on_the_host()
+ {
+ var clock = new FixedClock();
+ var incident = NewIncident(clock);
+ var trupp = AddOverWire(incident, clock);
+
+ ApplyOverWire(
+ new RecordScbaRadiationCommand(
+ trupp.Id, TruppRole.Truppmann, new RadiationRecordDto("OSL 1", false, "EPD 7", false, "M 2", "PA 3", 35m, DoseUnit.MicroSievert)),
+ incident,
+ clock);
+
+ Assert.Equal(
+ new RadiationRecord("OSL 1", false, "EPD 7", false, "M 2", "PA 3", new DoseReading(35m, DoseUnit.MicroSievert)),
+ trupp.Members[1].Radiation);
+ }
+
+ // A sync peer on a shared LAN is untrusted: what the domain refuses, the host refuses.
+ [Theory]
+ [InlineData(80, 1.0, 0)]
+ [InlineData(5, -1.0, 0)]
+ [InlineData(5, 1.0, 9)]
+ public void The_host_refuses_a_record_the_domain_refuses(int numberLength, double dose, int unit)
+ {
+ var clock = new FixedClock();
+ var incident = NewIncident(clock);
+ var trupp = AddOverWire(incident, clock);
+ var hostile = new RadiationRecordDto(
+ new string('9', numberLength), false, "EPD 7", false, null, null, (decimal)dose, (DoseUnit)unit);
+
+ Assert.ThrowsAny(
+ () => ApplyOverWire(new RecordScbaRadiationCommand(trupp.Id, TruppRole.Truppfuehrer, hostile), incident, clock));
+ Assert.Equal(RadiationRecord.Empty, trupp.Members[0].Radiation);
+ }
+
+ [Fact]
+ public void A_value_without_a_unit_is_refused()
+ {
+ var dto = new RadiationRecordDto("OSL 1", false, "EPD 7", false, null, null, 1m);
+
+ Assert.Throws(() => dto.ToRecord());
+ }
+
+ [Fact]
+ public void The_snapshot_carries_the_flag_and_every_record()
+ {
+ var clock = new FixedClock();
+ var incident = NewIncident(clock);
+ var trupp = AddOverWire(incident, clock);
+ var record = new RadiationRecord("OSL 1", false, "EPD 7", true, "M 2", "PA 3");
+ incident.RecordScbaRadiation(trupp.Id, TruppRole.Truppfuehrer, record);
+
+ var snapshot = SyncJson.Deserialize(SyncJson.Serialize(SnapshotMapper.ToSnapshot(incident)));
+ var mirrored = SnapshotMapper.FromSnapshot(snapshot).ScbaTrupps[0];
+
+ Assert.True(mirrored.RadiationMonitoring);
+ Assert.Equal(new[] { record, RadiationRecord.Empty }, mirrored.Members.Select(m => m.Radiation));
+ }
+
+ // A client reads a host's snapshot leniently: one bad value costs that value, not the Einsatz.
+ [Fact]
+ public void A_hostile_snapshot_record_is_read_leniently()
+ {
+ var dto = new RadiationRecordDto(new string('9', 80), false, "EPD 7", true, null, null, 5m, DoseUnit.MilliSievert);
+
+ var record = dto.ToUntrustedRecord();
+
+ Assert.Equal(RadiationRecord.MaxNumberLength, record.OslDosimeterNumber?.Length);
+ Assert.Null(record.AlarmReading);
+ }
+}
diff --git a/tests/LageBuch.Sync.Tests/VersionHandshakeTests.cs b/tests/LageBuch.Sync.Tests/VersionHandshakeTests.cs
index a2fdc98f1..7c00bea1c 100644
--- a/tests/LageBuch.Sync.Tests/VersionHandshakeTests.cs
+++ b/tests/LageBuch.Sync.Tests/VersionHandshakeTests.cs
@@ -385,7 +385,7 @@ public void The_alarm_place_names_raise_the_protocol_but_not_the_floor()
// 41 adds dispatchPlaceNames to /masterdata. A peer at 40 drops the key and only loses the
// pre-ticked Einsatzmittel of an alarm, so a 40 and a 41 still connect.
Assert.InRange(SyncProtocol.ProtocolVersion, 41, int.MaxValue);
- Assert.InRange(SyncProtocol.MinimumProtocolVersion, int.MinValue, 40);
+ Assert.InRange(SyncProtocol.MinimumProtocolVersion, 40, int.MaxValue);
}
[Fact]
@@ -394,7 +394,7 @@ public void The_upper_alarm_of_a_falling_gas_raises_the_protocol_but_not_the_flo
// 42 adds an optional upperAlarm to every gas definition (#927). A peer at 41 drops it and
// only loses the enrichment colour of its O2, so a 41 and a 42 still connect.
Assert.InRange(SyncProtocol.ProtocolVersion, 42, int.MaxValue);
- Assert.InRange(SyncProtocol.MinimumProtocolVersion, int.MinValue, 40);
+ Assert.InRange(SyncProtocol.MinimumProtocolVersion, 40, int.MaxValue);
}
[Fact]
@@ -402,7 +402,27 @@ public void The_fahrzeugkennungen_raise_the_protocol_but_not_the_floor()
{
// 43 adds vehicleTypeCodes to /masterdata. A peer at 42 drops the key and only types its
// new vehicles by hand, so a 42 and a 43 still connect.
- Assert.Equal(43, SyncProtocol.ProtocolVersion);
- Assert.Equal(40, SyncProtocol.MinimumProtocolVersion);
+ Assert.InRange(SyncProtocol.ProtocolVersion, 43, int.MaxValue);
+ Assert.InRange(SyncProtocol.MinimumProtocolVersion, 40, int.MaxValue);
+ }
+
+ [Fact]
+ public void The_numbered_trupp_typ_raises_the_protocol_but_not_the_floor()
+ {
+ // 44 adds namedByNumber to a Trupp-Typ in /masterdata (#995). A peer at 43 drops the key and
+ // offers its free Funkrufname box, while the name itself travels in the existing callSign,
+ // so a 43 and a 44 still connect.
+ Assert.InRange(SyncProtocol.ProtocolVersion, 44, int.MaxValue);
+ Assert.InRange(SyncProtocol.MinimumProtocolVersion, 40, int.MaxValue);
+ }
+
+ [Fact]
+ public void The_strahlenschutz_trupp_raises_the_protocol_and_the_floor_to_forty_five()
+ {
+ // 45 lets a client send recordScbaRadiation (#994), which a host at 44 does not know, and
+ // addScbaTrupp carries radiationMonitoring, which a host at 44 would drop -- registering the
+ // Trupp outside the Überwachung. A 44 and a 45 must not connect.
+ Assert.Equal(45, SyncProtocol.ProtocolVersion);
+ Assert.Equal(45, SyncProtocol.MinimumProtocolVersion);
}
}